
10
PDX3000
Quick Start Guide
11
1. Introduction
1.1 Welcome
T
hank
you
for
choosing
a
Lab.gruppen
PD
X
Series
product.
T
his
manua
l
provides
a
comprehensive
guide
to
the
features
and
functiona
l
ity
of
PD
X
Series
mode
l
PD
X
3000
and
PD
X
2000
amp
l
ifi
ers.
We
high
l
y
recommend
you
read
through
this
manua
l
in
its
entirety
to
become
fu
ll
y
acquainted
with
confi
guration
options
and
protection
circuitry.
As
you
become
thorough
l
y
fami
l
iar
with
a
ll
aspects
of
operation,
you
may
l
earn
of
features
or
options
that
wi
ll
aff
ect
your
choices
on
amp
l
ifi
er
modes
or
l
oudspeaker
system
confi
guration.
Lab.gruppen
PD
X
Series
power
amp
l
ifi
ers
are
designed
and
bui
l
t
with
competitive
price
and
good
performance
and
protection
features
in
mind.
A
l
though
the
PD
X
Series
features
a
competitive
price,
each
amp
l
ifi
er
draws
on
the
engineering
that
has
made
Lab.gruppen
the
benchmark
of
qua
l
ity
for
touring
concert
systems:
exceptiona
l
sonic
performance,
rugged
construction,
proven
re
l
iabi
l
ity,
and
protection
features
that
anticipate
every
unwe
l
come
possibi
l
ity
–
that
is
the
core
of
the
“
Show
must
go
on
”
design
phi
l
osophy
that
every
Lab.gruppen
product
is
created
with,
with
a
we
ll
matched
feature
set
per
product
range
depending
on
the
expected
app
l
ication.
T
his
manua
l
was
created
for
the
PD
X
Series
3000
and
2000
amp
l
ifi
er
mode
l
s.
Any
references
to
“
PD
X
Series
”
in
this
manua
l
refer
to
a
ll
mode
l
s
in
the
range.
1.2 Features
Y
our
new
PD
X
Series
amp
l
ifi
er
incorporates
a
number
of
sophisticated
techno
l
ogies
–
many
of
them
proprietary
to
Lab.gruppen
–
that
ensure
the
best
possib
l
e
performance
and
years
of
re
l
iab
l
e
operation.
F
ami
l
iarizing
yourse
l
f
with
these
techno
l
ogies
wi
ll
prove
inva
l
uab
l
e
in
setting
up
and
optimizing
your
l
oudspeaker
system.
1.3 Class D output stage
A
ll
PD
X
Series
amp
l
ifi
ers
emp
l
oy
our
unique
I
D
EE
A
C
l
ass
D
output
stage
that
is
idea
ll
y
matched
to
the
rated
power
output.
T
o
provide
fl
exibi
l
ity,
each
channe
l
off
ers
suffi
cient
vo
l
tage
swing
and
current
capacity
to
drive
l
oads
in
any
impedance
without
any
additiona
l
confi
guration.
I
n
order
to
have
l
ow
therma
l l
osses
as
we
ll
as
a
high
vo
l
tage
swing,
the
design
is
based
on
a
permanent
l
y
bridged
output.
1.4 Protection and performance optimization
Appropriate
and
re
l
iab
l
e
power
amp
l
ifi
cation
is
vita
l
to
any
audio
system.
I
nadequate
or
fau
l
ty
power
amp
l
ifi
ers
cou
l
d
cause
damage
to
l
oudspeakers,
or
in
some
cases
to
the
power
amp
l
ifi
ers
themse
l
ves.
T
o
prevent
damage
or
service
interruptions,
PD
X
Series
amp
l
ifi
ers
off
er
advanced
features
to
protect
both
interna
l
circuits
and
connected
l
oads.
T
hese
features
are
part
of
the
Lab.gruppen
phi
l
osophy
“
Show
must
go
on
”
.
Standard
on
the
PD
X
Series
protection
features
inc
l
ude:
•
CP
L
(C
urren
t P
ea
k
Limi
t
er
)
ensures
that
the
amp
l
ifi
er’s
output
does
not
exceed
the
safe
current
hand
l
ing
parameters
of
the
amp
l
ifi
er
components.
•
T
em
p
era
t
ure
p
ro
t
ec
t
ion
ensures
that
the
amp
l
ifi
er
wi
ll
not
be
damaged
by
exceeding
therma
l l
imits.
T
he
RD
Y
L
E
D
fl
ashes
orange
when
the
amp
l
ifi
er
approaches
therma
l l
imits
to
a
ll
ow
user
action
before
protective
muting
engages.
•
DC p
ro
t
ec
t
ion
ensures
destructive
DC
signa
l
s
wi
ll
not
appear
at
the
amp
l
ifi
er
outputs.
I
f
such
conditions
occur
an
interna
l
fuse
opens.
•
RS
L
(R
ai
l S
ensing
Limi
t
er
)
is
app
l
ied
to
avoid
distortion
at
the
se
l
ected
vo
l
tage
l
imit
thresho
l
d
and
to
avoid
hitting
the
rai
l
if
it
has
sagged
be
l
ow
the
confi
gured
thresho
l
d.
Limiting
a
l
so
may
be
app
l
ied
when
maximum
output
current
has
been
reached
or
when
the
mains
vo
l
tage
is
too
l
ow
to
maintain
required
rai
l
vo
l
tage.
