34
not clear signals, check the battery voltage.
If the battery voltage is
not low and the unit will not return to normal operation,
immediately remove the alarm and return for service or
warranty replacement.
OPERATION AUDIBLE SIGNAL VISUAL SIGNAL
NORMAL NONE STEADY GREEN
CO ALARM 4”BEEPS” STEADY RED
5 SECONDS OFF
PROPANE ALARM CONSTANT FLASHING RED
ALARM “BEEP” EVERY ALTERNATING
MALFUNCTION 30 SECONDS RED/GREEN
END OF LIFE BEEP EVERY RED/RED
30 SECONDS GREEN/GREEN
FLASHING
End of Life Signal—5 year Service Life
All 35 series models include an End of Life (EOL) Signal indicating
the sensor has reached he end of it’s service life and you MUST
replace the alarm. The signal is the LED flashing RED RED GREEN
GREEN with a beep every 25-30 seconds. The EOL Signal may be
reset by pushing TEST/RESET button on the alarm. This will reset
the EOL Signal for a period of 72 hours (3 days) for a total of up to
30 days. After 30 days the signal cannot be reset and the alarm
MUST be replaced. DO NOT DISCONNECT THE ALARM UNTIL
YOU HAVE A REPLACEMENT ALARM AVAILABLE TO INSTALL.
LIMITATIONS OF CO AND GAS ALARMS
THIS ALARM WILL NOT WORK WITHOUT POWER
Some reasons for no alarm power are; a blown or missing fuse; broken
wire; a faulty wire connection or circuit breaker; a discharged battery; cut
lead wires, or improper supply (+) or ground (-) connections.
WARNING!
!
PDF created with pdfFactory trial version
Содержание SPORTSMEN
Страница 17: ...10 PDF created with pdfFactory trial version www pdffactory com...
Страница 18: ...11 PDF created with pdfFactory trial version www pdffactory com...
Страница 19: ...12 PDF created with pdfFactory trial version www pdffactory com...
Страница 101: ...94 Important Phone Numbers PDF created with pdfFactory trial version www pdffactory com...