Page 48
LAARS Heating Systems
8.7.4 DHW - Domestic Hot Water
Configuration
DHW - Domestic Hot Water is used to configure the DHW
temperature parameters for water heaters (NTV) and for
indirect water heaters that are used with boiler (NTH) systems.
8.7.5 Warm Weather Shutdown
Configuration
From this sub-menu you will be able to enable/disable the
Warm Weather Shutdown feature and adjust the set point.
8.7.6 Demand Priority Configuration
From the Demand Priority Configuration, the installer can
adjust the priority of the different demand types.
-Central Heat
-Domestic Hot Water
-Lead Lag
The control uses arrows as indicators to point to the loop with
higher priority.
8.7.7 Modulation Configuration
From this sub-menu the installer has the ability to adjust
the range of modulation for the CH, and DHW demands.
NeoTherm is designed with a 5:1 turn down ratio. Any
change to the minimum and maximum modulation rates
will affect the overall ratio of the boiler. The installer level
password will allow changes to these parameters. Consult
the factory if an adjustment is needed to any of these
parameters.
8.7.8 Pump Connections
The controller in the NeoTherm energizes the pump contacts
when it receives a call for heat. Once the call for heat is
satisfied, the pump will remain on for the defined pump
overrun time.\
The Boiler Pump terminals (TB5 - max 7.4 FLA) are fed by
120V (violet wire) internally from the main power feed. The
System and DHW contacts are dry contacts. Appropriate
voltage must be supplied to the System and DHW pumps for
proper operation.
Содержание NTH
Страница 4: ...LAARS Heating Systems...
Страница 13: ...Page 9 NEOTHERM Boilers and Water Heaters 38 1 2 98 8 3 4 22 7 1 2 19 64...
Страница 30: ...Page 26 LAARS Heating Systems Figure 21 Hydronic Piping Single Boiler Zoning with Circulators...
Страница 32: ...Page 28 LAARS Heating Systems Figure 23 Hydronic Piping Multiple Boilers Zoning with Circulators...
Страница 86: ...Page 82 LAARS Heating Systems Parts Illustration 1 Jacket Components...
Страница 88: ...Page 84 LAARS Heating Systems Parts Illustration 4 Internal Components Sizes 750 850...
Страница 90: ...Page 86 LAARS Heating Systems Parts Illustration 6 Gas Train Components Sizes 600 850...
Страница 91: ...Page 87 NEOTHERM Boilers and Water Heaters Parts Illustration 7 Heat Exchanger Components 68A Sizes 285...
Страница 92: ...Page 88 LAARS Heating Systems Parts Illustration 8 Electrical Components Front Battery CR2032 Touchscreen Back...
Страница 93: ...Page 89 NEOTHERM Boilers and Water Heaters Notes...
Страница 94: ...Page 90 LAARS Heating Systems Notes...
Страница 95: ...Page 91 NEOTHERM Boilers and Water Heaters Notes...