C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual 

7.1  Introduction

The following sections provide comprehensive infor-

mation on amplifier connection, setup, operation, and 

performance. The detailed information included here 

is essential to realizing the full functionality of the C 

Series amplifiers.

7.2  Operation precautions

 Make sure that the Power switch and the Remote 

• 

switch on the amplifier front-panel are set to 

“off” before making any input, output or network 

connections, and also before manipulating the 

DIP-switches on the rear panel.

 This amplifier is equipped with a Universal Power 

• 

Supply that handles voltages from 100 V to 240 

V (+/- 10%) @ 50-60 Hz

7.3  Signal flow and headroom

7.3.1  Signal flow blocks

All C Series amplifiers have the same signal flow 

and feature set. The only difference is the amplifier’s 

maximum output current per channel. 

The input stage of all C Series amplifiers has a high 

sensitivity to provide ample system headroom. This 

in effect means that the input stage is almost impos-

sible to clip.

Overall amplifier input gain is adjusted using the input 

stage DIP-switches. Please note that the gain setting 

is global, affecting all channels. Following the input 

stage, the dedicated level control on each channel 

allows signal attenuation from 0 dB to  -infinity. 

The CPL (Current Peak Limiter) section dynamically 

limits the input signal based on three parameters: 

sensed current level, feedback from the output stage, 

and sensed voltage clip from the VPL (and output  

amplifier voltage clip if “Soft Clip” activated). This 

ensures that power output is maintained within the 

design limits of the amplifier.

The adjustable VPL (Voltage Peak Limiter) sets the  

maximum channel output voltage and therefore also 

the maximum channel output power. Four (4) different 

voltage stages are available using the DIP-switches 

on the rear panel. 

The sophisticated output section monitors faults 

and  generates  appropriate  warnings,  which  are  

displayed on the amplifier front-panel and transmitted 

through the NomadLink network. These alerts allow 

the operator to adjust system settings and thereby 

avoid problems. In the rare event that conditions are 

extraordinarily severe, the amplifier will shut down 

until the fault or problem setting has been rectified 

or adjusted. These sensing circuits are also employed 

to feed back voltage and current level information, 

via a side chain, to the limiters. Sensing circuits 

also transmit local amplifier module temperature 

and power supply temperature to the appropriate 

protection mechanisms. Read the Protection, Faults 

and Warnings section for further details.

7.3.2  headroom, sensitivity and VPL / Gain 

settings

The input amplifier and limiter system is designed to 

accommodate extremes of performance. Typically,

exceeding maximum input by much as +10 dB will

only result in a 1% increase in distortion. 

 If you use the level potentiometer in the 

signal chain to reduce the level by an amount 

greater than the headroom relative to input 

sensitivity, AND you drive the amplifier to 

clip level, you are in danger of clipping the input stage 

before  the  current  or  voltage  peak  limiters  are  

activated.

When bridging two channels, you must add 

6  dB  to  the  input  sensitivity  to  achieve 

maximum  output  voltage  due  to  the  

automatic  -6  dB  gain  compensation  

inserted by the amplifier.

7  OPERATION AND PERFORMANCE

Содержание C Series C 10 4X

Страница 1: ...Rev 1 0 2 Operation Manual C Series Dedicated Installation Amplifiers C 20 8X C 10 8X C 10 4X C 5 4X Item no OM CXS...

Страница 2: ...VPL 7 4 2 4 Protection and performance optimization 7 4 2 5 GPIO facilities and 35 Hz HPF 7 4 2 6 NomadLink Ethernet control and monitoring network 8 5 installation 9 5 1 Unpacking 9 5 2 Mounting 9 5...

Страница 3: ...20 7 6 2 Very High Frequency VHF protection 20 7 6 3 DC protection 21 7 6 4 High impedance warning open load 21 7 6 5 Low impedance protection short circuit 21 7 6 6 Temperature protection 21 7 6 7 Po...

Страница 4: ...ified by the manufacturer 11 The unit is intended to use in a 19 rack Follow the mounting instructions When a rack on wheels is used use caution when moving the loaded rack to avoid injury from tippin...

Страница 5: ...terference to radio or television reception which can be deter mined by turning the equipment on and off the user is encouraged to try to correct the interference by one or more of the following measu...

Страница 6: ...e or constant voltage 70 Vrms 100 V peak mode NomadLink an easy to use network for monitoring and control is implemented as a standard feature on all C Series amplifiers Although C Series features and...

Страница 7: ...ure protection ensures that the amplifier will not be damaged by exceeding thermal limits PAL Power Average Limiter limits the maximum average power consumption according to the power supply and mains...

Страница 8: ...d for easy system setup There is no need to create a star topology using many switches as with for example an Ethernet system Individual amplifier addresses do not need to be manually entered you will...

Страница 9: ...amplifier and that the rear of the amplifier has sufficient space to allow the exhaust to escape If the amplifier is rack mounted do not use covers or doors on the front or rear of the rack Should a h...

Страница 10: ...r terminal on the C Series amplifiers The signal ground is always floating via a resistor to chassis and therefore the grounding system is automatic In the interests of safety never disconnect the ear...

Страница 11: ...C Series C 20 8X C 10 8X C 10 4X and C 5 4X Operation Manual 11 11 This PAGE INTENTIONALLY LEFT BLANK...

Страница 12: ...ote switch is off it is not possible to switch amplifier power on or off using NomadLink network control 6 1 2 Front panel LED s The front panel LED area includes the following indicators per channel...

Страница 13: ...ODE HP 35H Z VPL CH F MODE HP 35H Z VPL CH G MODE HP 35H Z VPL CH H MODE HP 35H Z VPL CH B MODE HP 35H Z VPL CH C MODE HP 35H Z VPL CH D MODE HP 35H Z GAIN 38dB 35dB 32dB 29dB VPL 100V 70Vrms 63V 45V...

Страница 14: ...45 equipped cables US National Differences cl 16 3 requires that NomadLink network cables must be rated VW 1 The OUT port from the NLB 60E must be connected to the IN port of the first amplifier The O...

Страница 15: ...H E CH F CH G CH H BALANCED INPUTS BRIDGE A B BRIDGE E F VPL CH A MODE HP 35H VPL CH E MODE HP 35H VPL CH F MODE HP 35H VPL CH G MODE HP 35H VPL CH H MODE HP 35H VPL CH B MODE HP 35H VPL CH C MODE HP...

Страница 16: ...utput is maintained within the design limits of the amplifier The adjustable VPL Voltage Peak Limiter sets the maximum channel output voltage and therefore also the maximum channel output power Four 4...

Страница 17: ...ided at each channel output for connection of the speakers Make sure that the speaker cables are connected correctly and tightly and that accurate polarity is maintained to all speakers in the system...

Страница 18: ...ition indicating 10 dB Use your fingers or a screwdriver to adjust the potentiometers If the level control is used to attenuate to a lower level than the headroom relative to input sensitivity AND the...

Страница 19: ...the front panel Warnings also are shown in the DeviceControl software s GUI A steadily illuminated orange CPL LED indicates a short circuit situation or very low impedance The output will mute for 6 s...

Страница 20: ...ntact 1 kOhm 7 5 4 NomadLink disable switch The DIP switch labeled GPI NomadLink com pletely disables the amplifier s connectivity to the NomadLink network 7 6 Protection faults and warnings 7 6 1 Int...

Страница 21: ...by muting the output signal and bypassing the circuits Indication of this fault is a constant orange illumination of the Current Peak Limiter CPL LED on the front panel The protection will sequence a...

Страница 22: ...th a pre set delay between each amplifier s start up 7 7 Front panel monitoring and adjustments 7 7 1 Level indicators Five LED indicators per channel are contained on C X amplifier front panels Figur...

Страница 23: ...ance Warning and Fault indicators Power on off green indicates that mains power is switched on NomadLink blue indicates that the network is connected The NomadLink LED will light up even before the ma...

Страница 24: ...tive even when the amplifier has mains power disconnected or is not yet powered up This is due to the fact that the NomadLink network is solely powered via phantom power generated by the NLB 60E Shoul...

Страница 25: ...her or where groups of amplifiers within a single subnet with up to 60 units will be installed with a distance in between these general rules applying to Ethernet cabling limitations may be considered...

Страница 26: ...Windows PC which connects via Ethernet to the NLB 60E DeviceControl provides comprehensive monitoring of amplifier status as well as control of amplifier power on off and individual channel mute and...

Страница 27: ...imum cable length in between any two devices may not exceed 300 meters 980 feet In a non closed loop daisy chained subnet the maximum cable length is 400 meters 1300 feet In a closed loop subnet the m...

Страница 28: ...t be correct Instead measured and specified here is what is known as the Active Power in the amplifier providing useful real world values of power consumption and heat dissipation 2 Current draw figur...

Страница 29: ...world values of power consumption and heat dissipation 2 Current draw figures measured at 230 V 115 V figures are 230 V figures multiplied by two C 5 4X Level Load Rated power Line Current 2 Watt 1 T...

Страница 30: ...32 dBu 10 2 2 5 29 dBu dBu Vrms W1 W2 38 0 9 250 125 35 1 3 250 125 32 1 8 250 125 29 2 5 121 121 1 For C 10 4X C 20 8X in 4 ohms 2 For C 5 4X C 10 8X in 4 ohms 1 2 4 2 7 2 10 2 VPL Set to 63 V peak S...

Страница 31: ...rms 8 Arms 5 6 Arms 650 W 625 W 600 W 400 W 250 W 125 W 250 W 125 W 1200 W 1000 W 700 W 400 W 250 W 125 W 250 W 125 W 1700 W 1200 W 700 W 300 W 250 W 125 W 250 W 125 W 1200 W 600 W 300 W n r 4 125 W 6...

Страница 32: ...ndirect cost or losses however incurred Lab gruppen reserves the right to make changes or improvements in design or manufacturing without assuming any obligation to change or improve products previous...

Страница 33: ...L a b g r u p p e n AB S w e d e n i n t e r n a t i o n a L c o n t a c t i n f o L a b g r u p p e n c o m U S CONTACT i n f o u s t c e l e c t r o n i c c o m w w w l a b g r u p p e n c o m...

Отзывы: