Compartment Number key 

Press and release the Number key to select a particular battery compartment for charge modes 
and/or display mode adjustment.   

MODE key   

Hold the MODE key for about 1 second to activate the mode change. Press and release the 
MODE key to toggle between the “Charge”, “Discharge”, “Test” and “Refresh” mode. To change 
the operating mode for an individual rechargeable battery, first press the corresponding 
NUMBER key then press the MODE key.   

DISPLAY key 

Press and release the DISPLAY key to view: Charging current (in mA), Time elapsed (in hh:mm), 
the Terminal voltage (in V) and Accumulated capacities (in mAh or Ah) during the charging or 
discharging process. To change the display content of an individual rechargeable battery, first 
press the corresponding NUMBER key then press the DISPLAY key. 

CURRENT key 

Press and release the CURRENT key to select the amount of current to be applied (within the 
first 8 seconds after batteries are inserted) in different operating modes (also see “

Start 

7

charging the rechargeable batteries

” below). To change the charging current of an individual 

rechargeable battery, first press the corresponding NUMBER key then press the CURRENT key 
(within the first 8 seconds after batteries are inserted). 

OPERATING MODES OF THE CHARGING UNIT 

This powerful charging unit provides the following operating modes: 
a. 

Charge the rechargeable battery 

(CHARGE)

 – to charge the rechargeable battery, 

automatically switches to trickle charge after the rechargeable battery is full. 

b. 

Discharge then charge the rechargeable battery 

(DISCHARGE)

 – to discharge the 

rechargeable battery then charge it to minimize the memory effect. 

c. 

Refresh the rechargeable battery 

(REFRESH)

 – to refresh the rechargeable battery to its 

maximum capacity by charging and discharging the rechargeable battery repeatedly until 
no further increase in the capacity is estimated. For old rechargeable batteries or those 
have not been used for a long time, refreshing may bring the rechargeable battery back 
to the optimum condition.   

d. 

Check the rechargeable battery capacity in mAh/ Ah 

(TEST)

8

CHARGE MODE   

Charging at 200 mA is the default-operating mode of the charging unit.   

NOTE:

 The highest charging current will be in compartment 1. The other compartments cannot 

be higher. 

Example: 

When charging four batteries – 
max. charging current: 700 mA 

When charging two batteries at 
compartment 2 & 3 – max. 
charging current: 700 mA 

9

The estimated time of charging by various charging current is tabulated in Table 1. 

NOTE

: It is acceptable to charge AA and AAA batteries at the same time. 

Table 1. Charging Time with various charging current

Size of battery Battery Capacity Charging current selected (mA) Estimated charging time 

AA 2500 

mAh 

700 

~3 hr 35 min 

500 ~5 

hr 

 

200 ~13 

hr 

 

AAA 700 

mAh 

700 ~60 

min 

500 ~84 

min 

200 

~3 hr 30 min 

NOTE:

z

Always observe the recommended maximum charging current of the rechargeable 
batteries. In general, 200 mA is a recommended charging current if rapid charging is not 
necessary. It is definitely safe and optimum to the life of the rechargeable batteries. 

10

z

It may be necessary to charge and discharge new rechargeable batteries several times in 
the beginning before the optimum capacity of the rechargeable batteries can be 
obtained. Use the "Refresh" mode after new rechargeable batteries have been used 
under load and charged several times in order to achieve the optimum battery capacity.   

z

When the transformer has been plugged into the power source, the version number of 
the charger (for example “35”) will be displayed first. Then all the segments will light up 
momentarily and the “null” sign will be shown before batteries are placed. If damaged 
batteries or batteries below 0.9V, are placed into the charging unit, the charger will also 
show “null” on LCD. 

START CHARGING THE RECHARGEABLE BATTERIES

Once a rechargeable battery is inserted after the transformer has been plugged into the power 
source, the battery voltage (for example, “1.39V”) will be displayed for 4 seconds. Then “200 mA 

“null” displayed - No battery or damaged battery 
is placed to the charging unit

11

Charge” (default mode) will be shown on LCD for another 4 seconds, indicating that charging 
with 200 mA is to be started if no alteration in setting is made.   

Select the operating mode by the MODE key. “Charge”, “Discharge”, “Refresh” and 
“Test” mode may be chosen within this 8-second time after inserting the batteries. 
Then within 8 seconds from pressing the last key, select the charging/discharging 
current by pressing the CURRENT key. 

NOTE:

z

Hold the MODE key for about 1 second to activate the mode change. Press and release 
the MODE key to select between the “Charge”, “Discharge”, “Test” and “Refresh” mode.   

z

There is an 8-second time allowed for choosing further functions after each key pressing. 
If no keys are pressed, the LCD will blink one time to indicate the end of setting. The 
current can no longer be changed during the process and the selected mode will begin.     

Charging current: 200 mA   

Charge Mode 

After 8 seconds from the last key 
press, the LCD will blink once to 
indicate the setting is confirmed and 
the selected mode is activated   

Содержание BC-700U

Страница 1: ...se any power cable and transformer other than those originally supplied with the charging unit 6 The rechargeable batteries may become hot during charging especially when a high charging current is chosen User should take extra care when taking out the batteries after charging 7 Unplug the charging unit from the power source when not in use 4 FEATURES The Charging unit z Charging rechargeable batt...

Страница 2: ...charging current is tabulated in Table 1 NOTE It is acceptable to charge AA and AAA batteries at the same time Table 1 Charging Time with various charging current Size of battery Battery Capacity Charging current selected mA Estimated charging time AA 2500 mAh 700 3 hr 35 min 500 5 hr 200 13 hr AAA 700 mAh 700 60 min 500 84 min 200 3 hr 30 min NOTE z Always observe the recommended maximum charging...

Страница 3: ... For a new rechargeable battery it is recommended to charge it with 200 mA current to re condition it from the long storage status DISCHARGE MODE Discharge mode will first discharge the rechargeable battery then charge it It is for removing the memory effects of rechargeable batteries When the battery is overheated the charging will cease automatically 000 mA will be displayed 15 Press the MODE ke...

Страница 4: ...attery is fully charged in any of the operating modes the charger will give a small amount of current to the rechargeable batteries to maintain the fully charged level This mode is automatically launched after rechargeable batteries are fully charged and kept in the charging unit The signal Full will be displayed on the LCD Battery capacity displayed in mAh as the checking is finished in Test mode...

Страница 5: ...only damage the unit Charging current range 200 mA 700 mA Max charging capacity capacity of rechargeable batteries 3000 mAh Dimensions H x W x D Charging unit 2 95 x 5 11 x 1 57 75 x 130 x 40 mm 28 LIABILITY DISCLAIMER z The manufacturer and supplier cannot accept any responsibility for any improper or incorrect use and any consequences occur z Any performance of repairs or alternations by someone...

Страница 6: ... right Æ Æ Steps Plug in Place batteries in charger Select mode Hold for 5 10 seconds to activate Select Charge to select current level Display Blinks To change or mode during charging To Change amount of charge or current repeat all steps from beginning 33 notes Select Charge Discharge Refresh Test Current 200 to 700 varies by number and type Indicate no more chance to change Press de MODE key fo...

Страница 7: ...city Maximum charging capacity is 3000 mAh 39 My batteries are getting warm It is common for batteries to get warm will charging The charger has a built in temperature sensor which will stop the charging cycle if it has become too hot Charging may resume when the battery has cooled Allow batteries to cool before placing into a product to be used I cannot change modes Within 8 seconds of installing...

Страница 8: ...or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged ...

Отзывы: