Page
43
LA CORNUE
Installation Guide Centenaire
08NOTINSTAL100/USA-5
USA & C
AN
AD
A
The burners on the stoves of the "La Cornue" line are fitted with safety thermocouples: should a
burner extinguish, the gas supply to this burner
is automatically cut off.
Upon initial test of unit
When first testing the gas operated burners, you may find they do not operate.
This is
normal
, and is caused by air in the gas lines. Simply, operate each burner
starting with the
top burners,
until all the air is displaced by the gas and ignition will result. This may take 1
to 5 minutes.
On first use, the electronic safety device of the gas oven may switch on (the red indicator light
goes on).
Please press the reset button (B) until air is also displaced in the oven and the flame goes on.
1. T
ESTS
O
O
P
P
E
E
R
R
A
A
T
T
I
I
O
O
N
N
O
PERATION
Test
The appliance must be connected to the type of gas shown on the rating plate
of the appliance.
The gas supply line must be at least a 1/2 inch pipe.
On all pipe joints use sealing compound that does not react to propane gas.
Check gas leaks by using a liquid leak detector.
Do not use an open flame
INSTALLER
Leave this manual with the appliance and advise
the customer to keep it for future reference.
Inform the consumer of the location of the
gas shut-off valve.
Note: Propane gas cylinders must never be
located inside your home.