Page
49
LA CORNUE
Installation Guide Centenaire
08NOTINSTAL100/USA-5
USA & C
AN
AD
A
Save the orifices removed from the appliance for future use.
If the range is to be used above 3000ft the burner orifices must be changed. This conversion must
be performed by a qualified gas installer.
Read the instructions before converting this appliance.
Failure to convert the appliance correctly could invalidate any warranty or liability claims and lead
to prosecution.
When servicing or replacing gas-carrying components disconnect from gas before commencing
operation.
Use the correct orifices for high altitude given by La Cornue service only for your appliance.
When you have completed the changes, check the appliance is gas sound.
CAUTION: DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.
Do not use re-conditioned or unauthorised gas controls.
Save the orifices removed from the appliance for future use.
Check operation of all the burners.
After conversion the installation must comply with the relevant regulations and also the local
electricity supply company requirements.
Remove the brisk heat grill (A), the cap of the burner (B), then the pan (C). The regulator is now
accessible.
The regulator has a bayonet mounted top cap. Using a small coin press in and turn the cap to
remove it. Turn the cap over so that the letters “LP” (for propan gas) or “NAT” (for natural gas) are
visible on base of the hollow in the cap. Replace the cap making sure that the bayonet pins are
securely located
M
AINTENANCE
Gas Pressure Regulator
WARNING
The conversion kit shall be installed by a qualified service
agency in accordance with the manufacturer's instructions
and all applicable codes and requirements of the authority
having jurisdiction. If the information in these instructions
is not followed exactly, a fire, explosion or production of
carbon monoxide may result causing property damage,
personal injury or loss of life. The qualified service agency
is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation
of the converted appliance is checked as specified in the
manufacturer's instructions supplied with the kit.
4. G
AS
P
RESSURE
R
EGULATOR
3. C
ONVERTING FOR
H
IGH
A
LTITUDE