24
EOLO - COMFORT 80
EN
If after some months the flame appears weak and/or orange colored or the glass tends to
blackens and the burning pot to become encrusted, clean the stove, clean the fume pipe
and the chimney flue.
12.7
POWER FAILURE
•
After a black-out off less than 5 seconds, the stove returns to the set power.
•
After a black-out of more than 5 seconds, the stove enters the stage “COOLING WAIT". At the end of cooling
stage, it starts automatically up with the different stages (see
12.8
TEMPERATURE SETTING
•
To modify the room temperature, it is sufficient to press P1 and P2 keys according to the desired temperature
when the display shows "SET TEMP ROOM".
•
To display the set temperature, press P1 key.
12.9
FUME TEMPERATURE
To check fume temperature at the exhaust outlet, it is sufficient to keep pressed P2 key.
12.10
SWITCHING OFF
To switch off the stove keep pressed P4 key: the display shows “FINAL CLEANING”. After 10 minutes also the fume
extractor switches off (this occurs always, whether the stove is hot or cold). Then the display shows "OFF".
If the pellets are of bad quality (if contain sizing agents, oils, varnishes, plastic remains or if
it is mealy), during the running deposits will form along pellets drop pipe. When the stove is
switched off, these remains could form little hot coals that rising along the pipe could reach
the pellets on the hopper burning them and creating a thick and harmful smoke inside tho
room. Please always keep the hopper closed with its own lid. If the pipe is sooty, please
clean it (see
12.11
CLOCK SETTING
•
Press P3 and then P5 key till the display shows the menu (02) SET CLOCK.
•
Press P3 key (DAY) and with P1 and P2 keys select the day of the week (Monday, Tuesday, Wednesday,
Thursday, Friday, Saturday, Sunday).
•
Press P3 key again (TIME) and with P1 and P2 keys select the time.
•
Press P3 key again (MINUTES) and with P1 and P2 key select the minutes.
•
Press P3 key again (DAY) and with P1 and P2 key select the day of the month (1, 2, 3 …29, 30, 31).
•
Press P3 key again (MONTH) and with P1 and P2 keys select the month.
•
Press P3 key again (YEAR) and with P1 and P2 keys select the year.
•
To exit press twice P4.
12.12
DAILY PROGRAMMING
It is useful to enable, disable and set daily chronothermostat functions. Press P3 key and then P5 key till the display
shows (03) "SET CHRONO". Press P3 key and with P5 and P6 key select "PROGRAM DAY". Press P3, the display
shows "CHRONO DAY". With P1 and P2 keys put in "OFF" or "ON".
It is possible to set two running period limited by the selected times.
After "CHRONO DAY”:
•
Press P5: the display shows "START 1", with P1 and P2 keys enter the ignition time or put in "OFF".
•
Press P5: The display shows "STOP 1", with P1 and P2 keys enter the switching off time or put in "OFF".
•
Press P5: the display shows "START 2", with P1 and P2 keys enter the ignition time or put in "OFF".
•
Press P5: the display shows "STOP 2", with P1 and P2 keys enter the switching off time or put in "OFF".
•
To exit press three times P4 key.
12.13
WEEK-END PROGRAMMING
It is useful to enable, disable and set the chronothermostat functions during the weekend. Press P3 key and then
P5 key till it appears (03) “SET CHRONO” menu. Press P3 key and with P5 and P6 keys select “PROGRAM WEEK-
END”. Press P3 till the display shows “CHRONO WEEK-END” and, with P1 and P2 keys put in "OFF" or "ON".
It is possible to set two running periods limited by the selected times which activate only saturday and sunday.
After “CHRONO WEEK-END”:
•
Press P5: the display shows “START 1 WEEK-END” and with P1 and P2 keys enter the ignition time or put in "OFF".
•
Press P5: the display shows “STOP 1 WEEK-END” and with P1 and P2 enter the switching off time or put in "OFF".
•
Press P5: the display shows “START 2 WEEK-END” and with P1 and P2 keys enter the ignition time or put in "OFF".
•
Press P5: the display shows “STOP 2 WEEK-END” and with P1 and P2 enter the switching off time or put in "OFF".
•
To exit press three times P4 key.