1.

 

Remove the battery cover.  To do this, insert a solid object in the space provided at the lower-central position of the 
battery cover, then push up and pull out on the battery cover. 

2.

 

Observe the correct polarity, and install 3 AA batteries. 

3.

 

Replace the battery cover. 

 

Note:

  Immediately after the batteries have been installed, the LCD (Liquid Crystal Display) will flash.  Within 15 

seconds the indoor temperature, indoor relative humidity, and the weather icons (sun and clouds) will be displayed.  
If not, remove batteries for 10 seconds and reinstall. If the outdoor temperature is not displayed within four minutes, 
remove batteries from both units, wait 30 seconds, and reinstall making sure to install batteries into the remote 
temperature sensor first. The time will show -:-- and start searching for the WWVB signal. If it successfully receives 
the time signal (usually at night), it will display the correct time (default time-zone is Eastern). You will need to 
adjust the time zone to match your local time. 

 

PROGRAM MODE 

 

Programming Note:

 If 30 seconds are allowed to pass, or the 

WIND/SNZ

 button is pressed during the programming mode, the 

unit will confirm/set the last information entered—the display will stop flashing and return to normal time-date readings. If you 
don’t leave the program mode during the programming of sections IV through XI, you can advance to step 4 of the next program 
setting.  If you do leave the program setting (or want to program a specific setting) follow each instructional step to program that 
setting. 

 

I.

 

PROGRAMMING SEQUENCE AND DEFAULT SETTINGS

 

 

The programming sequence and default (factory) settings are as follows: 

 

LCD Contrast 

Time Zone 

-5 (Eastern) 

Daylight Saving Time 

ON 

Radio-controlled time reception 

ON 

12/24-hour time 

12 

Time – Hour 

12 

Time – Minute 

:00 

Year 2003 

Month 1 

Day 1 

Snooze 10 

minutes 

Temperature Format 

°

Forecast Sensitivity 

 

II.

 

FUNCTION KEYS

 

 

The function keys are located on the front of the unit directly below the LCD (Liquid Crystal Display). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание WS-9035TWC

Страница 1: ...WS 9035TWC Wireless 433 MHz Radio controlled Weather Station Instruction Manual...

Страница 2: ...etting the Time 8 Setting the Year Day and Month 9 Setting the Snooze 9 Setting the Temperature Format 9 Setting the Forecast Sensitivity 10 Features Weather Forecast Icons and Tendency Arrows 11 Indo...

Страница 3: ...continuously throughout the United States at 60 kHz The signal can be received up to 2 000 miles away through the internal antenna in the Weather Station However due to the nature of the Earth s Iono...

Страница 4: ...ugh will reduce distance An outdoor wall or window can have up to 30 feet of resistance and an interior wall can have up to 20 feet of resistance Your distance plus resistance should not exceed 300 ft...

Страница 5: ...correct time default time zone is Eastern You will need to adjust the time zone to match your local time PROGRAM MODE Programming Note If 30 seconds are allowed to pass or the WIND SNZ button is press...

Страница 6: ...Atlantic 4 EST Eastern 5 CST Central 6 MST Mountain 7 PST Pacific 8 ALA Alaska 9 HAW Hawaii 10 6 Press and release the SET button to confirm and advance to the Daylight Saving Time setting V DAYLIGHT...

Страница 7: ...tion is at night between midnight and 6 00 am when there is less atmospheric interference To keep your time as accurate as possible the indoor weather station conducts a WWVB search every night betwee...

Страница 8: ...t the duration of the snooze Note The snooze can be set for 0 to 30 minutes in 5 minute increments If 0 minutes is selected pressing the WIND SNZ button will deactivate the alarm and it will not come...

Страница 9: ...a necessity to disregard all weather forecasting for 12 24 hours after the unit has been set up reset or moved from one altitude to another i e from one floor of a building to another floor In areas w...

Страница 10: ...ator is located at the bottom left of the INDOOR LCD The indicator will display a happy face icon when the temperature is between 68 F and 79 F 20 C and 25 9 C and the humidity is between 45 and 64 A...

Страница 11: ...either MAX or MIN 2 Press and hold the SET button for 5 seconds 3 The record is now reset and will show the current time in the TIME LCD and current outdoor temperature and humidity in the OUTDOOR LC...

Страница 12: ...s and hold the WIND SNZ button for 3 seconds 2 The WIND SPEED LCD will now show the maximum wind 3 Press and release the WIND SNZ button again 4 The WIND SPEED LCD will now show the maximum wind gust...

Страница 13: ...3 18 mph 20 28 kph 11 16 knots Moderate Breeze Small branches move raises dust leaves and paper Small waves develop becoming longer whitecaps 5 19 24 mph 29 38 kph 17 21 knots Fresh Breeze Small trees...

Страница 14: ...ss and hold the ALM button for 5 seconds 2 The alarm time will begin to flash in the DATE LCD 3 Press and release the IN HR button to adjust the hour Note When in the 12 hour mode and setting an alarm...

Страница 15: ...RE HUMIDITY SENSOR The remote temperature humidity sensor can be mounted in several ways With the use of screws Using adhesive tape Using nylon straps A MOUNTING WITH SCREWS 1 Remove the mounting brac...

Страница 16: ...y 3 16 of an inch 5mm extended from the wall 2 Place the indoor weather station onto the screw using the hanging hole on the backside 3 Gently pull the indoor weather station down to lock the screw in...

Страница 17: ...absorb and store heat from external sources i e handling of the case or radiant heat Also the much greater range of the remote temperature humidity sensor requires a different calibration curve than...

Страница 18: ...ature checking interval Every 15 seconds Indoor humidity checking interval Every 20 seconds Outdoor temperature checking interval remote temperature humidity sensor Every 128 seconds Outdoor humidity...

Страница 19: ...erefore the above exclusion of limitation may not apply to you For warranty work technical support or information contact La Crosse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 F...

Отзывы: