Explanation: High remote temperature readings are generally a location issue. Low remote 

temperature readings are power related or a sensors going bad. 

 

 

The remote sensor reads the environment where it is mounted. When mounted inside 

the home, it will read inside temperature/humidity. 

 

When the remote sensor reads high during the day, but not at night, it is a 

positioning

 

problem. 

 

Look for heat sources such as sunlight, door or window frames or reflected heat. 

 

Side-by-side test: Place the remote sensor right next to the weather station for 2 hours.  

 

Compare indoor and remote temperature. The temperatures should be within 4 degrees 

to be within tolerance.  

 

If the remote sensor reads correctly when next to the weather station, try a different 

location outside.  

 

Intermittent Remote Temperature 

 

Explanation: Intermittent problems are the hardest to resolve. RF (radio frequency) 

communication may come and go occasionally. This can be normal in some environments 

(e.g. moister climates). If remote sensor signal is lost, please wait 2-4 hours for the signal 

to reconnect on its own.  

 

 

Move the remote sensor to a closer location. 

 

Distance/Resistance 

can cause loss of remote sensor signal.  

 

Check 

Batteries

. 

 

Freezer test: Confirm the weather station is reading the correct remote sensor (not a 

neighbor’s sensor). Place the remote sensor in the freezer for an hour and watch the 

temperature drop on the weather station. 

 

Indoor distance test: Please complete the 

Restart 

with remote sensor and weather station 

5-10 feet apart and inside to establish a strong connection.  

 

After 15 minutes, if there is a reading in the remote temperature area, move the remote 

sensor to another room with one wall between the remote sensor and the weather 

station.  

 

Observe to see if the temperature remains on consistently for 1 hour.  

 

If the temperature remains on while in the house, then it is likely a 

distance/resistance 

issue.  

 

Move the remote sensor to different locations outside to find a location where the 

temperature reading will hold. 

 

Remote Temperature is stuck or HH.H, LL.L 

 

Explanation: These symbols are error messages indicating the remote sensor is outside of 

its readable range. 

 

 

Check 

Batteries.

 Overpowered or underpowered batteries can cause this reading. 

 

Replace remote sensor. 

Note: The last remote reading may remain (not change) for several hours when connection 

is lost. The remote temperature reading will flash when the connection is first lost or 

intermittent.  

 

Remote sensor drains batteries quickly 

 

 

Test a new set of alkaline batteries. Write down the date of installation and the voltage 

of the batteries. 

 

When the batteries fail, please note the date and voltage again.  

 

Check the 

distance

 and 

resistance

 between the remote sensor and weather station. 

Remote sensors at the end of the range may work while batteries are fresh but not after 

they drain a bit. 

Содержание T83653v2

Страница 1: ...mote Temperature 4 Remote Temperature is stuck or HH H LL L 4 Remote sensor drains batteries quickly 4 Remote Humidity goes to dashes when temperature is cold 5 Remote sensor fell The sensor no longer...

Страница 2: ...tteries in the remote sensor A minimum voltage of 1 48V for each battery is necessary for proper performance Use batteries dated at least six years in advance of the current year Batteries dated earli...

Страница 3: ...does not work please try the factory reset Remote Temperature Signal Strength Explanation The weather station will search for the remote temperature humidity remote sensor for 3 minutes after batteri...

Страница 4: ...s sensor Place the remote sensor in the freezer for an hour and watch the temperature drop on the weather station Indoor distance test Please complete the Restart with remote sensor and weather statio...

Страница 5: ...sensor that has fallen into puddle snow or other standing water will likely have water damage and need to be replaced Remote sensors are water resistant not waterproof Replacement Remote sensors Visit...

Страница 6: ...emperature is above 26 7 C 80 F Dew Point Temperature Dew Point Temperature is the saturation point of the air or the temperature to which the air has to cool in order to create condensation The highe...

Страница 7: ...wall Place the remote sensor onto the screw hanging hole on the backside Gently pull down to lock the screw in place Option 2 Insert the mounting screw through the front of the remote sensor and into...

Страница 8: ...door temperature alerts are set in two separate steps Set the alert value Arm Disarm the alert Select Temperature Alert Values Hold the ALERT button for five seconds to select and set temperature aler...

Страница 9: ...cators Too DRY 1 24 DRY 25 39 Comfort OK 40 70 Wet 71 80 Too Wet 81 97 Backlight AC adapter The backlight is on continuously when operating the weather station with the 5 volt AC adapter Note When the...

Страница 10: ...s and press ALARM button to confirm and exit Note When no buttons are pressed for ten seconds the weather station will save the last change and default back to normal mode Activate Deactivate time ala...

Страница 11: ...lect Fahrenheit or Celsius Confirm with the TIME SET button and exit Note When no buttons are pressed for ten seconds the weather station will save the last change and default back to normal mode Fore...

Страница 12: ...into the weather station Weather station is blank No letters numbers or dashed lines Check that the batteries are installed correctly Batteries may be overpowered or underpowered Remove batteries from...

Отзывы: