External structure
Issue
Possible causes
Inspection procedure / Diagnosis
FOAM FILTER clogged
operation in very dusty or
cracked-oil smoke machine
environments
Clean the FOAM FILTER, see procedure
D/R 002
.
Inside of the controller dirty
(visible from the front grill)
operation in very dusty or
cracked-oil smoke machine
environments
Contact L-ACOUSTICS
®
.
FOAM FILTER lost or damaged
mechanical shock
Replace the FOAM FILTER, see procedure
D/R 002
.
FRONT FRAME lost or damaged
mechanical shock
Replace the FRONT FRAME, see procedure
D/R 001
.
REAR BRACKETS lost or damaged
mechanical shock
Replace the REAR BRACKETS, see
procedure
D/R 004
.
CHASSIS damaged
mechanical shock
Contact L-ACOUSTICS
®
.
POWER CORD damaged
pulled, trampled, pinched,
frayed…
Contact L-ACOUSTICS
®
.
Power plug of wrong model
reference does not exist
Replace the power plug, see procedure
D/R 003
.
CA-COM
®
or SpeakON
®
connector damaged
mechanical or electrical shock
Contact L-ACOUSTICS
®
.
XLR connector damaged
mechanical shock
Contact L-ACOUSTICS
®
.
L-NET connector damaged
mechanical shock
Contact L-ACOUSTICS
®
.
LCD screen, encoder wheel, key,
or LED meter damaged on the
DISPLAY
mechanical shock
Contact L-ACOUSTICS
®
.