LA8
AMPLIFIED CONTROLLER
MAINTENANCE MANUAL – LEVEL 1
VERSION 2.0
LA8_MM1_EN_2.0
w w w . l - a c o u s t i c s . c o m
1 8 / 21
D/R 003 – Power plug
Tools
Name
Reference
Distributor
wire stripping pliers
793936
Facom
Stanley knife
0-10-018
Stanley
screwdriver adapted to the new power plug
—
—
voltage absence tester
—
—
Spare parts
N
o
Description
Qty
1
power plug
1
Safety
There is a risk of electrical injury when the high-voltage capacitors are charged.
Before any maintenance operation, disconnect the controller from mains and wait for
10 minutes
so the
capacitors discharge completely.
Check that there is no voltage at the two pins of the power plug.
Replacement procedure
This procedure describes how to replace the power plug of an LA8 amplified controller.
Unplug the POWER CORD from the mains and wait for
10 minutes
.
1.
Check that there is no voltage at the two pins of the power plug.
2.
Use the voltage absence tester.
Cut the POWER CORD near the plug.
3.
Use the Stanley knife.
Strip the three wires of the power cord on a length compatible with the new plug.
4.
Use the Stanley knife and the wire stripping pliers.
Fix the three wires on the new plug according to the color code of Table 1.
5.
Use the screwdriver.
Table 1: Wire color code
Controller
Live
Neutral
Ground
LA8
Brown
Blue
Green / Yellow
LA8CN
LA8JP
LA8US
Black
White
Green