Do not attempt to install, repair, or service this heater
or the gas supply line unless you have continuing
expert training and knowledge of gas heaters.  

Qualifications for service and installation of this
equipment are as follows:

a. To be a qualified gas heater service person, you

must have sufficient training and experience to
handle all aspects of gas-fired heater installation,
service and repair.  This includes the task of
installation, troubleshooting, replacement of
defective parts and testing of the heater.  You must
be able to place the heater into a continuing safe
a n d   n o r m a l   o p e r a t i n g   c o n d i t i o n .     Yo u   m u s t
completely familiarize yourself with each model
heater by reading and complying with the safety
instructions, labels, Owner’s Manual, etc., that is
provided with each heater.

b. To be a qualified gas installation person, you must

have sufficient training and experience to handle
all aspects of installing, repairing and altering gas
lines, including selecting and installing the proper
equipment, and selecting proper pipe and tank size
to be used.  This must be done in accordance with
all local, state and national codes as well as the
manufacturer’s requirements.

c.

In the Commonwealth of Massachusetts, this
product must be installed by a gas fitter licensed
by the Commonwealth of Massachusetts.

2.

All installations and applications of L.B. White heaters
must meet all relevant local, state and national codes.
Included are L.P. gas, natural gas, electrical, and
safety codes.  Your local fuel gas supplier, a local
licensed electrician, the local fire department or
similar government agencies, or your insurance agent
can help you determine code requirements.

Also refer to:

-- ANSI/NFPA 58, latest edition, Standard for

Storage and Handling of Liquefied Petroleum
Gas 

-- ANSI Z223.1/NFPA 54, National Fuel Gas Code
--  CAN/CSA B149.1 Natural Gas and Propane

Installation Code

3.

The heater shall not be directed toward any propane
gas container within 20 ft. (6 m).

4.

Disconnect the heater from its propane gas supply
container when relocating.

5.

Do not move the heater while it is in operation.

6.

We cannot anticipate every use which may be made of
our heater.  Check with your local fire safety authority
if you have questions about applications.

7.

Other standards govern the use of fuel gases and heat
producing products in specific applications.  Your local
authority can advise you about these.

8

Use only compressed air, a soft brush, or dry cloth to
clean the heater and it’s components. Allow the heater
to completely cool before cleaning or servicing.

9.

Always use approved pipe thread compound suitable
fo r   u s e   w i t h   p ro p a n e   g a s   o n   t h e   t h r e a d e d
connections.

10.

Do not block air intakes or discharge outlets of the
heater.  Doing so may cause improper combustion or
damage to heater components leading to property
damage.

11.

The hose assembly shall be visually inspected before
each use of the heater.  If it is evident there is
excessive abrasion or wear, or if the hose is cut, it
must be replaced prior to the heater being put into
operation.  The hose assembly shall be protected
building materials, and contact with hot surfaces
during use.  The hose assembly shall be that specified
by the manufacturer.  See parts list.

12.

Check for gas leaks and proper function upon heater
installation or when relocating.  Refer to leak check
instructions within installation section of this manual.

13.

This heater should be inspected for proper operation
by a qualified service person before each use and at
least annually.

14

Always turn off the gas supply to the heater if the
heater is not going to be used.

15.

If gas flow is interrupted and flame goes out, do not
relight the heater until you are sure that all gas that
may have accumulated has cleaned away.  In any
event, do not relight the heater for at least 5 minutes.

16.

Minimum propane gas supply cylinder size to be used
shall be 100 pounds (45 kg).  When using a cylinder
supply system, the system must be arranged to
provide vapor withdrawal from the operating cylinder.

17

W h e n   t h e   h e a te r   i s   to   b e   s to r e d   i n d o o r s ,   t h e
c o n n e c t i o n   b e t we e n   t h e   p ro p a n e   g a s   s u p p l y
cylinder(s) and the heater must be disconnected and
the cylinder(s) removed from the heater and stored in
accordance with the Standard and Handling of
Liquefied Petroleum Gases, ANSI/NFPA 58, or the
Natural Gas and Propane Installation Code, CAN/CSA
B149.1 as appropriate .

18.

Propane gas supply containers have left handed
threads.  Always use the appropriate wrench to tighten
or loosen the regulator’s P.O.L. fitting at the propane
gas container’s supply valve. 

6

WARNING

Burn Hazard

Radiant heaters are normally quiet during operation.

Always be aware of your proximity to the radiant
heater during its use.

D o   n ot   to u c h   t h e   h e a te r   o r   c o m e   w i t h i n   s a fe

clearances given on dataplate and Owner’s Manual.  

Failure to follow this warning can result in ignition of
clothing and burns, causing severe injury.

Содержание CR125AZPA220206

Страница 1: ...ruction Heaters View this manual online at www lbwhite com ATTENTION ALL USERS This heater has been tested and evaluated by ETL in accordance with Standard ANSI Z83 7 CSA 2 14 and is listed and approv...

Страница 2: ...property damage personal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury or b...

Страница 3: ...o Inc for assistance or if you have any questions about the use of the equipment or its application The L B White Co Inc has a policy of continuous product improvement It reserves the right to change...

Страница 4: ...5 1 52 SIDES 5 1 52 US 6 ft 1 83 CANADA 10 3 05 N A SPECIFICATIONS CR125 Propane Natural Gas Gas Model Dimensions Inches cm L x W x H Minimum Safe Distances From Nearest Combustible Materials Feet Me...

Страница 5: ...FR 1926 154 Temporary Heating Device ANSI A10 10 Safety Requirements for Temporary and Portable Space Heating Devices or the Natural Gas and Propane Installation Code CAN CSA B149 1 as appropriate Asp...

Страница 6: ...ocal authority can advise you about these 8 Use only compressed air a soft brush or dry cloth to clean the heater and it s components Allow the heater to completely cool before cleaning or servicing 9...

Страница 7: ...securely fastened to prevent ignition or upsetting of the heater due to wind action on the covering or other material 8 Check all connections for gas leaks using approved gas leak detectors Gas leak t...

Страница 8: ...u are in doubt contact the L B White Co Inc 13 Take time to understand how to operate and maintain the heater by using this Owner s Manual Make sure you know how to shut off the gas supply to the heat...

Страница 9: ...dle while the heater is operating or after the heater has been shut down can result in burns causing injury HANDLE WHEELS Assemble the wheels the the base of the heater as shown in Fig 5 Tighten secur...

Страница 10: ...7 4 Keep the knob depressed for about 30 seconds to allow the thermocouple to warm up On new installations it may take a short time for gas to purge out any air before the burner lights 5 Release the...

Страница 11: ...re the gas hose does not have any nicks or cuts and its connections are not corroded or have stripped threads Replace the gas hose assembly if necessary Do not repair Before each use give the heater a...

Страница 12: ...lean the heater s burner and pilot orifices with compressed air or a soft dry rag Do not use files drills etc which may enlarge the holes causing combustion ignition problems Replace the component if...

Страница 13: ...allowing the thermocouple to heat up for an extended period of time Normal time for thermocouple warm up is 30 seconds to 1 minute To determine if the thermocouple is defective Connect tip switch lead...

Страница 14: ...e electrode check the following areas A Igniter 1 Remove the wire from the push button igniter 2 Position a screwdriver tip about 1 8 in 3 mm from igniter See Fig 14 3 Holding the screwdriver by its h...

Страница 15: ...s manual 2 Does the pressure reading agree with that given on the dataplate If so no further checking or adjustment is required Proceed to section D 3 If the pressures does not agree with that specif...

Страница 16: ...released Insufficient time allowed for pilot Hold in pilot button for 30 seconds to allow proper light to heat up thermocouple warm up Loose thermocouple Tighten thermocouple at gas control and make...

Страница 17: ...thermocouple REGULATOR The heart of any gas supply installation Used to deliver a working pressure to the appliance under varying conditions in tank pressure SAFETY CONTROL VALVE A gas control valve w...

Страница 18: ...18 Parts Identification Parts Schematic...

Страница 19: ...er orifice LP gas 573281 Natural gas 573282 10 Pilot orifice LP gas 573266 Natural gas 573269 11 Thermocouple 573267 12 Pilot assembly LP gas 573268 Natural gas 573322 13 Mounting plate 573301 14 Elec...

Страница 20: ...nths of the date code marked on the part If the defect occurs more than 24 months later than the date code but within 24 months from the date of purchase by the end user a copy of a bill of sale will...

Страница 21: ...abrication de ses appareils de chauffage L B White tient vous remercier de la confiance que vous lui t moignez et vous invite lui communiquer tout commentaire ou suggestion sans frais au 1 800 345 720...

Страница 22: ......

Страница 23: ...s rieuses ou la mort MISE EN GARDE G N RALE Le non respect des mesures de pr cautions ainsi que des directives d utilisation de cet appareil telles que d crites dans ce manuel peut entrainer La mort...

Страница 24: ...de l appareil ainsi que son num ro de s rie Vous trouverez cette information sur la fiche signal tique de l appareil Ce manuel vous renseigne sur la fa on appropri e d utiliser et de maintenir votre a...

Страница 25: ...nimales de d gagement des mati res combustibles environnantes M tres Consommation de combustible l heure Combustible Pression au manifold du br leur kPa Sp cifications SPECIFICATIONS CR125 Gaz Gaz Pro...

Страница 26: ...ce de gaz chapp S assurer que ceux ci a rent convenablement l immeuble avant d y retourner S assurer que la fuite est colmat e et r par e par du personnel qualifi Bien s assurer que la fuite a bel et...

Страница 27: ...ns particuli res 7 Il existe d autres normes et codes qui r gissent l utilisation d appareils au gaz dans certaines circonstances et applications particuli res S en informer aupr s des autorit s de vo...

Страница 28: ...lorsqu il est chaud ou en op ration en plus d tre une distance s curitaire de mat riaux combustibles tels que murs planchers ou plafonds Ne pas placer d objets pouvant devenir combustibles l int rieur...

Страница 29: ...les fuites ont t identifi es et colmat es avant de continuer d op rer l appareil 9 Une v rification de la pression du gaz doit tre effectu e par le repr sentant d une autorit comp tente en la mati re...

Страница 30: ...venir tout dommage et d emp cher que des salet s ne p n trent dans le r gulateur R gulateur de gaz naturel Pression d entr e maximale 3 36 kPa Pression d entr e minimale 1 74 kPa Brancher le r gulate...

Страница 31: ...se de la poign e pendant que l appareil de chauffage fonctionne ou apr s son arr t peut entra ner des br lures POIGN E ROULETTES Monter les roues pour le chauffage comme illustr la figure 5 Bien serre...

Страница 32: ...leuse Consulter la figure 8 FIG 7 4 Maintenir la pression sur le bouton environ 30 secondes pour permettre le r chauffement du thermocouple Il faut noter que sur des installations r centes il peut s c...

Страница 33: ...le radiateur doivent tre d gag s et libres de toute mati re combustible d essence et d autres vapeurs et liquides inflammables 2 Le r gulateur doit tre inspect de temps autre afin d assurer que l vent...

Страница 34: ...nne bien V rifier s il y a pr sence de fuites de gaz 5 Nettoyer le l orifice de l appareil de chauffage avec de l air comprim ou un chiffon doux et sec Ne pas utiliser de lime de perceuse ou autre pou...

Страница 35: ...as fait la veilleuse pourrait s teindre Lors de la connexion du thermocouple la valve de contr le visser celui ci d abord la main puis une fois bien en place avec une cl molette FIG 13 BARILLET D ORIF...

Страница 36: ...Retirer le fil reli au bouton poussoir de l allumeur 2 Placer la pointe d un tournevis une distance d environ 3 mm po de l allumeur Consulter la figure 14 3 En tenant le tournevis par sa poign e appu...

Страница 37: ...pression coincident elles avec la fiche signal tique Si oui aucune autre v rification ou ajustements ne sont n cessaires Veuillez vous rendre directement la section D 3 Si les lectures de pression ne...

Страница 38: ...nir la pression sur lebouton poussoir de contr le rel ch e r chauffer ad quatement le pendant 30 secondes pour permettre un r chauffement thermocouple appropri Thermocouple desserr Serrer ad quatement...

Страница 39: ...ermocouple Fonctionne directement et simultan ment avec le thermocouple R GULATEUR La pi ce ma tresse de tout syst me aliment au gaz Utilis pour fournir une pression de gaz appropri e l appareil sous...

Страница 40: ...19 Sch ma des pi ces composantes Identification des pi ces composantes...

Страница 41: ...Propane 573281 Gaz naturel 573282 10 Orifice de la veilleuse Propane 573266 Gaz naturel 573269 11 Thermocouple 573267 12 Assemblage de la veilleuse Propane 573268 Gaz naturel 573322 13 Plaque de fixat...

Страница 42: ...s av rait d fectueuse l int rieur d une p riode de 24 mois d butant la date code inscrite sur ladite pi ce Si la d fectuosit survient plus de 24 mois apr s la date code mais n anmoins l int rieur d un...

Отзывы: