Lab.gruppen C Series C 10 4X Скачать руководство пользователя страница 29

   

C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual  

29

APPENDIX  8

C 10:4X

Level

Load       

Rated power

Line Current *2)

Watt *1)

Thermal dissipation

120 VAC

230 VAC

In

Out

Dissipated

BTU/hr

kCal/hr

Standby w. remote Power Off via NomadLink

6

0

6

20

5

Power On, Idling

91

0

91

312

79

Amp

Watt

Pink noise 
(1/8)

70 V / Ch.

250

x4

2,7

1,4

274

125

149

509

128

16 Ω / Ch.

250

x4

2,5

1,3

252

125

127

432

109

32 Ω / Bridged

500

x2

100 V / Ch.

250

x4

2,0

1,0

225

125

100

341

86

500

x2

8 Ω / Ch.

500

x2

2,1

1,1

217

125

92

314

79

16 Ω / Bridged

4 Ω / Ch.

250

x4

2,3

1,2

230

125

105

359

90

8 Ω / Bridged

500

x2

2 Ω / Ch.

125

x4

1,3

0,7

136

63

73

249

63

4 Ω / Bridged

250

x2

Pink noise 
(1/4)

70 V / Ch.

250

x4

4,9

2,6

526

250

276

942

237

16 Ω / Ch.

250

x4

4,3

2,2

458

250

208

710

179

32 Ω / Bridged

500

x2

100 V / Ch.

500

x2

3,3

1,7

384

250

134

456

115

8 Ω / Ch.

250

x4

3,5

1,8

364

250

114

388

98

16 Ω / Bridged

500

x2

4 Ω / Ch.

250

x4

3,6

1,9

373

250

123

421

106

8 Ω / Bridged

500

x2

2 Ω / Ch.

125

x4

2,2

1,1

219

125

94

321

81

4 Ω / Bridged

250

x2

*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and 

specified here is what is known as the “Active Power” in the amplifier providing useful, real-world values of power consumption and heat dissipation.

*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.    

C 5:4X

Level

Load       

Rated power

Line Current *2)

Watt *1)

Thermal dissipation

120 VAC

230 VAC

In

Out

Dissipated

BTU/hr

kCal/hr

Standby w. remote Power Off via NomadLink

6

0

6

20

5

Power On, Idling

91

0

91

312

79

Amp

Watt

Pink noise 
(1/8)

70 V / Ch.

125

x4

1,7

0,9

176

63

114

387

98

16 Ω / Ch.

125

x4

1,5

0,8

156

63

94

319

80

32 Ω / Bridged

250

x2

100 V / Ch.

250

x2

1,4

0,7

152

63

89

305

77

8 Ω / Ch.

125

x4

1,3

0,7

134

63

72

244

62

16 Ω / Bridged

250

x2

4 Ω / Ch.

125

x4

1,3

0,7

131

63

68

233

59

8 Ω / Bridged

250

x2

2 Ω / Ch.

63

x4

0,9

0,5

94

32

62

213

54

4 Ω / Bridged

126

x2

Pink noise 
(1/4)

70 V / Ch.

125

x4

3,0

1,6

330

125

205

700

176

16 Ω / Ch.

125

x4

2,4

1,3

265

125

140

476

120

32 Ω / Bridged

250

x2

100 V / Ch.

250

x2

2,3

1,2

252

125

127

433

109

8 Ω / Ch.

125

x4

2,0

1,1

222

125

97

331

83

16 Ω / Bridged

250

x2

4 Ω / Ch.

125

x4

2,1

1,1

228

125

103

350

88

8 Ω / Bridged

250

x2

2 Ω / Ch.

63

x4

1,3

0,7

139

63

76

260

65

4 Ω / Bridged

126

x2

*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and 

specified here is what is known as the “Active Power” in the amplifier providing useful, real-world values of power consumption and heat dissipation.

*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.    

Содержание C Series C 10 4X

Страница 1: ...Rev 1 0 2 Operation Manual C Series Dedicated Installation Amplifiers C 20 8X C 10 8X C 10 4X C 5 4X Item no OM CXS...

Страница 2: ...VPL 7 4 2 4 Protection and performance optimization 7 4 2 5 GPIO facilities and 35 Hz HPF 7 4 2 6 NomadLink Ethernet control and monitoring network 8 5 installation 9 5 1 Unpacking 9 5 2 Mounting 9 5...

Страница 3: ...20 7 6 2 Very High Frequency VHF protection 20 7 6 3 DC protection 21 7 6 4 High impedance warning open load 21 7 6 5 Low impedance protection short circuit 21 7 6 6 Temperature protection 21 7 6 7 Po...

Страница 4: ...ified by the manufacturer 11 The unit is intended to use in a 19 rack Follow the mounting instructions When a rack on wheels is used use caution when moving the loaded rack to avoid injury from tippin...

Страница 5: ...terference to radio or television reception which can be deter mined by turning the equipment on and off the user is encouraged to try to correct the interference by one or more of the following measu...

Страница 6: ...e or constant voltage 70 Vrms 100 V peak mode NomadLink an easy to use network for monitoring and control is implemented as a standard feature on all C Series amplifiers Although C Series features and...

Страница 7: ...ure protection ensures that the amplifier will not be damaged by exceeding thermal limits PAL Power Average Limiter limits the maximum average power consumption according to the power supply and mains...

Страница 8: ...d for easy system setup There is no need to create a star topology using many switches as with for example an Ethernet system Individual amplifier addresses do not need to be manually entered you will...

Страница 9: ...amplifier and that the rear of the amplifier has sufficient space to allow the exhaust to escape If the amplifier is rack mounted do not use covers or doors on the front or rear of the rack Should a h...

Страница 10: ...r terminal on the C Series amplifiers The signal ground is always floating via a resistor to chassis and therefore the grounding system is automatic In the interests of safety never disconnect the ear...

Страница 11: ...C Series C 20 8X C 10 8X C 10 4X and C 5 4X Operation Manual 11 11 This PAGE INTENTIONALLY LEFT BLANK...

Страница 12: ...ote switch is off it is not possible to switch amplifier power on or off using NomadLink network control 6 1 2 Front panel LED s The front panel LED area includes the following indicators per channel...

Страница 13: ...ODE HP 35H Z VPL CH F MODE HP 35H Z VPL CH G MODE HP 35H Z VPL CH H MODE HP 35H Z VPL CH B MODE HP 35H Z VPL CH C MODE HP 35H Z VPL CH D MODE HP 35H Z GAIN 38dB 35dB 32dB 29dB VPL 100V 70Vrms 63V 45V...

Страница 14: ...45 equipped cables US National Differences cl 16 3 requires that NomadLink network cables must be rated VW 1 The OUT port from the NLB 60E must be connected to the IN port of the first amplifier The O...

Страница 15: ...H E CH F CH G CH H BALANCED INPUTS BRIDGE A B BRIDGE E F VPL CH A MODE HP 35H VPL CH E MODE HP 35H VPL CH F MODE HP 35H VPL CH G MODE HP 35H VPL CH H MODE HP 35H VPL CH B MODE HP 35H VPL CH C MODE HP...

Страница 16: ...utput is maintained within the design limits of the amplifier The adjustable VPL Voltage Peak Limiter sets the maximum channel output voltage and therefore also the maximum channel output power Four 4...

Страница 17: ...ided at each channel output for connection of the speakers Make sure that the speaker cables are connected correctly and tightly and that accurate polarity is maintained to all speakers in the system...

Страница 18: ...ition indicating 10 dB Use your fingers or a screwdriver to adjust the potentiometers If the level control is used to attenuate to a lower level than the headroom relative to input sensitivity AND the...

Страница 19: ...the front panel Warnings also are shown in the DeviceControl software s GUI A steadily illuminated orange CPL LED indicates a short circuit situation or very low impedance The output will mute for 6 s...

Страница 20: ...ntact 1 kOhm 7 5 4 NomadLink disable switch The DIP switch labeled GPI NomadLink com pletely disables the amplifier s connectivity to the NomadLink network 7 6 Protection faults and warnings 7 6 1 Int...

Страница 21: ...by muting the output signal and bypassing the circuits Indication of this fault is a constant orange illumination of the Current Peak Limiter CPL LED on the front panel The protection will sequence a...

Страница 22: ...th a pre set delay between each amplifier s start up 7 7 Front panel monitoring and adjustments 7 7 1 Level indicators Five LED indicators per channel are contained on C X amplifier front panels Figur...

Страница 23: ...ance Warning and Fault indicators Power on off green indicates that mains power is switched on NomadLink blue indicates that the network is connected The NomadLink LED will light up even before the ma...

Страница 24: ...tive even when the amplifier has mains power disconnected or is not yet powered up This is due to the fact that the NomadLink network is solely powered via phantom power generated by the NLB 60E Shoul...

Страница 25: ...her or where groups of amplifiers within a single subnet with up to 60 units will be installed with a distance in between these general rules applying to Ethernet cabling limitations may be considered...

Страница 26: ...Windows PC which connects via Ethernet to the NLB 60E DeviceControl provides comprehensive monitoring of amplifier status as well as control of amplifier power on off and individual channel mute and...

Страница 27: ...imum cable length in between any two devices may not exceed 300 meters 980 feet In a non closed loop daisy chained subnet the maximum cable length is 400 meters 1300 feet In a closed loop subnet the m...

Страница 28: ...t be correct Instead measured and specified here is what is known as the Active Power in the amplifier providing useful real world values of power consumption and heat dissipation 2 Current draw figur...

Страница 29: ...world values of power consumption and heat dissipation 2 Current draw figures measured at 230 V 115 V figures are 230 V figures multiplied by two C 5 4X Level Load Rated power Line Current 2 Watt 1 T...

Страница 30: ...32 dBu 10 2 2 5 29 dBu dBu Vrms W1 W2 38 0 9 250 125 35 1 3 250 125 32 1 8 250 125 29 2 5 121 121 1 For C 10 4X C 20 8X in 4 ohms 2 For C 5 4X C 10 8X in 4 ohms 1 2 4 2 7 2 10 2 VPL Set to 63 V peak S...

Страница 31: ...rms 8 Arms 5 6 Arms 650 W 625 W 600 W 400 W 250 W 125 W 250 W 125 W 1200 W 1000 W 700 W 400 W 250 W 125 W 250 W 125 W 1700 W 1200 W 700 W 300 W 250 W 125 W 250 W 125 W 1200 W 600 W 300 W n r 4 125 W 6...

Страница 32: ...ndirect cost or losses however incurred Lab gruppen reserves the right to make changes or improvements in design or manufacturing without assuming any obligation to change or improve products previous...

Страница 33: ...L a b g r u p p e n AB S w e d e n i n t e r n a t i o n a L c o n t a c t i n f o L a b g r u p p e n c o m U S CONTACT i n f o u s t c e l e c t r o n i c c o m w w w l a b g r u p p e n c o m...

Отзывы: