manualshive.com logo in svg
background image

(P/N) 737.098 Rev A • 04/09 

 © copyright 2009 

Kaba Mas LLC

 

Page 2 of 4

OPEN LOCK

1. Enter valid combination.
2. For Dual User access, enter the second valid combination.
3. Open the container within 4 seconds.

TIME DELAY DISPLAY

The time display will operate during a time delay period and opening window. The time 
display format is 

mm:ss

 (minutes and seconds.) The default device operation is set to 

count down for the time delay period and count up for the opening window. To change 
the counting direction, see section on 

CHANGE COUNTING DIRECTION.

CHANGE COUNTING DIRECTION

Two jumper switches are available on the control card of 
the entry device to control the counting direction of the LCD 
display for time delay and open window. 

No jumper = Count up

Jumper on = Count down

The device is shipped with a jumper on the switch for time 
delay and no jumper on the switch for the opening window 
as shown in the photo (Figure 1); therefore, the default status 
of the device is that time delay counts down and the opening 
window counts up.

An additional jumper is included in the hardware pack with 
the entry device. You can change the counting direction(s) 
by adding another jumper, by switching the position of the 
original jumper, or by removing the original jumper. 

Note: 

To remove the back cover, use a medium-sized Phillips head screwdriver. If you 

change the jumper settings, they will not be recognized until the next power up of the 
entry device. Therefore, you must remove the battery if installed and drain the remaining 
power by holding and pressing a key or by pressing multiple keys continuously.

OPEN LOCK WITH TIME DELAY

1. Enter valid combination. The time delay display will be activated. (See TIME 
 DELAY 

DISPLAY.)

2. Once the Time Delay has expired and the lock has entered the “open window”,  enter 
  valid combination again. 

3. For Dual User access, enter the second valid combination.

4. Open the container within 4 seconds.

TIME DELAY OVERRIDE

This feature enables a User to override Time Delay. The feature must be programmed 
when the lock is set up. Refer to the Manager instructions for more detail.

If operating in Dual Combo Mode, the manager or a user combination must fi rst be 
entered, then the override combination.

Jumper On
- Delay 
switch = 
Count Down

No Jumper
- Open
switch = 
Count Up