Components Shipped 

Carefully check the contents of the carton for damage that might have 
occurred in transit.  Do not discard the carton or packing material until all 
components have been checked against the following component list and the 
equipment has been installed and tested. 
 
As shipped, the carton should contain the following: 
 

Part Number 

Description 

35001 

Goldfisch Fat Extraction Apparatus 

 

 

35051 

Beakers, 100 cc (12) 

 

 

35049 

Sample Tubes (6) 

 

 

35048 

Reclaiming Tubes (6) 

 

 

35050 

Extraction Thimbles (6) 

 

 

35052 

Condenser Gaskets (6) 

 

 

35191 

Wave Washer – Beaker Seal (6) 

 

 

35054 

Ring, Beaker Retainer (6) 

 

 

35185 

Assembly, Heater Cover (6) 

 

 

35181 

Instruction Manual (this document) 

 

 

Содержание 3500100

Страница 1: ...Goldfisch Fat Extraction Apparatus Models 3500100...

Страница 2: ...30 a m and 5 30 p m Central Standard Time Part 3518100 Rev L ECO L123 Warranty Labconco Corporation provides a warranty to the original buyer for the repair or replacement of parts and reasonable labo...

Страница 3: ...n 2 CHAPTER 2 INSTALLATION 4 Preparation 4 Location 4 Utility Connections 4 Initial Start Up and Check Out 4 Gasket Assembly 5 CHAPTER 3 NORMAL OPERATION ROUTINE MAINTENANCE 6 Summary of Operation 6 P...

Страница 4: ...have been checked against the following component list and the equipment has been installed and tested As shipped the carton should contain the following Part Number Description 35001 Goldfisch Fat Ex...

Страница 5: ...er to the condenser heads Water exits through the water control valve located on the upper left hand portion of the unit And flows through the manifold assembly depositing cool water in the condenser...

Страница 6: ...Chapter 1 Introduction Product Service 1 800 522 7658 3 Figure 1...

Страница 7: ...ood with proper airflow to handle the extremely flammable solvents that are used during the Goldfisch Extractor s normal operation Utility Connections 1 Once the unit has been placed in its final loca...

Страница 8: ...ing parts package which should be taped to the unit Assemble the gasket wave washer retaining ring and glassware according to assembly drawing instructions as shown in Appendix A Hand tighten the reta...

Страница 9: ...tor Actual test methods sample preparation solvent choices etc are determined by official methods of the A O A C and should be referred to in all cases 1 1 Turn on cold water supply Check visual flow...

Страница 10: ...witch should be loaded with a beaker of solvent or water to load the heater and increase its service life 10 Pre heating the heaters for about 8 to 10 minutes prior to starting samples will reduce wai...

Страница 11: ...h the loss reported as the ether extract Official methods should be referred to for specific test procedure of the indirect method in all cases Maintenance All of the parts contained in the operating...

Страница 12: ...5163 1 Switch infinite control 35046 Pkg of 6 Beaker glass Pyrex tall form 5 high 35053 Pkg of 6 Beaker glass Pyrex 100 cc 3 1 4 high 35054 Ring beaker 35059 Pkg of 6 Extraction thimble 22 x 80 mm 350...

Страница 13: ...Appendix A Replacement Parts Product Service 1 800 522 7658 10...

Страница 14: ...Product Service 1 800 522 7658 11 A Ap pp pe en nd di ix x B B D Di im me en ns si io on ns s 35 7 26 9 9...

Страница 15: ...No 35001 operates on 115 volts 50 60 Hz max at 5 2 amps It is shipped complete with power cord and grounded 3 wire plug Standard features are as follows 1 Main power on off 2 Full range variable heat...

Страница 16: ...Product Service 1 800 522 7658 13 A Ap pp pe en nd di ix x D D W Wi ir ri in ng g D Di ia ag gr ra am m...

Отзывы: