LA8
AMPLIFIED CONTROLLER
MAINTENANCE MANUAL – LEVEL 1
VERSION 2.0
LA8_MM1_EN_2.0
w w w . l - a c o u s t i c s . c o m
1 0 / 21
Error message
Issue
Possible causes
Inspection procedure / Diagnosis
“High Temperature Ch
x
Channel Attenuated”
“Over Temperature Ch
x
Channel Muted”
room temperature too
1.
high
Reduce the temperature using a forced
ventilation system.
FOAM FILTER clogged
2.
Clean the FOAM FILTER, see procedure
D/R 002
.
controller not getting
3.
enough cool air
Install the controller in an open area so
that the front and rear panels are located
at a minimum distance of 30 cm from any
external object or structure.
Do not block the front and rear
ventilation grills on a controller.
If the controller is rack-mounted:
Do not block the ventilation grills with
front or back panels or doors. If not
possible, use a forced ventilation
system.
When stacking more than one
controller in a rack, mount them
directly on top of each other or close
any open space in the rack with blank
panels.
channel
x
resources
4.
solicited to their limits
Monitor the LED meter for channel
x
on
the controller.
In case of persistent high level or clip,
reduce the audio source output level (refer
to the
third party documentation
) and/or
the gain value on channel
x
.
loudspeaker impedance
5.
too low
Verify that nothing causes a short-circuit at
output
x
(wrong cabling scheme, damaged
cable, or short-circuit in the speaker voice
coil).
Verify that the number of enclosures
connected in parallel to output
x
is not too
high.
other cause
6.
Contact L-ACOUSTICS
®
.
continued on next page…