ALARMS DESCRIPTION
4.1
LACK OF WATER INSIDE THE TANK
The lack of water inside the tank (4) is shown by the turning on, on the control panel (9), of the red light (13);
fill in the tank with at least 1 litre of drinkable and cold water (the tank contains maximum 3 litres).
4.2
DAMAGED WATER DOSING SYSTEM FOR COFFEE
(only in the automatic version)
This alarm indicates that there is an anomaly on the water dosing system to brew coffee. This could be either
due to the wrong operation of the flowmeter or to a too fine coffee grinding.
The alarm is signalled by the turning on of lights 14-15-16 if you are using a 1 coffee dose and the control
lights 17-18-19 if you are using a 2 coffee dose.
The machine keeps delivering coffee without stopping at the programmed dose; in order to stop it press the
one coffee (24) or two coffee (25) button.
If this alarm appears, call the authorised technical assistance centre.
4.3
DAMAGED TEMPERATURE MEASUREMENT SYSTEM
This is a blocking alarm and it appears when the control lights 20-21 turn on fixed.
This alarm shows when temperature rises over 145
°
C (temperature probe in short circuit) or is inferior to
60
°
C (temperature probe disconnected).
When you first turn on the machine, if after 5 minutes the temperature doesn’t rise above 60
°
C this alarm
appears.
When this alarm appears, disconnect the machine from the electric system and call the authorised technical
assistance centre.
4.4
DAMAGED TRIAK
This is a blocking alarm and it appears with the flashing of control lights 20-21. This alarm appears when
temperature rises over 140
°
C (triak always in conduction), if this alarm appears disconnect the machine from
the electric system and call the authorised technical assistance centre.