7
̶
OUTPUT Voltage (Output impedance: about 10k
Ω
)
Range
DC Output Voltages Input Currents
Accuracy
DC
400A
0 to 400.0mV 0 to 400A
±
1.5%rdg
±
3mV
2000A 0 to 200.0mV 0 to 2000A
±
1.5%rdg
±
3mV
AC
400A
0 to 400.0mV 0 to 400A
±
1.5%rdg
±
3mV(50/60Hz)
±
3.0%rdg
±
3mV(40
〜
500Hz)
±
5.0%rdg
±
3mV(500
〜
1kHz)
2000A
0 to 100.0mV 0 to 1000A
100.1 to 200.0mV 1001 to 2000A
±
3.0%rdg
±
3mV(50/60Hz)
*Electromagnetic compatibility (EN 61000-4-3)
:RF field strength = <= 1V/ m, total accuracy = specified accuracy
:RF field strength =3V/m, total accuracy = specified ac1% of range
⃝
Operating System
: Dual Integration
⃝
Display
: Liquid crystal display with maximum
counts of 4000
⃝
Low Battery Warning : "BAIT" symbol is displayed on the digital
display.
⃝
Overrange Indication : On each range, when the measured value
exceeds the measuring range, "OL" mark
appears on the LCD.
⃝
Response Time
: Approx. 2 seconds
⃝
Sample rate
: Approx. 2.5 times per second
⃝
Location for use
: Indoor / Outdoor use, Altitude up to 2000m
⃝
Temperature and Humidity for Guaranteed Accuracy
: 23
℃±
5, relative humidity up to 85%
without condensation
⃝
Operating Temperature and Humidity
: 0 to 40
℃
, relative humidity up to 85%
without condensation
⃝
Storage Temperature and Humidity
: -20 to 60
℃
, relative humidity up to 90%
without condensation
Содержание KEW 2003A
Страница 1: ...INSTRUCTION MANUAL KEW SNAP SERIES KEW 2003A DIGITAL CLAMP METER...
Страница 30: ...28 MEMO...
Страница 31: ...29 MEMO...