Limiting
activity
is
shown
by
the
front
pane
l
Limiter
L
E
D
1.5 DSP features and PDX controller software
PD
X
series
feature
a
comprehensive
DSP
functions
such
as
crossover,
parametric
E
Q,
de
l
ay,
l
imiter,
dynamic
E
Q
and
input
mixing,
making
the
PD
X
series
suitab
l
e
for
a
broad
range
of
insta
ll
ed
and
touring
app
l
ications.
T
he
PD
X
series
can
be
contro
ll
ed
through
the
usage
of
front
pane
l
or
PD
X
Contro
ll
er
software
by
connecting
to
a
PC
with
USB.
1.6 Unpacking and visual checks
E
very
Lab.gruppen
amp
l
ifi
er
is
carefu
ll
y
tested
and
inspected
before
l
eaving
the
factory
and
shou
l
d
arrive
in
perfect
condition.
I
f
any
damage
is
discovered,
p
l
ease
notify
the
shipping
carrier
immediate
l
y.
Save
the
packing
materia
l
s
for
the
carrier’s
inspection
and
for
any
future
shipping.
1.7 Cooling
T
he
PD
X
Series
devices
use
a
forced-air
coo
l
ing
system
with
front
to
rear
airfl
ow,
a
ll
owing
high
continuous
power
l
eve
l
s
without
therma
l
prob
l
ems.
P
l
ease
ensure
that
there
is
suffi
cient
space
in
the
front
and
rear
of
each
amp
l
ifi
er
to
a
ll
ow
free
fl
ow
of
air,
no
doors
or
covers
shou
l
d
be
mounted
either
in
the
front
or
rear
of
the
amp
l
ifi
ers.
Amp
l
ifi
ers
may
be
stacked
direct
l
y
on
top
of
each
other
with
no
spacing,
though
some
spacing
may
enab
l
e
more
convenient
insta
ll
ation
of
rear
cab
l
ing.
F
it
so
l
id
b
l
anks
(not
venti
l
ation
b
l
anks)
to
unused
rack
spaces
to
ensure
eff
ective
air
circu
l
ation.
Leaving
gaps
in
between
items
of
equipment
degrades
the
eff
ectiveness
of
forced-air
coo
l
ing.
1.8 Operating voltage
A
l
ways
connect
your
PD
X
amp
l
ifi
er
to
the
vo
l
tage
specifi
ed
on
the
rear
of
the
device.
Connecting
the
amp
to
an
incorrect
vo
l
tage
can
permanent
l
y
damage
your
amp.
•
USA
/
Canada
/
Japan
=
100-120
V
~
,
50/60
H
z
•
UK
/
Austra
l
ia
/
E
urope
/
Korea
/
China
220-240
V
~
,
50/60
H
z
T
he
l
ocking
IE
C
receptac
l
e
on
the
rear
pane
l
accepts
the
supp
l
ied
IE
C
cord
which
terminates
in
a
connector
appropriate
for
the
country
of
sa
l
e.
2. Control
2.1 Front Panel
T
he
fo
ll
owing
indicators
and
contro
l
s
are
avai
l
ab
l
e
on
the
front
pane
l
(
F
ig.
1):
F
ig.
1:
PD
X
3000
F
ront
Pane
l
(1)
RACK
E
ARS
secure
the
unit
into
a
rack
using
four
attaching
screws
and
washers
(fasteners
not
inc
l
uded).
T
he
height
requires
two
rack
units.
(2)
V
E
NTI
L
ATION
openings
a
ll
ow
front-to-rear
air
circu
l
ation
to
prevent
overheating.
(3)
INPUT CONTRO
L
S
adjust
the
input
l
eve
l
for
each
channe
l
.
T
o
attenuate
the
input
signa
l
,
rotate
the
knobs
counter-c
l
ockwise.
(4)
PROC
E
SS
button
steps
through
the
DSP
processing
modu
l
es.
(5)
S
E
TUP
button
accesses
basic
device
confi
guration
functions
such
as
presets,
pane
l l
ock,
device
name
and
screen
contrast.
(6)
LE
V
EL
LE
D
s
disp
l
ay
the
signa
l l
eve
l
for
each
channe
l
.
Reduce
the
input
gain
if
a
channe
l
’s
red
L
I
M
L
E
D
l
ights
up
continuous
l
y.
(7)
L
CD SCR
EE
N
disp
l
ays
the
current
DSP
modu
l
e
and
parameter
settings.
(8)
UP/DOWN
buttons
navigates
through
menus
by
stepping
up/down
through
parameters.
(9)
E
XIT
button
acts
as
a
“
back
”
button
and
takes
you
back
one
step
in
the
menu
hierarchy
per
press.
(10)
S
ELE
CT
encoder
knob
togg
l
es
between
Graphic
and
E
dit
modes
(when
pressed)
and
changes
parameter
va
l
ues
(when
rotated).
(11)
POW
E
R
button
turns
the
amp
l
ifier
on
and
off.
(1)
(2)
(6)
(7)
(10)
(11)
(8)
(5)
(4)
(9)
(3)
Содержание PDX3000
Страница 1: ...Quick Start Guide PDX3000 3000 Watt Two Channel Amplifier with DSP Control A54 00002 35423...
Страница 26: ...50 PDX3000 Quick Start Guide 51...
Страница 27: ......