background image

3

Preparation

Before starting up your machine, we advise you to carefully 

read through this instruction manual. Follow all instructions 

to minimize the risk of injuries when using the machine.

Prior to operation

Before starting up your machine, please check it carefully for 

any defects. If you find any, do not start up your machine and 

contact your distributor.

Especially check:

The insulation of the electric cable should be faultless and 

without any cracks. If the electric cable is damaged, it should 

be replaced by our authorized distributor.

Mains power supply connection

The following should be observed when connecting the 

machine to the electric installation:

• Check before operation that the local power supply is the 

same as the specifications on the rating label.

•  This machine is equipped with universal motor with double 

insulation. It is not necessary to have earth connection.  

• The electric installation shall be made by a certified 

electrician.

•  It is strongly recommended that the power supply to the 

machine should include a residual current device (RCD).

•  Product protection degree:IPX5

General safety regulations and accident 

prevention

It is essential that you read the safety regulations and 

operating instructions in their entirety and follow the 

information contained therein in order to eliminate the 

possibility of an accident or potentially dangerous situation 

from occurring while working with the machine.

• The power plug must be plugged into a properly installed 

socket. The power supply should include a residual 

current device for max. 30 mA.

• Always check the device, the mains cable and the plug 

before using the machine. Only operate the device when 

it is in good working order and has not been damaged in 

any way. Damaged parts must be immediately replaced 

by a qualified electrician.

•  Always pull the power plug out of the socket outlet before 

doing any work on the machine, before changing the 

nozzle and whenever it is not being used.

•  Warning! Inadequate extension cords can be dangerous.

•  If an extension cord is used, it shall be suitable for outdoor 

use, and the connection has to be kept dry. 

•  Only use suitable extension cable when working outdoors. 

Extension cable must have a minimum cross-section of 

1.5 mm

2

• Warning! This device was developed to be used with 

cleaning agents supplied or recommended by the 

manufacturer. The use of any other cleaning agents or 

chemicals can negatively affect the safety of the device.

•  Cable connections should be kept dry and off the ground. 

Always uncoil the extension cable completely to avoid 

heat damage to the cable.

• Warning! Do not use the device when other persons or 

animals are in the near vicinity unless they are wearing 

appropriate protective clothing.

Carefully read and understand these instructions 

before operating this high pressure washer.
Package Contents (Fig.1)

 1. Main unit  

 2. Variable nozzle lance

 3. Mid nozzle lance

 4. Spray handle

 5. Spray handle hose

 (5m)

 6. Water connector

 7. Hose joint 

 8. Nozzle cleaning pin

 9. Foam nozzle

Technical data

Power rating input

800 W

Rated pressure

60 bar (6.0 MPa)

Allowable pressure 

90 bar (9.0 MPa)

Rated flow

4.8 L / min

Max. inlet water pressure 

1.0 MPa

Max. temperature: 

40

Adding water    

From a faucet      

Weight  

3.8 Kg

Sound pressure level

Uncertainty

LpA=76dB(A)

KPA=3dB

Sound power level

LwA=92dB(A)

Vibration Value

aH=1.8m/s

2

Kah=1.5m/s

2

Name of Parts:

  1. Main unit  

  2. Variable nozzle lance

  3. Mid nozzle lance

  4. Spray handle

  5. Spray handle hose

  6. Water connector

  7. Hose joint 

  8. Nozzle cleaning pin

  9. Foam nozzle

 10. Water supply hose (option)

 11. Hose clamp (option)

 12.  Main switch

 13. Safety lock button

 14.  Trigger

 15.  Power cord

 16.  Filter 

 17.  Water inlet

 18.  Release button

Содержание RYOBI AJP-800

Страница 1: ...69800384 00 KAP 04 20 AJP 800...

Страница 2: ...1 1 1 2 7 8 3 4 5 6 2 3 4 4 5 6 5 11 10 17 9 5 2 3 4 6...

Страница 3: ...2 A B B A 7 10 14 2 13 4 5 18 8 6 16 17 10 7 6 12 15 4 5 2 3 9 3 4 7 8 9 11 10 12 15 14 13 16...

Страница 4: ...ay Damaged parts must be immediately replaced by a qualified electrician Always pull the power plug out of the socket outlet before doing any work on the machine before changing the nozzle and wheneve...

Страница 5: ...ere there could be a danger of explosion If any doubt arises please contact our authorized distributor It is not allowed to clean asbestos containing surfaces with high pressure This machine must not...

Страница 6: ...sed flow The wide spray setting is useful for removing dirt from large areas washing cars etc Attaching the Foam Nozzle Fig 12 1 Fill the foam nozzle container with manufacturer recommended detergent...

Страница 7: ...pressure switch may result WARNING Confirm that the nozzle is free of debris by removing it from the spray handle and visually inspecting inside the opening Always clean the nozzle opening after remo...

Страница 8: ...seals are worn The filter is clogged Change the nozzle Check clean exchange Check and or exchange Check and or exchange Check and or clean There is excess noise Air is being drawn in The valves are w...

Страница 9: ...t saat ini RCD Level Keamanan Produk IPX5 P e r a t u r a n K e s e l a m a t a n U m u m d a n Pencegahan Kecelakaan Ini Penting bahwa Anda membaca peraturan keselamatan dan instruksi pengoperasian s...

Страница 10: ...dengan tekanan tinggi Mesin ini tidak boleh digunakan pada suhu dibawah 0 C Sambungan pasokan listrik misalnya koneksi kabel RCD atau memperbaiki dilakukan dengan kualifikasi dan mematuhi IEC60364 1 i...

Страница 11: ...r yang disemprot menyebar berfungsi untuk menghilangkan kotoran di area yang luas mencuci mobil dll Pemasangan Deterjen Nozzle Gbr 12 1 Isi wadah nozzle sabun dengan sabun pencuci yang di rekomendasik...

Страница 12: ...n dengan mengetuknya pada meja dan ujung noselnya ke bawah Jika nosel tersumbat tekanan air akan rendah dan mungkin akan menyebabkan kerusakan pada alat PERINGATAN pastikan bahwa nosel selalu dalam ke...

Страница 13: ...tersumbat Katup seal aus Seal aus Filter tersumbat Gantikan nosel Cek bersihkan ganti Cek dan atau ganti Cek dan ganti Cek dan bersihkan Terlalu bising Angin tertarik ke dalam Katup aus kotor atau te...

Страница 14: ...13...