background image

18

Select different discharging current by pressing the CURRENT key (see “Note” in 
Discharge mode and Table 2), within 8 seconds after inserting the batteries. (Or the 
display will blink once to indicate the end of setting and the current cannot be changed 
afterward.).  

z

It may take up to several days to finish the refreshing process, depending on the selected 
discharging current. 

z

The maximum refresh current is 700 mA and is not affected by the number of 
rechargeable batteries inserted. 

TEST MODE   

In the Test mode the rechargeable batteries will first be fully charged and then discharged to 
determine the capacities. Finally, the rechargeable batteries are charged up again and the 
capacity in (mAh) or (Ah) will alternate every 3 seconds with the FULL sign.   
Press the MODE key within 8 seconds after inserting the rechargeable batteries; the Test mode 
can be selected. (Hold the MODE key for about 1 second to activate the mode change. Press 
and release the MODE key to select the “Charge”, “Discharge”, “Test” and “Refresh” mode)

19

NOTE: 

z

After selecting the Test mode the user may select different charging currents in the Test 
mode by pressing the CURRENT key, within 8 seconds after the batteries are inserted. 
The discharging current will be half of the selected charging current (see Table 3). 

Table 3. TEST MODE Current

User-selected Charging 

current 

200 mA 

500 mA 

700 mA 

Thereafter Discharging 

current 

100 mA 

250 mA 

350 mA 

Test mode 

The Charging 
current in (mA) 

20

z

The maximum charging current is 700 mA and is not affected by the number of 
rechargeable batteries inserted. 

z

After the test mode is finished, the display will shift between the “Full” sign and the 
battery capacity (in mAh or Ah) automatically in 3-second intervals until the rechargeable 
batteries are removed. The user can switch to other displays by pressing the DISPLAY 
key. 

TRICKLE CHARGING 

After the rechargeable battery is fully charged in any of the operating modes, the charger will 
give a small amount of current to the rechargeable batteries to maintain the fully charged level. 
This mode is automatically launched after rechargeable batteries are fully charged and kept in 
the charging unit. The signal “Full” will be displayed on the LCD.   

Battery capacity displayed in 
(mAh) as the checking is 
finished in Test mode.     

21

DISPLAY MODE INFORMATION 

The user can use different display modes to monitor the rechargeable battery condition during 
the different operations (see below figure and Table 4 to 7). 

Different operating modes 

Different display modes are 
exhibited: Charging current, Time, 
Voltage and Capacity

22

Table 4. Various displays in Charge Mode

Stage in 

Charge mode

Various displays (toggled by pressing DISPLAY key)

Voltage (V) 

Current (mA)

*Time 

(hh:mm) 

Capacity

(mAh/ Ah) 

During 

charging 

Instantaneous 

Battery voltage 

Charging 

current 

Charging time 

elapsed 

Accumulated 

capacity 

Full stage 

Trickle 

charging 

current 

Capacity: 

Milliamp hours: 

mAh

 is the capacity of the battery or the amount of charge added to a battery. If 

a 2600mAh capacity battery is already half full when you charge it you will not add 2600mAh of 
capacity to the battery. 

Amp hours: 

Ah

 is the capacity of the battery or the amount of charge added to a battery. When 

the battery charger shows values above 1999mAh, it changes to Amp hours. Due to the limited 
space on the four displays the charger cannot display over 1999mAh. When the mAh 

23

(Milliampere hour) reaches 2000 the display switches to Ah (Ampere hour) by moving the 
decimal point. A mAh is 1/1000 of an Ah. Example: 2.29Ah and 2.34 Ah would be 2290mAh and 
2340 mAh.

Table 5. Various displays in Discharge Mode

Stage in 

Discharge mode

Various displays (toggled by pressing DISPLAY key)

Voltage (V) 

Current (mA) 

*Time (hh:mm) 

Capacity

(mAh/ Ah) 

During 

discharging 

Instantaneous 

Battery voltage 

Discharging 

current 

Discharging time 

elapsed 

Capacity during 

discharging 

During charging 

Charging current

Charging time 

elapsed 

Accumulated 

capacity 

Full stage 

Trickle charging 

current 

Содержание BC-700U

Страница 1: ...se any power cable and transformer other than those originally supplied with the charging unit 6 The rechargeable batteries may become hot during charging especially when a high charging current is chosen User should take extra care when taking out the batteries after charging 7 Unplug the charging unit from the power source when not in use 4 FEATURES The Charging unit z Charging rechargeable batt...

Страница 2: ...charging current is tabulated in Table 1 NOTE It is acceptable to charge AA and AAA batteries at the same time Table 1 Charging Time with various charging current Size of battery Battery Capacity Charging current selected mA Estimated charging time AA 2500 mAh 700 3 hr 35 min 500 5 hr 200 13 hr AAA 700 mAh 700 60 min 500 84 min 200 3 hr 30 min NOTE z Always observe the recommended maximum charging...

Страница 3: ... For a new rechargeable battery it is recommended to charge it with 200 mA current to re condition it from the long storage status DISCHARGE MODE Discharge mode will first discharge the rechargeable battery then charge it It is for removing the memory effects of rechargeable batteries When the battery is overheated the charging will cease automatically 000 mA will be displayed 15 Press the MODE ke...

Страница 4: ...attery is fully charged in any of the operating modes the charger will give a small amount of current to the rechargeable batteries to maintain the fully charged level This mode is automatically launched after rechargeable batteries are fully charged and kept in the charging unit The signal Full will be displayed on the LCD Battery capacity displayed in mAh as the checking is finished in Test mode...

Страница 5: ...only damage the unit Charging current range 200 mA 700 mA Max charging capacity capacity of rechargeable batteries 3000 mAh Dimensions H x W x D Charging unit 2 95 x 5 11 x 1 57 75 x 130 x 40 mm 28 LIABILITY DISCLAIMER z The manufacturer and supplier cannot accept any responsibility for any improper or incorrect use and any consequences occur z Any performance of repairs or alternations by someone...

Страница 6: ... right Æ Æ Steps Plug in Place batteries in charger Select mode Hold for 5 10 seconds to activate Select Charge to select current level Display Blinks To change or mode during charging To Change amount of charge or current repeat all steps from beginning 33 notes Select Charge Discharge Refresh Test Current 200 to 700 varies by number and type Indicate no more chance to change Press de MODE key fo...

Страница 7: ...city Maximum charging capacity is 3000 mAh 39 My batteries are getting warm It is common for batteries to get warm will charging The charger has a built in temperature sensor which will stop the charging cycle if it has become too hot Charging may resume when the battery has cooled Allow batteries to cool before placing into a product to be used I cannot change modes Within 8 seconds of installing...

Страница 8: ...or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged ...

Отзывы: