88
Leveling
For correct operation, the refrigerator MUST be within three
degrees of level in any direction. Continued operation outside of
these limits will result in irreparable damage to the cooling unit in the
refrigerator.
Venting
For an absorption unit to operate fully it MUST have two vents. The
lower vent serves as access to service components and allows air to
enter. As the refrigerator heats up, warm air leaves through the
upper vent in the roof or the side vent. The roof vent gives the best
“chimney” results. With correct baffles, side vent will work. All
vents MUST prevent birds and rodents from entering.
Units with two-side vents as in slide-outs, require a 12V fan to be in
operation. When upper cooling fins reach 150° Fahrenheit, the fan
will automatically start to operate. The positive wire has a
five amp
in line fuse installed. Access to the fuse is inside of the lower
service vent door.
Whenever your recreational vehicle is stored and not in use BE
SURE to turn switch to the “OFF” position avoiding 12-volt DC
If the user of this appliance fails to maintain it in the condition in which it
was shipped from the factory or if the appliance is not used solely for its
intended purpose or if the appliance is not maintained in accordance with
the instructions in this manual then the risk of a fire and/or the production
of carbon monoxide exists which can cause personal injury, property dam-
age or loss of life.
DANGER
!
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
DANGER
!
PDF created with pdfFactory trial version
Содержание SPORTSMEN
Страница 17: ...10 PDF created with pdfFactory trial version www pdffactory com...
Страница 18: ...11 PDF created with pdfFactory trial version www pdffactory com...
Страница 19: ...12 PDF created with pdfFactory trial version www pdffactory com...
Страница 101: ...94 Important Phone Numbers PDF created with pdfFactory trial version www pdffactory com...