EN
10
the hopper has been cleaned, it must be
positioned correctly on the appliance.
If the hopper is not correctly positioned
grinding cannot begin.
12.2.2. Cleaning Grinding System
To access the grinding system, remove
components in this order:
- Close the hopper;
- Grind the coffee residue left in the
grinding chamber;
- Unscrew the adjuster knob in the direc-
tion of the larger numbers and continue
unscrewing it until it is completely re-
moved.
With a small brush, clean the burrs.
Vacuum the coffee fragments and ground
residues from the grinding chamber, taking
care to clean all components thoroughly.
- Replace the adjuster knob as shown in
the following image
Periodic cleaning is recommended to
ensure correct operation of the appliance.
12.3. Replacement of the Grinding Blades
The state of the grinding blades must be
checked periodically. Keeping the grinding
burrs in an excellent state ensures high
quality grinding, resulting in greater
productivity and limited overheating.
After removing the adjuster knob as
explained in the previous section, replace
the internal burr.
To replace the external grinder, lift the
tab shown in the image and insert a
screwdriver from above. Using the tool
provided, remove the external grinder as
shown in the following image.
Proceed with the replacement with a new
pair of burrs.
WARNING
The following maintenance
and inspection tasks should
be carried out by a qualified
technician.
Remove
Adjuster Knob
Remove
Adjuster Knob
Tab to lift