L.B. White Tradesman 400 Скачать руководство пользователя страница 6

Propane gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks.
If a gas leak occurs, you should be able to smell the fuel gas.  
THAT’S  YOUR  SIGNAL  TO  GO  INTO  IMMEDIATE  ACTION!

Do not take any action that could ignite the fuel gas.  Do
not operate any electrical switches.  Do not pull any
power supply or extension cords.  Do not light matches
o r   a ny   ot h e r   s o u rc e   o f   f l a m e .     D o   n ot   u s e   yo u r
telephone.

Get everyone out of the building and away from the area
immediately.

Close all propane gas tank or cylinder fuel supply valves,
or the main fuel supply valve located at the meter if you
use natural gas.

Propane gas is heavier than air and may settle in low
areas.  When you have reason to suspect a propane
leak, keep out of all low areas.  

Use your neighbor’s phone and call your fuel gas 

supplier and your fire department.  Do not re-enter the
building or area.

Stay out of the building and away from the area until
declared safe by the firefighters and your fuel gas 

supplier.

FINALLY,  let the fuel gas ser vice person and the
firefighters check for escaped gas.  Have them air out
the building and area before you return.  Properly
trained service people must repair the leak, check for
further leakages, and then relight the appliance for you.

Some people cannot smell well.  Some people cannot
smell the odor of the man-made chemical added to
propane or natural gas.  You must determine if you can
smell the odorant in these fuel gases.  

Learn to recognize the odor of propane gas and natural
gas.  Local propane gas dealers will be more than happy
to give you a scratch and sniff pamphlet.  Use it to
become familiar with the fuel gas odor.  

Smoking can decrease your ability to smell.  Being
around an odor for a period of time can affect your
sensitivity to that particular odor.

The odorant in propane gas and natural gas is colorless
and the intensity of its odor can fade under some
circumstances.

If there is an underground leak, the movement of gas
through the soil can filter the odorant.  

Propane gas odor may differ in intensity at different
levels.  Since propane gas is heavier than air, there may
be more odor at lower levels.

Always be sensitive to the slightest gas odor. If you
continue to detect any gas odor, no matter how small,
treat it as a serious leak.  Immediately go into action as
discussed previously.

5

Safety Precautions

FUEL GAS ODOR

ODOR FADING -- NO ODOR DETECTED

ATTENTION -- CRITICAL POINTS TO REMEMBER!

Propane gas has a distinctive odor.  Learn to recognize
these odors.  (Reference Fuel Gas Odor and Odor Fading
sections above.

If you have not been properly trained in repair and service
of propane gas then do not attempt to light heater,
perform service or repairs, or make any adjustments to
the heater on the propane gas fuel system.

Even if you are not properly trained in the service and
repair of the heater, ALWAYS be consciously aware of
the odors of propane gas and natural gas.

A periodic sniff test  around the heater or at the heater’s
joints; i.e. hose, connections, etc., is a good safety
practice under any conditions.  If you smell even a small
amount of gas, CONTACT YOUR FUEL GAS SUPPLIER
IMMEDIATELY.  DO NOT WAIT!

WARNING

Asphyxiation Hazard

Do not use this heater for heating human living
quarters.

Do not use in unventilated areas.

The flow of combustion and ventilation air must not be
obstructed.

Proper ventilation air must be provided to support the
combustion air requirements of the heater being used.

Lack of proper ventilation air will lead to improper
combustion.

Improper combustion can lead to carbon monoxide
poisoning leading to serious injury or death.  Symptoms
of carbon monoxide poisoning can include headaches,
dizziness and difficulty in breathing.

Proper ventilation air for combustion must be provided
in accordance with OSHA 29 CFR 1926.154, Temporary
Heating Devices, ANSI A10.10, Safety Requirements for
Temporary and Portable Space Heating Devices, or the
Natural Gas and Propane Installation Code, CAN/CSA
B149.1 as appropriate. 

Содержание Tradesman 400

Страница 1: ...hite com ATTENTION ALL USERS This heater has been tested and evaluated by C S A International in accordance with the requirements of Standard ANSI Z83 7 CSA 2 14 and is listed and approved as a direct...

Страница 2: ......

Страница 3: ...d to property damage personal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury...

Страница 4: ...s Owner s Manual includes all options and accessories commonly used on this heater When calling for technical service assistance or for other specific information always have model number configuratio...

Страница 5: ...Gas 6 ft 1 83 m SPECIFICATIONS Model Electrical Supply Volts Hz Phase Amp Draw Dimensions Inches L x W x H Minimum Safe Distances From Nearest Combustible Materials STARTING CONTINUOUS OPERATION Fuel...

Страница 6: ...nder some circumstances If there is an underground leak the movement of gas through the soil can filter the odorant Propane gas odor may differ in intensity at different levels Since propane gas is he...

Страница 7: ...Forced air heaters shall not be directed toward any propane gas container within 20 feet 6 10 meters Do not wash the heater Use only compressed air a soft brush or dry cloth to clean the interior of t...

Страница 8: ...nd clear while the main burner ignites to prevent injury caused from hidden leaks that could cause flashback With the main burner in operation check all connections hose connections fittings and joint...

Страница 9: ...and defective parts replaced immediately The heater must be retested by properly qualified service personnel before placing the heater back into use PROPANE GAS SUPPLY SIZING The vaporization of prop...

Страница 10: ...nsert POL stem into the valve on the tank Thread the nut counterclockwise into the tank valve Tighten the nut securely with a wrench See Fig 4 2 Slowly open the tank valve This will prevent lock up of...

Страница 11: ...urer s recommended burner manifold pressure for size orifice used Ensure that the primary air supply to heater is open and free of dust dirt and debris for complete proper combustion If the heater is...

Страница 12: ...no cost A nominal charge will be applied for wiring diagrams Maintenance Instructions 1 Before cleaning shut off all gas supply valves and disconnect electrical supply 2 The heater should have dirt or...

Страница 13: ...check for gas leaks 9 Clean the heater s orifice with compressed air or a soft dry rag Do not use files drills broaches etc to clean the orifice Doing so may enlarge the hole causing combustion or ign...

Страница 14: ...contacts of the switch opening 3 Allow the switch to cool The switch contacts will close Check for electrical continuity across the switch terminals to ensure contacts have closed FIG 10 AUTO RESET B...

Страница 15: ...UT BOWED RETAINING CLIP SMALLER HOLE ALIGNED TO IGNITER GAP MAINTENANCE 1 Using a small wire brush reach down the barrel of the heater and brush the igniter electrode Ensure buildup is removed 2 Test...

Страница 16: ...rom heater FIG 19 THERMOSTAT IGNITION CONTROL 14 15 1 Disconnect the LED wire harness from the circuit board if applicable 2 Disconnect the ignition cable and remove the nuts securing the control to t...

Страница 17: ...and start the heater FIG 22 C Reading Pressures 1 With the heater operating the pressure gauge must read the pressures specified on the dataplate 2 Does the reading at the gas control valve agree wit...

Страница 18: ...Lights But Does Not Stay Lit 24 Components should be replaced only after each step has been completed and replacement is suggested in the flow chart Refer to the Servicing sections as necessary to obt...

Страница 19: ...voltage supplied to heater power cord Check extension cords and circuit breakers Repair extension cord reset breaker or call qualified electrician No 18 Problem Defective ignition control Does thermos...

Страница 20: ...and closed positions Yes If air proving switch is bypassed remove the bypass and retest Replace the switch if necessary One Time Air proving switch contacts are closed before fan motor starts Is air...

Страница 21: ...gnition control Defective motor Does ignition control send voltage to air proving switch Is ignition control receiving proper voltage No Is proper voltage supplied to heater power cord Defective ignit...

Страница 22: ...ernal board fault If module resets then have qualified electrician check power source for power quality problems Frequency line noise line spikes loose connections too small wire gauge Flame sense rel...

Страница 23: ...ed to ignition control Defective thermostat Is voltage supplied to air proving switch from the ignition control Defective Ignition Control Does fan motor start Check for voltage from ignition control...

Страница 24: ...rk Is high voltage lead securely connected to ignition control and ignitor Connect high voltage lead Is ignitor properly gapped Check igniter gap Regap to 3 16 in Is ignitor gap positioned toward burn...

Страница 25: ...iter if needed No Connect high voltage lead 24 TRADESMAN HEATER Problem Is proper fuel supplied to heater inlet Connect proper gas supply to heater Open all gas shutoff valves No Is proper gas pressur...

Страница 26: ...Electrical Connection and Ladder Diagrams 25 TRADESMAN 400 TRADESMAN 400 ULTRA...

Страница 27: ...fresh air into the heater and blow it into room for heating Gas Control Solenoid Valve House an electromagnet which is energized by voltage and opens to allow passage of gas to the burner orifice Gas...

Страница 28: ...27 PARTS SCHEMATIC Parts Identification...

Страница 29: ...ve 572551 14 Manifold tube with fittings 572570 15 Ignition control 571344 16 Ignition cable high voltage 571263 17 Igniter 573196 18 Backflash switch with hardware 572571 19 Combustion chamber with b...

Страница 30: ...nths of the date code marked on the part If the defect occurs more than 24 months later than the date code but within 24 months from the date of purchase by the end user a copy of a bill of sale will...

Отзывы: