Page 3
5
· Provides best energy savings option
· Designed to meet California Title 24 requirements.
· Recirculation will only operate when the push button switch is pressed. Hot water will not be available
immediately.
· Built-in timer function is disabled
· Will start circulation pump on-demand to purge cold water from the water lines and replace with hot water.
· Pump will stop operating once hot water has successfully reached 102
°
F at the installed temperature sensor.
· Do not repeatedly press on-demand button. On-demand function will not operate if the water in the line is
already warm.
Recirculation Mode
[ On Demand(tt24) Mode]
Dedicated
Return Line
Accessory
Setting
Maximum Loop Length
Controlled by
11 : RC
1/2"
3/4"
YES
Suface
Temperature
Sensor
tt24
200' (60m)
500' (150m)
Push Button Switch
Temp.
Sensor