After Use

 1. Turn the main switch to the OFF position.

 2. Turn the water faucet off.

 3. Depress the spray handle trigger until all water has 

stopped flowing from the nozzle.

 4. Pull the hose joint coupler forward to release the water 

supply hose from the water connector. 

 5. Depress the spray handle safety lock button to lock the 

trigger.

 6. Remove the spray handle hose from the main unit.

 

7. Remove remaining water from the main unit

   Turn the main switch to the ON position for 1-2 seconds 

to discharge excess water from the spray handle hose 

connection port.

  

WARNING!

 Exercise caution as the released of excess 

water is highly pressurized

  

WARNING!

 Leaving the main switch on for longer than 2 

seconds may damage the unit. Be sure to turn the main 

switch off immediately.

 8. Unplug the power cord.

 9. Remove the water supply hose from the faucet.

 

10. Press the release button (18) to remove the spray 

handle hose (5) from the spray handle (4). (Fig. 13)

WARNING!

Remove all excess water from the main unit, spray handle 

hose, spray handle and nozzles especially in cold weather. 

Storing the unit in cold temperatures without removing all 

excess water may damage the unit and cause malfunction.

Maintenance and storage 

WARNING! Always disconnect the plug form the socket prior 

to maintenance or cleaning.

To ensure a long and problem free working life, please take 

the following advice:

• Wash off water hose, spray handle hose, spray lance and 

accessories before mounting.

• Clean the connectors of dust and sand.

Any repair should always be made by our authorized 

distributor with genuine spare parts.

Nozzle Cleaning and Maintenance (Fig.14)

• Use the nozzle cleaning pin (8) to regularly clean inside 

the nozzle.

• Insert the nozzle cleaning pin (8) into the nozzle and 

remove any foreign matter lodged in the nozzle by tapping 

the nozzle onto a desk or table with the nozzle opening 

pointed downward.

  If the nozzle is clogged, low spray pressure and/or 

malfunction of the pressure switch may result. 

WARNING!

 Confirm that the nozzle is free of debris by 

removing it from the spray handle and visually inspecting 

inside the opening. Always clean the nozzle opening after 

removing it from the spray handle.

Cleaning the Filter (Fig.15)

 1. Loosen the water connector (6) and remove it from the 

unit.

 2. Remove the filter (16) in the water connector (6).

 3. Rinse away any accumulated debris from the filter's 

mesh.

 4. Return the filter to its original position.

 5. Reconnect the water connector to the unit.

   Ensure that the water connector is threaded straight 

onto the water connection port before gently rotating it 

in a clockwise direction. (If the connector is not threaded 

correctly onto the port, leaking may occur.)

Cleaning of machine vents

The machine should be kept clean so as to let cooling air 

pass freely through air vents.

Storing the Unit

• The hoses, nozzles, and spray handle may be stored on 

the main unit as shown in Figure 16.

Storage 

Pump, hose and accessories should always be emptied of 

water prior to storing as follows:

 1. Long periods of nonuse: If the machine is going to be 

stored for longer periods of time (i.e. over three months) 

in a room where frost could develop, it is recommended 

that the machine be filled with an antifreeze solution 

(similar to the antifreeze solutions used for vehicles).

 2. When the device is not used for an extended period of 

time, lime deposits begin to form in the motor pump, 

which in turn can lead to starting difficulties.

NEVER START UP A FROZEN MACHINE.

Frost damages are not covered by the guarantee!

Environmental protection

Recycle unwanted materials instead of disposing 

of them as waste. All tools, hoses and packaging 

should be sorted, taken to the local recycling centre 

and disposed of in an environmentally safe way.

WARNING: Do not use appliance without reading 

the instruction sheet

Machine not suitable for connection to the potable 

water mains

To reduce the risk of injury, user must keep all 

bystanders at least 15m away.

High pressure jets can be dangerous if subject to 

misuse. The jet must not be directed at persons, 

live electrical equipment or the machine itself.

Содержание RYOBI AJP-800

Страница 1: ...69800384 00 KAP 04 20 AJP 800...

Страница 2: ...1 1 1 2 7 8 3 4 5 6 2 3 4 4 5 6 5 11 10 17 9 5 2 3 4 6...

Страница 3: ...2 A B B A 7 10 14 2 13 4 5 18 8 6 16 17 10 7 6 12 15 4 5 2 3 9 3 4 7 8 9 11 10 12 15 14 13 16...

Страница 4: ...ay Damaged parts must be immediately replaced by a qualified electrician Always pull the power plug out of the socket outlet before doing any work on the machine before changing the nozzle and wheneve...

Страница 5: ...ere there could be a danger of explosion If any doubt arises please contact our authorized distributor It is not allowed to clean asbestos containing surfaces with high pressure This machine must not...

Страница 6: ...sed flow The wide spray setting is useful for removing dirt from large areas washing cars etc Attaching the Foam Nozzle Fig 12 1 Fill the foam nozzle container with manufacturer recommended detergent...

Страница 7: ...pressure switch may result WARNING Confirm that the nozzle is free of debris by removing it from the spray handle and visually inspecting inside the opening Always clean the nozzle opening after remo...

Страница 8: ...seals are worn The filter is clogged Change the nozzle Check clean exchange Check and or exchange Check and or exchange Check and or clean There is excess noise Air is being drawn in The valves are w...

Страница 9: ...t saat ini RCD Level Keamanan Produk IPX5 P e r a t u r a n K e s e l a m a t a n U m u m d a n Pencegahan Kecelakaan Ini Penting bahwa Anda membaca peraturan keselamatan dan instruksi pengoperasian s...

Страница 10: ...dengan tekanan tinggi Mesin ini tidak boleh digunakan pada suhu dibawah 0 C Sambungan pasokan listrik misalnya koneksi kabel RCD atau memperbaiki dilakukan dengan kualifikasi dan mematuhi IEC60364 1 i...

Страница 11: ...r yang disemprot menyebar berfungsi untuk menghilangkan kotoran di area yang luas mencuci mobil dll Pemasangan Deterjen Nozzle Gbr 12 1 Isi wadah nozzle sabun dengan sabun pencuci yang di rekomendasik...

Страница 12: ...n dengan mengetuknya pada meja dan ujung noselnya ke bawah Jika nosel tersumbat tekanan air akan rendah dan mungkin akan menyebabkan kerusakan pada alat PERINGATAN pastikan bahwa nosel selalu dalam ke...

Страница 13: ...tersumbat Katup seal aus Seal aus Filter tersumbat Gantikan nosel Cek bersihkan ganti Cek dan atau ganti Cek dan ganti Cek dan bersihkan Terlalu bising Angin tertarik ke dalam Katup aus kotor atau te...

Страница 14: ...13...

Страница 15: ...14...

Страница 16: ......

Отзывы: