27
Electrical connections
CONNECTIONS
accordance with its environment or your own requirements.
Each cooker is equipped with adjustable feet that allow you to compensate for differences
in the floor level.
REMINDER: Ceramic cardboard with a minimum thickness of 20mm. must be
installed under the cooktop to insulate the units placed underneath.
" La Cornue " appliances are supplied with 1 – 4 flexible cords, P/N: H07 RN-F, consisting
of 3 or 5 wires, approximately 1.5 m long, ready to be connected to a single-phase or 3-
phase + n ground power supply, depending on the indications specified on the
order form (see the table corresponding to each model for the power ratings).
If the wire is damaged, it must be replaced by the manufacturer, its after sales
services or qualified persons in order to avoid hazard.
All of the electricity supply circuits must be disconnected before accessing the
connection terminal boxes.
REMINDER: the appliance should be connected to the main power supply via terminal
blocks and not by means of simple plugs.
Insert the cable below the hot air outlets at the back of the oven, never in front of them.
Should your appliance be connected to a different type of power supply at a later date, in
some cases (please contact our technical department before) it will be possible to change
the cabling accordingly, according to the following instructions:
- Unscrew the protection plate from the back of the appliance in order to access the
connection terminal block(s) to which the various heating elements are connected (if
there are 2, 3 or 4 supply cables on the cooker, there are also 2, 3 or 4 connection terminal
blocks).
220 - 240 V – single-phase
400 V – 3-phase
- For a
single-phase 220 - 240 V
power supply, shunt the P1, P2 and P3 terminals,
and then connect the cable wires as follows:
- neutral (blue wire) to N
1. E
LECTRICAL CONNECTIONS
C
ONNECTIONS
Notice d’installation ligne “Cornuchef” Centenaire - GB
08NOTINSTGSC100/GB-4
T = Ground
N = Neutral
Ph1 = Phase 1
Ph2 = Phase 2
Ph3 = Phase 3