Model FA2100 CVR
Instruction Manual
Installation & Operation
Jan. 01/03
Rev. 07
Page B–24
165E1846–00
Conditions
Description of Conducted Tests
RTCA/DO–160C
Section
Fluids Susceptibility
11.0
Equipment identified as Category X, no test
required.
Sand and Dust
12.0
Equipment identified as Category X, no test
required.
Fungus Resistance
13.0
Identified as Category F. Composed of non-
nutrient materials or materials that are treated
in a manner that renders them non-nutrient.
Salt Spray
14.0
Equipment identified as Category X, no test
required.
Magnetic Effect
15.0
Equipment tested to Category Z.
Power Input
16.0
Equipment identified as Category X, no test
required.
Voltage Spike
17.0
Equipment identified as Category X, no test
required.
Audio Frequency Susceptibility
18.0
Equipment identified as Category X, no test
required.
Induced Signal Susceptibility
Magnetic Fields
Magnetic Fields
Electric Fields
Spikes
19.0
19.3.1
19.3.2
19.3.3
19.3.4
Equipment tested to Category Z.
Equipment
Cables
Cables
Cables
Radio Frequency Susceptibility
(Conducted and Radiated)
20.0
Equipment tested to Category T.
Emission of Radio Frequency Energy
Conducted
Radiated
21.0
21.3b
21.4
Equipment tested to Category Z.
Current probe method
Lightning Induced Transient
Susceptibility
22.0
Equipment tested to Category XXZ2.
Lightning Direct Effects
23.0
Equipment identified as Category X, no test
required.
Icing
24.0
Equipment identified as Category X, no test
required.
Notes:
1. Category F2 does not contation decompression and overpressure requirements, while Category
A2 does. L3AR has elected to perform Category A2 decompression at Category F2 altitude
parameters and Category A2 overpressure.