Instruction Manual
Installation & Operation
Model FA2100 CVR
165E1846–00
Jan. 01/03
Rev. 07
Page 5
Previously recorded information cannot be read from the Model FA2100 CVR while it is installed in the
aircraft. (Refer to paragraph 6.0 for additional information.)
Table 2. Model FA2100 CVR Recording Specifications
FA100CVR
Cockpit Audio Inputs
Combined Channels
FA100CVR
Part Number
Channel 1
Channel 2
Channel 3
Channel 4
Combined
Audio SQ
CAM SQ
3rd Crew
Member/Spare
Audio Input
for High Qual-
ity Recording
Co-Pilot Au-
dio Input for
High Quality
Recording
Pilot Audio
Input for High
Quality
Recording
Cockpit Area
Microphone
(CAM) Input
for High Qual-
ity Recording
Summation of
CH 1, 2, & 3
Audio Inputs
for Standard
Quality Re-
cording
Cockpit Area
Microphone
(CAM) (CH 4)
Input for Stan-
dard Quality
Recording
2100–1010–( )
30 minutes
30 minutes
30 minutes
Not Available
Not Available
2100–1020–( )
30 minutes
30 minutes
30 minutes
30 minutes
120 minutes
120 minutes
Note:
All of the times in the above table are minimum recording times. Unit can record
input audio levels from .05Vrms – 3.0Vrms. Nominal input level is 1.0 Vrms.
1.4.2 Control Units and External Preamplifier
The Control Unit or External Preamplifier is a required component of a CVR installation and functions as
the FA2100 CVR cockpit user interface. Control Units contain a preamplifier printed wiring assembly
(PWA) for interfacing the cockpit area microphone with the FA2100 CVR, and provide a means for
activating the test function via a green push button and an indicator. Bulk Erasure of the FA2100 CVR
storage media is also accomplished by pressing the Control Unit’s red Bulk ERASE push button. All
Control Units contain a headset jack for verifying system operation.
The Model S151/S161, Model S152/S162, and the Model S251/S261 Control Units are for use in
FA2100 CVR ARINC–757 / ED–56A System installations. The Model S151 and Model S251 Control
Units house the Microphone Preamplifier PWA, and have front panel TEST and Bulk ERASE switches.
The Model S151/S251 Control Units are used with an externally-mounted electret condenser-type
microphone (Model S055, see paragraph 1.4.3).
The Model S161/S261 Controls Units are used with remote microphone modules with internal amplifiers
for reducing RF interference (Model S056, see paragraph 1.4.3). These control units also have front
panel TEST and Bulk ERASE switches, TEST indicator lamp and a HEADSET jack.
The Model S152/S162 contains a built-in electret condenser-type microphone, Microphone Preamplifier
PWA, TEST and Bulk ERASE switches, TEST indicator lamp and a HEADSET jack.
The Model S150/S160 Preamplifier is available for FA2100 CVR ED–56A System installations that do
not require a Control Unit. However, because ARINC Characteristic 757 does not address microphone
preamplifiers, the Model S150/S160 Preamplifier is not considered ARINC–757 compliant. The S150 is
designed to be used with the S055 remote microphone. The S160 is used with the S056 remote
microphone.
The FA2100 CVR is compatible with installations using the Model A151B and A152B Control Units;
however, such installations do not comply with ARINC Characteristic 757 or EUROCAE ED–56A. The