![La Spaziale S 3 Скачать руководство пользователя страница 11](http://html2.mh-extra.com/html/la-spaziale/s-3/s-3_manual-for-use-and-maintenance_3129143011.webp)
MANUAL FOR USE AND MAINTENANCE
LSC 001 -UK- REV. 06
11
TEMPORARY TEMPERATURE INCREASE FUNCTION
(Range S5)
When the appliance is used in conditions where its temperature could be lowered quite notably, holding
down the button
(37) for about 5 seconds will increase the boiler temperature by 2 °C. In this
condition, the programmed SET temperature will continue to flash on the control panel (13) and at the
same time, the temperature symbol, 2° C above the programmed SET temperature will begin to flash
(e.g., if the SET temperature is 120°C, this will begin to flash and continue to do so, while 122°C will
begin to flash).
The new SET will follow the progress of the temperature, flashing when the appliance is heating up
and fixed when the set temperature has been reached.
To return to the initial status, press the button
(38) for about 5 seconds.
AUTOMATIC SYSTEM WITH MILK EMULSION WITH ADJUSTABLE TEMPERATURE - M.A.T.
(Range S5) (optional)
Appliances fitted with this system can foam milk completely automatically.
a) Insert the steam wand complete with temperature sensor (45) into the pitcher of milk.
b) Press the automatic steam dispensing button for milk (44).
c) The steam will stop automatically as soon as the temperature set during installation has been
reached.
d) When the milk has been foamed, remove the pitcher and use a damp sponge to clean all milk residues
from the steam wand with temperature sensor (45).
NOTE. Do not press the automatic steam delivery button for milk foaming (44) before inserting the
steam wand with temperature sensor (45) into the pitcher, in order to prevent possible burns.
To adjust milk foaming, use the regulator (46) located on the back of the front panel, next to the steam
wand with temperature sensor (45).
Turn the adjustment screw anticlockwise to increase foaming.
Turn the adjustment screw clockwise to reduce foaming.
WARNING!
When adjusting the milk foaming level, take care not to touch the steam wand with temperature
sensor (45) or wear protective gloves, to prevent possible burns.