6. Appendix
32
C Series C 88:4, C 68:4, C 48:4, C 28:4 and C 16:4 Operation Manual rev 2.2.3
C 16:4
Level
Load
Rated power
Line Current *2)
Watt *1)
Thermal Dissipation
115 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby with remote power off via NomadLink
0
0
0
0
0
Powered on, idling.
129
0
129
440
111
Amp (I)
Watt
Pink noise (1/8
rated power)
8 Ω / Ch.
400 x 4
8.6
4.3
526
200
326
1112
280
16 Ω / Bridged
800 x 2
4 Ω / Ch.
300 x 4
8.2
4.1
485
150
335
1143
288
8 Ω / Bridged
600 x 2
2 Ω / Ch.
n.r.
*4)
4 Ω / Bridged
n.r.
*4)
100V / Ch.
400 x 4
7.6
3.8
463
200
263
897
226
200V / Bridged
800 x 2
Pink noise
(max power)
*3)
8 Ω / Ch.
400 x 4
16.2
8.1
1046
533
513
1749
441
16 Ω / Bridged
800 x 2
4 Ω / Ch.
300 x 4
15.2
7.6
953
400
553
1887
475
8 Ω / Bridged
600 x 2
2 Ω / Ch.
n.r.
*4)
4 Ω / Bridged
n.r.
*4)
100 V / Ch.
400 x 4
14.4
7.2
944
533
411
1401
353
200 V / Bridged
800 x 2
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
15 A / 5-15P
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
specifi ed here is what is known as the “Active Power” in the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation.
Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped
even if operation is
momentarily
in excess of max. ratings.
*4) Regarding n.r. (not recommended) notes: The amplifi er will be fully operational in bridge-mode into 2 or 4 ohms, but due to physical
constraints in the construction, the max. output power will not be signifi canty higher than running individual channels and therefore this mode of
operation is not recommended.
Table 8.4e: C 16:4 Current Draw and Thermal Dissipation specifications