background image

 

4

QUICK SET-UP GUIDE 

 

Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries. 

 
1.

 

Have the indoor weather station, remote temperature/humidity sensor and wind speed sensor 3 to 5 feet apart. 

2.

 

Insert the telephone plug (RJ-11) from the wind speed sensor into the receptacle on the remote temperature/humidity 
sensor. 

3.

 

Batteries should be out of both the indoor weather station and remote temperature/humidity sensor units for 10 minutes. 

4.

 

Place the batteries into the 

remote temperature/humidity sensor

 first then into the 

indoor weather station

5.

 

DO NOT PRESS ANY BUTTONS FOR 15 MINUTES. 

 
In this time the indoor weather station and remote temperature/humidity sensor will start to talk to each other and the display will 
show the indoor temperature/humidity, outdoor temperature/humidity and wind speed.  If the indoor weather station does not display 
all information after the 15 minutes please retry the set up as stated above.  After all information has been displayed for 15 minutes 
you can place your sensors outdoors and set your time. 
 

Important Notes on Set-up and Operation 

 

 

The remote temperature/humidity sensor is both the source of power for both outdoor sensors and source of transmission for all 
remote sensor data.   

 

 

The remote temperature/humidity sensor should be placed in a dry, shaded area.   

 

 

Fog and mist will not harm your remote temperature/humidity sensor but direct rain must be avoided.   

 

 

Direct rainfall will not harm the wind speed sensor. 

 

 

The remote temperature/humidity sensor has a range of 300 feet.  Any walls that the signal will have to pass through will reduce 
distance.  An outdoor wall or window can have up to 30 feet of resistance and an interior wall can have up to 20 feet of 
resistance.  Your distance plus resistance should not exceed 300 ft. in a straight line. 

 

 

The remote temperature/humidity sensor transmits a signal every minute.  After the batteries have been installed, the indoor 
weather station will search for the signal for a duration of 15 minutes.  If there is no temperature or humidity reading in the 
OUTDOOR LCD or wind speed in the WIND SPEED LCD after 15 minutes, make sure the units are within range of each other, 
or repeat the battery installation procedure. 

 

 

If a button is pressed before the indoor weather station receives the signal from the remote temperature/humidity sensor, you will 
need to follow the battery installation procedure again. 

 
To complete the set up of your new wireless weather station after the 15 minutes have passed please follow the steps that follow in the 
Detailed Set-Up Guide. 
 

DETAILED SET-UP GUIDE 

 

BATTERY INSTALLATION 

 
The first step to powering up the weather station is to insert the connector (RJ11) at the end of the wire attached to the wind speed 
sensor to the remote temperature/humidity sensor.  Please ensure when doing this that the connector is inserted with the proper 
orientation.  When seated properly you will hear the connector ‘click’ in place. 
 

A.

 

REMOTE TEMPERATURE/HUMIDITY SENSOR 

 

1.

 

Remove the mounting bracket and humidity hood. 

2.

 

Remove the battery cover by sliding the cover down. 

3.

 

Observing the correct polarity install 2 AA batteries.  The batteries will fit tightly (to avoid start-up problems make 
sure they do not spring free). 

4.

 

Replace the battery cover by sliding upwards. Be sure battery cover is on securely. 

5.

 

Replace the humidity hood. 

 

B.

 

INDOOR WEATHER STATION 

Содержание WS-9035TWC

Страница 1: ...WS 9035TWC Wireless 433 MHz Radio controlled Weather Station Instruction Manual...

Страница 2: ...etting the Time 8 Setting the Year Day and Month 9 Setting the Snooze 9 Setting the Temperature Format 9 Setting the Forecast Sensitivity 10 Features Weather Forecast Icons and Tendency Arrows 11 Indo...

Страница 3: ...continuously throughout the United States at 60 kHz The signal can be received up to 2 000 miles away through the internal antenna in the Weather Station However due to the nature of the Earth s Iono...

Страница 4: ...ugh will reduce distance An outdoor wall or window can have up to 30 feet of resistance and an interior wall can have up to 20 feet of resistance Your distance plus resistance should not exceed 300 ft...

Страница 5: ...correct time default time zone is Eastern You will need to adjust the time zone to match your local time PROGRAM MODE Programming Note If 30 seconds are allowed to pass or the WIND SNZ button is press...

Страница 6: ...Atlantic 4 EST Eastern 5 CST Central 6 MST Mountain 7 PST Pacific 8 ALA Alaska 9 HAW Hawaii 10 6 Press and release the SET button to confirm and advance to the Daylight Saving Time setting V DAYLIGHT...

Страница 7: ...tion is at night between midnight and 6 00 am when there is less atmospheric interference To keep your time as accurate as possible the indoor weather station conducts a WWVB search every night betwee...

Страница 8: ...t the duration of the snooze Note The snooze can be set for 0 to 30 minutes in 5 minute increments If 0 minutes is selected pressing the WIND SNZ button will deactivate the alarm and it will not come...

Страница 9: ...a necessity to disregard all weather forecasting for 12 24 hours after the unit has been set up reset or moved from one altitude to another i e from one floor of a building to another floor In areas w...

Страница 10: ...ator is located at the bottom left of the INDOOR LCD The indicator will display a happy face icon when the temperature is between 68 F and 79 F 20 C and 25 9 C and the humidity is between 45 and 64 A...

Страница 11: ...either MAX or MIN 2 Press and hold the SET button for 5 seconds 3 The record is now reset and will show the current time in the TIME LCD and current outdoor temperature and humidity in the OUTDOOR LC...

Страница 12: ...s and hold the WIND SNZ button for 3 seconds 2 The WIND SPEED LCD will now show the maximum wind 3 Press and release the WIND SNZ button again 4 The WIND SPEED LCD will now show the maximum wind gust...

Страница 13: ...3 18 mph 20 28 kph 11 16 knots Moderate Breeze Small branches move raises dust leaves and paper Small waves develop becoming longer whitecaps 5 19 24 mph 29 38 kph 17 21 knots Fresh Breeze Small trees...

Страница 14: ...ss and hold the ALM button for 5 seconds 2 The alarm time will begin to flash in the DATE LCD 3 Press and release the IN HR button to adjust the hour Note When in the 12 hour mode and setting an alarm...

Страница 15: ...RE HUMIDITY SENSOR The remote temperature humidity sensor can be mounted in several ways With the use of screws Using adhesive tape Using nylon straps A MOUNTING WITH SCREWS 1 Remove the mounting brac...

Страница 16: ...y 3 16 of an inch 5mm extended from the wall 2 Place the indoor weather station onto the screw using the hanging hole on the backside 3 Gently pull the indoor weather station down to lock the screw in...

Страница 17: ...absorb and store heat from external sources i e handling of the case or radiant heat Also the much greater range of the remote temperature humidity sensor requires a different calibration curve than...

Страница 18: ...ature checking interval Every 15 seconds Indoor humidity checking interval Every 20 seconds Outdoor temperature checking interval remote temperature humidity sensor Every 128 seconds Outdoor humidity...

Страница 19: ...erefore the above exclusion of limitation may not apply to you For warranty work technical support or information contact La Crosse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 F...

Отзывы: