background image

1. Please read all material provided with this product including the owner's manual and instructions

and the safety instructions and information before installing, operating, maintaining or repairing
this heater.  If either of these manuals are missing or misplaced or you have any questions, contact
your dealer or the L. B. White Co., Inc. (608-783-5691).  Do not perform maintenance on this product
without referring to the instruction manual.

2. It is your responsibility to ensure the application and installation of this product meet the requirements

of all local, regional and national L.P. gas or natural gas, electrical and safety codes.

3. If at any time you notice something unusual about the operation of this product such as gas odor,

overheating, flames other than in the normal area, etc. 

immediately turn off the gas at the L.P. tank or

main supply, evacuate the area, and call your fire department and your L.P. or natural gas service
person.  Get assurances from the fire department that the area is free of gas before resuming
operation.  (L.P. gas is heavier than air and can settle in low areas.)

4.

Repair work should be done by a qualified service person only! 

The operator should inspect the

product before each use.  In addition, an annual inspection by a qualified service person is

recommended.

5. Product must be used in accordance with minimum clearances listed in owner's manual and on unit

nameplate.  Also, do not use this product in an area where there are combustible contaminates in the air.

6. Do not operate this product in a tightly closed room.  Combustion of any fuel requires adequate oxygen.

Adequate ventilation is required as listed in the owner’s manual and on the unit nameplate.

7. This product is not recommended for heating human living quarters.

8. Save all the information included with this product for your installing or servicing dealers and your

own future reference.

Place

Stamp

Here

Name _______________________
Address _____________________
City ________________________
State __________ Zip ________

L. B. White Co., Inc.

W6636 L.B. White Road
Onalaska, WI    54650

IMPORTANT!

IMPORTANT!

For Your Safety, Observe the Following Precautions.

Содержание CP125AK

Страница 1: ...tructions Tradesman Kerosene Heaters ATTENTION ALL USERS This heater has been tested and evaluated by C S A International in accordance with the requirements of Standard UL 733 and ANSI A10 10 1990 CA...

Страница 2: ......

Страница 3: ...rborne combustibles include gasoline solvents paint thinner dust particles or unknown chemicals Failure to follow these instructions may result in a fire or explosion Fire or explosions can lead to pr...

Страница 4: ...formation 24 Table of Contents General Information This Owner s Manual includes all options and accessories commonly used on this heater When calling for technical service assistance or for other spec...

Страница 5: ...ne 125 000 170 000 210 000 520 CFM 600 CFM 650 CFM 5 5 6 5 8 5 95 1 3 1 6 Ball Bearing 1 5HP 3455 RPM 1 4HP 3430 RPM 1 3HP 3380 RPM 120 60 1 2 5 3 2 3 7 43 1 2 x 23 29 32 x 26 19 32 4 ft 4 ft 4 ft 8 f...

Страница 6: ...result in minor or moderate injury WARNING Before using this heater please read this USER S MANUAL very carefully This USER S MANUAL has been designed to instruct you as to the proper manner in which...

Страница 7: ...locate heater on a stable and level surface Use 1 K kerosene in this heater 1 fuel oil is a suitable substitute Bulk fuel storage should be a minimum of 25 ft from heaters torches portable generators...

Страница 8: ...ed promptly inform dealer where you purchased heater Dimensions Figure 1 Heater Dimensions Product Features CP125AK CP170AK CP210AK Height 24 29 32 26 19 32 Length 37 1 2 43 1 2 Width 22 13 32 23 29 3...

Страница 9: ...nose pliers to secure 3 Place wheel cap on flat washers and put wheel cap in flat washers end 4 Place heater on wheel support frame Make sure the air inlet end rear of heater is over wheels Align the...

Страница 10: ...esigned to turn the heater off should the internal temperature rise to an unsafe level If this device activates and turns your heater off it may require service Once the temperature falls below the re...

Страница 11: ...es in figure When room temp is greater than 99o F Hi If heater does not start the thermostat setting may be too low Turn THERMOSTAT CONTROL KNOB to higher position to start heater If heater still does...

Страница 12: ...rain plug as follows Insert plug s seal head fully into drain hole so that flange is flush to tank s bottom See Figure 9 Insert seal cap fully into head hole so that cap flange is flush to head flange...

Страница 13: ...S CLEAN EVERY SEASON OR AS NEEDED Remove upper shell See Air Intake Filter Use M6 Allen wrench to loosen set screw which holds fan blade to motor shaft Slip fan blade off motor shaft Clean fan blade u...

Страница 14: ...line hoses from adapter nozzle Remove ignitor wire from spark plug Remove four screws using medium Phillips screwdriver and remove bracket burner from combustion chamber Remove spark plug from bracke...

Страница 15: ...egap spark plug electrodes to 140 3 5 mm gap Reinstall spark plug into bracket spark Attach ignitor wire to spark plug Reinstall fan and upper shell F Figure 15 Spark Plug Replacement Spark Plug Ignit...

Страница 16: ...h Wires Power Switch Side Cover Screw PUMP PRESSURE ADJUSTMENT Start heater See Operation page 10 Allow motor to reach full speed Adjust pressure using flat blade screwdriver Turn relief valve clockwi...

Страница 17: ...medium Phillips screwdriver Disconnect switch wires from power switch Remove fuse from fuse holder See Figure 16 Replace fuse with enclosed fuse Replace switch wires to power switch Replace side cove...

Страница 18: ...4 17 WIRING DIAGRAM Figure 21 Wiring Diagram Models CP125AK CP170AK CP210AK CP125AK CP170AK CP210AK...

Страница 19: ...between motor and MAIN PCB Assembly 1 Room Temp sensor disconnected 2 Sensor Failure Thermostat switch failure 1 Temperature limit safety device is overheated 2 No electrical power 3 Blown fuse 4 Bad...

Страница 20: ...n and number as shown in parts list PARTS SCHEMATIC CP125AK CP170AK Parts Identification Figure 22 Repair Parts Illustration for Portable Oil Fired Heaters Models CP125AK CP170AK 1 7 2 11 3 8 6 22 23...

Страница 21: ...572278 15 4 Spark Plug Assembly 572201 16 Fan Guard 572266 17 Fan Assembly 572234 572235 18 Motor and Pump Assembly 572205 572206 18 1 Motor 572209 572210 18 2 Capacitor 572215 18 3 Motor Support 572...

Страница 22: ...ease provide following information Model number Serial number if any Part description and number as shown in parts list PARTS SCHEMATIC CP210AK Parts Identification 16 1 16 2 16 3 16 5 16 4 7 5 2 6 11...

Страница 23: ...bly 572202 17 Fan Assembly 572235 18 Motor and Pump Assembly 572207 18 1 Motor 572211 18 2 Motor Support 572220 18 3 Capacitor Holder 572249 18 4 Capacitor 572215 18 5 Pump Body 572224 18 6 Rotor Kit...

Страница 24: ...5 5 Hardware Kit 572271 Ref Part No for Models No Description CP125AK CP170AK CP210AK Replacement Parts List for Models CP125AK CP170AK CP210AK For Repair Parts call 1 800 345 7200 Please provide foll...

Страница 25: ...y the end user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months later than the date code but within...

Страница 26: ...ns Appareil de chauffage portatif pulsion d air Tradesman Certifi par ATTENTION TOUS LES UTILISATEURS Cet appareil a t test et valu par le C S A International selon les normes en vigueur UL 733 et ANS...

Страница 27: ......

Страница 28: ...substances chimiques d origine inconnue sont autant de substances volatiles ou de combustibles en suspension Le non respect de ces consignes peut entrainer un incendie ou une explosion Un incendie ou...

Страница 29: ...t options couramment utilis s avec cet appareil Toutefois selon la configuration exacte de l appareil acquis il se peut qu une ou plusieurs options ou accessoires ne soient pas inclus Lorsque vous dev...

Страница 30: ...9 m3h 1019 40 m3h 1104 36 m3h 39 9 44 8 58 6 3 60 4 92 4 92 Roulement a billes 170 WATT 3455 RPM 200 WATT3430 RPM 245 W ATT 3380 RPM 120 60 1 2 5 3 2 3 7 1104 9 x 607 2 x 675 5 125 cm 125 cm 125 cm 25...

Страница 31: ...Ne jamais laisser le radiateur sans surveillance s il fonctionne DANGER L utilisation inappropri e de ce radiateur peut causer des blessures graves ou mortelles suite des br lures un incendie une exp...

Страница 32: ...carbone Elles comprennent les femmes enceintes les personnes souffrant des probl mes de c ur ou de poumons d an mie sous l influence de l alcool ou des altitudes lev es S assurer que l alimentation le...

Страница 33: ...vendu Figure 1 Dimensions du radiatuer Caract ristiques CP125AK CP170AK CP210AK H 636 6 mm 675 5 mm L 952 5 mm 1104 9 mm Lar 569 1 mm 607 9 mm Figure 2 Caract ristiques Sortie d air chaud Enveloppe i...

Страница 34: ...ins r chaque vis 5 Lorsque toutes les vis sont ins r es serrer fermement tous les crous 6 Aligner le trou de la poign e avant et arri re sur le trou de montage du dispositif d enroulement du cordon 7...

Страница 35: ...spositif est activ et qu il teint le radiateur ce dernier pourrait exiger une r paration Lorsque la temp rature baisse en de du seuil de r initialisation il sera possible de d marrer le radiateur Prot...

Страница 36: ...e la temp rature ambiante est inf rieure 37 C 99 F Hi haute Si le radiateur ne d marre pas le r glage du thermostat est peut tre trop bas Tourner le BOUTON DE COMMANDE DE THERMOSTAT uneposition plus l...

Страница 37: ...ement la t te du joint du bouchon dans le trou de vidange pour que la collerette soit de nivoiru avec le fond du r servoir Voir la Figure 9 Ins rer le bouchon d tanch it compl tement dans le trou pour...

Страница 38: ...uvercle du filtre d extr mit Remplacer le filtre de sortie d air et charpie Remettre en place le couvercle du filtre air et le manom tre R installer la protection de ventilateur et l enveloppe sup rie...

Страница 39: ...ventilateur Enlever les tuyaux de combustible et de la conduite d air de l adaptateur de buse Enlever le fil de l allumeur de la bougie d allumage Enlever les quatre vis l aide d un tournevis Phillip...

Страница 40: ...R installer le ventilateur et l enveloppe sup rieure CELLULE PHOTO LECTRIQUE NETTOYER LA CELLULE PHOTO LECTRIQUE TOUS LES ANS OU SELON LE BESOIN Enlever l enveloppe sup rieure voir Filtre d entr e d a...

Страница 41: ...R gler la pression utiliser un tournevis lame plate Tourner la soupape de s ret dans le sens horaire pour augmenter la pression Tourner la soupape de s ret dans le sens antihoraire pour diminuer la pr...

Страница 42: ...ncher les fils de l interrupteur d alimentation Enlever le fusible du porte fusible voir la Figure 20 Remplacer le fusible par un fusible enferm Rebrancher les fils de l interrupteur d alimentation Re...

Страница 43: ...DE LA COMMANDE NOIR NOIR CELLULE PHOTO LECTRIQUE BLANC NOIR BLANC NOIR TERRE VERT C A 120 V 60 Hz NOIR INTERRUPTEUR D ALIMENTATION COMMANDE DE LIMITEUR FUSIBLE 8 A 125V c a NOIR MOTEUR DE POMPE NOIR...

Страница 44: ...l interrupteur du thermostat 1 Le dispositif de s curit de temp rature limite a surchauff 2 Pas d alimentation lectrique 3 Fusible br l 4 Mauvaise connexion lectrique entre le dispositif de s curit de...

Страница 45: ...24 19 4 12 25 16 10 21 20 18 17 15 14 15 1 15 2 15 3 15 4 13 5 9 26 4 19 Sch ma de Parties CP125AK CP170AK Identification de Parties Commandez les pi ces d tach es en appelant gratuitement 1 800 345...

Страница 46: ...tion de ventilateur 572266 17 Ventilateur 572234 572235 18 Moteur et pompe 572205 572206 18 1 Moteur 572209 572210 18 2 Condensateur 572215 18 3 Support de moteur 572219 18 4 Bande condenseur 572248 1...

Страница 47: ...7 18 20 1 3 6 9 18 3 18 1 18 2 18 10 18 9 18 8 18 7 18 6 18 5 18 4 19 4 9 4 21 Sch ma de Parties CP210AK Identification de Parties Commandez les pi ces d tach es en appelant gratuitement 1 800 345 720...

Страница 48: ...Moteur et pompe 572207 18 1 Moteur 572211 18 2 Support de moteur 572220 18 3 Support de condensateur 572249 18 4 Condensateur 572215 18 5 Corps de la pompe 572224 18 6 Kit de rotor 572226 18 7 Couverc...

Страница 49: ...rousse de visserie 572271 Ref Part No for Models No Description CP125AK CP170AK CP210AK Liste de parties CP125AK CP170AK CP210AK 1 5 3 4 2 HARDWARE KIT 4 23 Le sch ma de partie manipule et les roues I...

Страница 50: ...de de douze 12 mois calcul e partir de l achat de la pi ce par l utilisateur final La garantie s applique automatiquement si une pi ce s av rait d fectueuse l int rieur d une p riode de 12 mois d buta...

Страница 51: ...allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have o...

Страница 52: ...tment that the area is free of gas before resuming operation L P gas is heavier than air and can settle in low areas 4 Repair work should be done by a qualified service person only The operator should...