background image

La Crosse Technology, Ltd.            www.lacrossetechnology.com/support 

Page 3 

 

 

For optimum 433MHz transmission, place the remote sensor no more than 300 feet (91 

meters, open air) from the weather station. 

 

See the section on 

mounting 

and 

distance/resistance/interference 

for details on 

mounting the remote sensor. 

 

 

Remote Temperature Sensor 

 

Compatible Remote sensors 

 

 

The TX141TH-BCH remote sensor comes packaged with this weather station.  

 

The TX141TH-ACH (433MHz) remote sensor is compatible with this weather station.  

 

Quick Connect 

 

Explanation: Use the quick connect for a weather station and remote sensor that have 

been working but lost connection due to interference or low batteries. This is not the same 

as a thorough factory reset. 

 

1.

 

Bring the remote sensor and weather station together inside, and place the units 5-10 

feet apart with nothing between them.  

2.

 

Hold the INFO button for 5 seconds. The remote temperature area will flash. 

3.

 

Remove battery cover from the remote sensor and press and release the TX button to 

send the signal. 

4.

 

Wait for 2 minutes for the remote temperature to appear on the weather station. 

 

 

Factory Restart: 

If the above procedure does not work, please try the factory reset. 

 

Remote Temperature Signal Strength 

 

Explanation: The weather station will search for the remote temperature/humidity remote 

sensor for 3 minutes after batteries are installed or when the INFO button is held for 3 

seconds. 

 

 

The antenna symbol will flash during reception. 

 

The temperature display will be dashes “---“. 

 

If synchronization fails once, the antenna will lose one bar.  

 

If synchronization fails twice, the antenna will lose two bars.  

 

If RF (radio frequency) reception fails five times, the antenna symbol will show without 

bars.  

 

The antenna will show full display with successful RF (radio frequency) reception.  

 

Dashes show for Remote Temperature 

 

Explanation: Dashes mean the connection is lost between the weather station and the 

remote sensor.   

 

 

Batteries 

often resolve the connection. 

 

Distance/Resistance 

can cause loss of connection between the remote sensor and the 

weather station.  

 

Turn the weather station 90 degrees towards the remote sensor to provide better 

reception. This allows more antenna surface to face the remote sensor signal.  

 

Try the 

quick connect 

or 

factory restart.

 

 

Power Requirements 

 

 

2-AA

 batteries 

power the remote sensor.  

 

We recommend Alkaline batteries for the remote sensor. 

 

You may choose to use Lithium batteries for temperatures below -20°F/-28.8°C. 

 

Inaccurate Remote Temperature Reading 

 

Содержание T83653v2

Страница 1: ...mote Temperature 4 Remote Temperature is stuck or HH H LL L 4 Remote sensor drains batteries quickly 4 Remote Humidity goes to dashes when temperature is cold 5 Remote sensor fell The sensor no longer...

Страница 2: ...tteries in the remote sensor A minimum voltage of 1 48V for each battery is necessary for proper performance Use batteries dated at least six years in advance of the current year Batteries dated earli...

Страница 3: ...does not work please try the factory reset Remote Temperature Signal Strength Explanation The weather station will search for the remote temperature humidity remote sensor for 3 minutes after batteri...

Страница 4: ...s sensor Place the remote sensor in the freezer for an hour and watch the temperature drop on the weather station Indoor distance test Please complete the Restart with remote sensor and weather statio...

Страница 5: ...sensor that has fallen into puddle snow or other standing water will likely have water damage and need to be replaced Remote sensors are water resistant not waterproof Replacement Remote sensors Visit...

Страница 6: ...emperature is above 26 7 C 80 F Dew Point Temperature Dew Point Temperature is the saturation point of the air or the temperature to which the air has to cool in order to create condensation The highe...

Страница 7: ...wall Place the remote sensor onto the screw hanging hole on the backside Gently pull down to lock the screw in place Option 2 Insert the mounting screw through the front of the remote sensor and into...

Страница 8: ...door temperature alerts are set in two separate steps Set the alert value Arm Disarm the alert Select Temperature Alert Values Hold the ALERT button for five seconds to select and set temperature aler...

Страница 9: ...cators Too DRY 1 24 DRY 25 39 Comfort OK 40 70 Wet 71 80 Too Wet 81 97 Backlight AC adapter The backlight is on continuously when operating the weather station with the 5 volt AC adapter Note When the...

Страница 10: ...s and press ALARM button to confirm and exit Note When no buttons are pressed for ten seconds the weather station will save the last change and default back to normal mode Activate Deactivate time ala...

Страница 11: ...lect Fahrenheit or Celsius Confirm with the TIME SET button and exit Note When no buttons are pressed for ten seconds the weather station will save the last change and default back to normal mode Fore...

Страница 12: ...into the weather station Weather station is blank No letters numbers or dashed lines Check that the batteries are installed correctly Batteries may be overpowered or underpowered Remove batteries from...

Отзывы: