31
6. Appendix
C Series C 88:4, C 68:4, C 48:4, C 28:4 and C 16:4 Operation Manual rev 2.2.3
C 28:4
Level
Load
Rated power
Line Current *2)
Watt *1)
Thermal Dissipation
115 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby with remote power off via NomadLink
0
0
0
0
0
Powered on, idling.
123
0
123
420
106
Amp (I)
Watt
Pink noise (1/8
rated power)
8 Ω / Ch.
700 x 4
11.6
5.8
727
350
377
1286
324
16 Ω / Bridged
1400 x 2
4 Ω / Ch.
700 x 4
13.0
6.5
775
350
425
1450
365
8 Ω / Bridged
1400 x 2
2 Ω / Ch.
300 x 4
9.4
4.7
529
150
379
1293
326
4 Ω / Bridged
600 x 2
100 V / Ch.
700 x 4
10.4
5.2
663
350
313
1068
269
200 V / Bridged
1400 x 2
Pink noise
(max power)
*3)
8 Ω / Ch.
700 x 4
24.0
12.0
1589
933
656
2237
564
16 Ω / Bridged
1400 x 2
4 Ω / Ch.
700 x 4
20.8
10.4
1359
700
659
2249
567
8 Ω / Bridged
1400 x 2
4 Ω / Ch.
300 x 4
14.0
7.0
843
300
543
1853
467
8 Ω / Bridged
600 x 2
100 V / Ch.
700 x 4
21.4
10.7
1458
933
525
1790
451
200 V / Bridged
1400 x 2
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
20 A / 5-20P
*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and
specifi ed here is what is known as the “Active Power” in the amplifi er providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.
*3) Figures measured at maximum sustainable power without tripping the mains fuse. Listed separately for 30 A/115 V and 16 A/230 V operation.
Note that the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped
even if operation is
momentarily
in excess of max. ratings.
Table 8.4d: C 28:4 Current Draw and Thermal Dissipation specifications