Lab.gruppen C Series C 10 4X Скачать руководство пользователя страница 9

   

C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual  

9

5.1  unpacking

Carefully open the shipping carton and check for any 

noticeable damage. Every Lab.gruppen amplifier is 

tested and inspected before leaving the factory and 

should arrive in perfect condition. If any damage 

is discovered, please notify the shipping company 

immediately. Only the consignee may institute a 

claim with the carrier for damage incurred during 

shipping. Save the carton and packing materials for 

the carrier’s inspection. Should you ever need to 

ship the amplifier, always use the original packaging 

materials.

5.2  Mounting

The amplifier is two rack units high (2U) and will fit 

into a standard EIA 19” rack. The depth is 343 mm 

(13.5”). The weight is approximately 8.5 kg (18.75 

lbs.) depending on model type.

Free airflow from front-to-rear of the amplifier must 

be possible. Therefore, no doors or rack-lids should 

be mounted in front of or behind the amplifiers.

Amplifiers may be stacked directly on top of each 

other. There is no need for spacing in between units, 

though this might enable more convenient installation 

of cabling on the rear panel. 

It is recommended that rear supports be mounted 

for maximum long-term stability.

5.3  Cooling 

The  amplifier  uses  a  forced-air  cooling  system 

with air flow from front-to-rear, maintaining a low  

operating temperature within defined limits. Front-to-

rear airflow is preferred as cooler air is present at the 

front in nearly all installed applications. (This allows 

higher continuous power levels without encountering 

thermal problems.) Never attempt to reverse the 

airflow. The amplifier modules require a pressure 

chamber between the fans and heatsink, and this 

effect functions only in one direction.

Make sure that there is an adequate air supply in front 

of the amplifier, and that the rear of the amplifier has 

sufficient space to allow the exhaust to escape. If 

the amplifier is rack-mounted, do not use covers or 

doors on the front or rear of the rack.

 

Should  a  heat  sink  overheat,  the  temperature 

sensing circuits will mute the overheating channel. 

If  the  power  supply  overheats,  another  sensing 

circuit will mute all output channels until the power  

supply cools to safe operating temperature. An early  

warning before shut down will be indicated on the 

front-panel LEDs, and a warning will be sent through 

the NomadLink network.

Always make sure that the dust filters behind the 

detachable front-panel are clean to ensure maximum 

possible airflow. 

If the amplifier malfunctions due to dirty 

dust filters, any required repairs are not 

covered by the warranty.

To calculate the maximum heat emission value, when 

installing the amplifiers in rooms with an air-conditio-

ning system, please refer to the Current Draw and 

Thermal Dissapation specifications provided in the 

Appendix section.

5.4  Operating voltage 

All C…X amplifiers have a universal power supply that 

accepts mains voltages from 100-240 V (+/- 10%) @ 

50 or 60 Hz. An IEC male receptacle is provided on 

the rear panel of all amplifiers. The IEC cord included 

with each amplifier has a male plug appropriate for 

the power receptacles in the country in which it was 

sold. If substituting a different IEC mains cord for 

use in another country, use only a cord that meets 

or exceeds the power rating of the originally supplied 

cord.

Once  a  suitable  AC  supply  is  connected,  the  

amplifier can be turned on using the front-panel 

power switch. The amplifier then goes through a 

soft-start sequence as it self-checks its circuits. The 

fans will blow at high speed before dropping to idle, 

and the “power” LED will illuminate.

Inrush power is controlled and limited during “soft-

start”, enabling multiple amplifiers to be powered 

up simultaneously with no danger of overloading the 

mains power circuit.

INsTALLATION  5

Содержание C Series C 10 4X

Страница 1: ...Rev 1 0 2 Operation Manual C Series Dedicated Installation Amplifiers C 20 8X C 10 8X C 10 4X C 5 4X Item no OM CXS...

Страница 2: ...VPL 7 4 2 4 Protection and performance optimization 7 4 2 5 GPIO facilities and 35 Hz HPF 7 4 2 6 NomadLink Ethernet control and monitoring network 8 5 installation 9 5 1 Unpacking 9 5 2 Mounting 9 5...

Страница 3: ...20 7 6 2 Very High Frequency VHF protection 20 7 6 3 DC protection 21 7 6 4 High impedance warning open load 21 7 6 5 Low impedance protection short circuit 21 7 6 6 Temperature protection 21 7 6 7 Po...

Страница 4: ...ified by the manufacturer 11 The unit is intended to use in a 19 rack Follow the mounting instructions When a rack on wheels is used use caution when moving the loaded rack to avoid injury from tippin...

Страница 5: ...terference to radio or television reception which can be deter mined by turning the equipment on and off the user is encouraged to try to correct the interference by one or more of the following measu...

Страница 6: ...e or constant voltage 70 Vrms 100 V peak mode NomadLink an easy to use network for monitoring and control is implemented as a standard feature on all C Series amplifiers Although C Series features and...

Страница 7: ...ure protection ensures that the amplifier will not be damaged by exceeding thermal limits PAL Power Average Limiter limits the maximum average power consumption according to the power supply and mains...

Страница 8: ...d for easy system setup There is no need to create a star topology using many switches as with for example an Ethernet system Individual amplifier addresses do not need to be manually entered you will...

Страница 9: ...amplifier and that the rear of the amplifier has sufficient space to allow the exhaust to escape If the amplifier is rack mounted do not use covers or doors on the front or rear of the rack Should a h...

Страница 10: ...r terminal on the C Series amplifiers The signal ground is always floating via a resistor to chassis and therefore the grounding system is automatic In the interests of safety never disconnect the ear...

Страница 11: ...C Series C 20 8X C 10 8X C 10 4X and C 5 4X Operation Manual 11 11 This PAGE INTENTIONALLY LEFT BLANK...

Страница 12: ...ote switch is off it is not possible to switch amplifier power on or off using NomadLink network control 6 1 2 Front panel LED s The front panel LED area includes the following indicators per channel...

Страница 13: ...ODE HP 35H Z VPL CH F MODE HP 35H Z VPL CH G MODE HP 35H Z VPL CH H MODE HP 35H Z VPL CH B MODE HP 35H Z VPL CH C MODE HP 35H Z VPL CH D MODE HP 35H Z GAIN 38dB 35dB 32dB 29dB VPL 100V 70Vrms 63V 45V...

Страница 14: ...45 equipped cables US National Differences cl 16 3 requires that NomadLink network cables must be rated VW 1 The OUT port from the NLB 60E must be connected to the IN port of the first amplifier The O...

Страница 15: ...H E CH F CH G CH H BALANCED INPUTS BRIDGE A B BRIDGE E F VPL CH A MODE HP 35H VPL CH E MODE HP 35H VPL CH F MODE HP 35H VPL CH G MODE HP 35H VPL CH H MODE HP 35H VPL CH B MODE HP 35H VPL CH C MODE HP...

Страница 16: ...utput is maintained within the design limits of the amplifier The adjustable VPL Voltage Peak Limiter sets the maximum channel output voltage and therefore also the maximum channel output power Four 4...

Страница 17: ...ided at each channel output for connection of the speakers Make sure that the speaker cables are connected correctly and tightly and that accurate polarity is maintained to all speakers in the system...

Страница 18: ...ition indicating 10 dB Use your fingers or a screwdriver to adjust the potentiometers If the level control is used to attenuate to a lower level than the headroom relative to input sensitivity AND the...

Страница 19: ...the front panel Warnings also are shown in the DeviceControl software s GUI A steadily illuminated orange CPL LED indicates a short circuit situation or very low impedance The output will mute for 6 s...

Страница 20: ...ntact 1 kOhm 7 5 4 NomadLink disable switch The DIP switch labeled GPI NomadLink com pletely disables the amplifier s connectivity to the NomadLink network 7 6 Protection faults and warnings 7 6 1 Int...

Страница 21: ...by muting the output signal and bypassing the circuits Indication of this fault is a constant orange illumination of the Current Peak Limiter CPL LED on the front panel The protection will sequence a...

Страница 22: ...th a pre set delay between each amplifier s start up 7 7 Front panel monitoring and adjustments 7 7 1 Level indicators Five LED indicators per channel are contained on C X amplifier front panels Figur...

Страница 23: ...ance Warning and Fault indicators Power on off green indicates that mains power is switched on NomadLink blue indicates that the network is connected The NomadLink LED will light up even before the ma...

Страница 24: ...tive even when the amplifier has mains power disconnected or is not yet powered up This is due to the fact that the NomadLink network is solely powered via phantom power generated by the NLB 60E Shoul...

Страница 25: ...her or where groups of amplifiers within a single subnet with up to 60 units will be installed with a distance in between these general rules applying to Ethernet cabling limitations may be considered...

Страница 26: ...Windows PC which connects via Ethernet to the NLB 60E DeviceControl provides comprehensive monitoring of amplifier status as well as control of amplifier power on off and individual channel mute and...

Страница 27: ...imum cable length in between any two devices may not exceed 300 meters 980 feet In a non closed loop daisy chained subnet the maximum cable length is 400 meters 1300 feet In a closed loop subnet the m...

Страница 28: ...t be correct Instead measured and specified here is what is known as the Active Power in the amplifier providing useful real world values of power consumption and heat dissipation 2 Current draw figur...

Страница 29: ...world values of power consumption and heat dissipation 2 Current draw figures measured at 230 V 115 V figures are 230 V figures multiplied by two C 5 4X Level Load Rated power Line Current 2 Watt 1 T...

Страница 30: ...32 dBu 10 2 2 5 29 dBu dBu Vrms W1 W2 38 0 9 250 125 35 1 3 250 125 32 1 8 250 125 29 2 5 121 121 1 For C 10 4X C 20 8X in 4 ohms 2 For C 5 4X C 10 8X in 4 ohms 1 2 4 2 7 2 10 2 VPL Set to 63 V peak S...

Страница 31: ...rms 8 Arms 5 6 Arms 650 W 625 W 600 W 400 W 250 W 125 W 250 W 125 W 1200 W 1000 W 700 W 400 W 250 W 125 W 250 W 125 W 1700 W 1200 W 700 W 300 W 250 W 125 W 250 W 125 W 1200 W 600 W 300 W n r 4 125 W 6...

Страница 32: ...ndirect cost or losses however incurred Lab gruppen reserves the right to make changes or improvements in design or manufacturing without assuming any obligation to change or improve products previous...

Страница 33: ...L a b g r u p p e n AB S w e d e n i n t e r n a t i o n a L c o n t a c t i n f o L a b g r u p p e n c o m U S CONTACT i n f o u s t c e l e c t r o n i c c o m w w w l a b g r u p p e n c o m...

Отзывы: