- the phase (red or brown wire) to P1
- the ground to T (yellow / green)
- For a
3-phase 400 V
power supply, remove the shunt from the P1, P2 and P3
terminals, and then connect the cable wires as follows:
- neutral (blue wire) to N
- the three other wires (red or brown) to the P1, P2 and P3 terminals.
- the ground to T (yellow / green)
Ensure that the cross-section of the electrical cables corresponds to that
indicated in the tables in the general description for each appliance.
Our appliances are supplied with injectors corresponding to the type of gas supply specified
in your order (natural gas, butane or propane) and according to the country where the
cooker is to be installed.. These injectors should only be changed if a different type of gas
is used.
However, it may be necessary to adjust or change the “by-pass” screw. See page 39 for the
table summarizing the injectors to be used for each type of gas, the country of installation
and injector replacement instructions.
If no particular instructions are specified in the order, the appliance is equipped with
injectors for natural gas G20 (pressure: 20 mbar).
The type of gas for which the appliance is equipped, is indicated on a label at the rear
of the appliance, near the gas supply pipe.
The gas connection must be done in keeping with the installation rules in force
in the country where the appliance is to be used.
Connection to the previously installed shut-off valve must be made using a flexible hose
with screwable connectors, approved.
The characteristics of this hose must be tailored to the nature and distribution mode of the
gas used, as well as to the diameter of the connection used.
The hose must not pass behind, in front of or close to a hot air outlet. It must be put down
so as not to be reachable by flames. It must not be crushed or kinked, and must be put
down so as to avoid all pulling stress.
The hose must be firmly attached at both ends, and it must be possible to inspect the com-
plete hose length. Moreover, the hose should be replaced by the user whenever required
and, in all cases, before the maximum use date given on the hose.
Recommended use: metallic flexible hose (stainless steel surrounded by metallic
braids) with screwable connectors, without any lifetime end date.
Regardless of the gas used, it is forbidden to connect our gas appliances with flexible hoses
mounted on rubber tail pieces.
2. G
AS CONNECTION
28
Notice d’installation ligne “Cornuchef” Centenaire - GB
08NOTINSTGSC100/GB-4
CONNECTIONS
Gas connection