background image

La Crosse Technology, Ltd.            www.lacrossetechnology.com/support 

Page 9 

 

 

When temperature alert sounds, the corresponding alert icon (bell) will flash. 

 

The alert beeps once every minute, until the temperature is out of alert range. 

 

Press any button to stop alert. The alert symbol will still show. 

 

Turn alert OFF:  In normal mode, hold and release the ALERT button to select the alert. 

With HI or LO alert selected, press the 

 button to disarm that alert. 

 

Weather Station 

 

Power Requirements 

 

 

This weather station is powered by a 5 volt AC adapter adapter  

 

Alternatively, optional 3-AAA alkaline batteries may be used. 

 

12-Hour or 24-Hour time format 

 

 

Time can display in 12-hour (am, pm) or 24-hour format.  

 

Default is 12-hour time. 

 

Use the 

Program Menu 

to switch time formats. 

 

Fahrenheit/Celsius 

 

 

  Use the 

program menu 

to switch between Fahrenheit and Celsius. 

 

Indoor Comfort Level Indicator 

 

The indoor comfort display is based off the humidity read by the weather station.  

The weather station will display one of five indicators: 

 

Too DRY (1-24%) 

 

DRY (25-39%) 

 

Comfort OK (40-70%) 

 

Wet (71-80%) 

 

Too Wet (81-97%) 

 

Backlight 

 

AC adapter: The backlight is on continuously when operating the weather station with the 

5-volt AC adapter. 

Note: When the AC adapter is NOT in use, the HI-LOW-OFF light feature is not available. 

  

 

HIGH: The backlight is defaulted to HI at setup when the AC adapter is in use. 

 

LOW: Press the HI-LOW-OFF button to dim the backlight.   

 

OFF: Press the HI-LOW-OFF button again to turn the backlight off.  

 

Press the HI-LOW-OFF button to return to full strength.  

Note: When the backlight is off, press any button to activate the backlight for 10 seconds.  

 

Battery power: When operating on battery power only, press and release the any button 

and the backlight will show for 10 seconds. 

 

Dashes, HH.H, LL.L or stuck Indoor Temperature/Humidity 

 

Explanation: These symbols are error messages indication the indoor sensor is outside of 

its readable range. For indoor readings, this is generally a power related issue.  

 

 

Check that the AC adapter cord is inserted into a working outlet. 

 

Batteries 

may be overpowered or underpowered. Remove batteries from the weather 

station.  

 

Press any button 20 times. Leave the weather station unpowered for 1-2 hours.  

Содержание T83653v2

Страница 1: ...mote Temperature 4 Remote Temperature is stuck or HH H LL L 4 Remote sensor drains batteries quickly 4 Remote Humidity goes to dashes when temperature is cold 5 Remote sensor fell The sensor no longer...

Страница 2: ...tteries in the remote sensor A minimum voltage of 1 48V for each battery is necessary for proper performance Use batteries dated at least six years in advance of the current year Batteries dated earli...

Страница 3: ...does not work please try the factory reset Remote Temperature Signal Strength Explanation The weather station will search for the remote temperature humidity remote sensor for 3 minutes after batteri...

Страница 4: ...s sensor Place the remote sensor in the freezer for an hour and watch the temperature drop on the weather station Indoor distance test Please complete the Restart with remote sensor and weather statio...

Страница 5: ...sensor that has fallen into puddle snow or other standing water will likely have water damage and need to be replaced Remote sensors are water resistant not waterproof Replacement Remote sensors Visit...

Страница 6: ...emperature is above 26 7 C 80 F Dew Point Temperature Dew Point Temperature is the saturation point of the air or the temperature to which the air has to cool in order to create condensation The highe...

Страница 7: ...wall Place the remote sensor onto the screw hanging hole on the backside Gently pull down to lock the screw in place Option 2 Insert the mounting screw through the front of the remote sensor and into...

Страница 8: ...door temperature alerts are set in two separate steps Set the alert value Arm Disarm the alert Select Temperature Alert Values Hold the ALERT button for five seconds to select and set temperature aler...

Страница 9: ...cators Too DRY 1 24 DRY 25 39 Comfort OK 40 70 Wet 71 80 Too Wet 81 97 Backlight AC adapter The backlight is on continuously when operating the weather station with the 5 volt AC adapter Note When the...

Страница 10: ...s and press ALARM button to confirm and exit Note When no buttons are pressed for ten seconds the weather station will save the last change and default back to normal mode Activate Deactivate time ala...

Страница 11: ...lect Fahrenheit or Celsius Confirm with the TIME SET button and exit Note When no buttons are pressed for ten seconds the weather station will save the last change and default back to normal mode Fore...

Страница 12: ...into the weather station Weather station is blank No letters numbers or dashed lines Check that the batteries are installed correctly Batteries may be overpowered or underpowered Remove batteries from...

Отзывы: