3JF
1-3-13
Maintenance
Description
item No.
U607
(cont.)
Setting the mode for remote switching
Sets the signal detection method for remote switching. Be sure to change the setting according to the type of
telephone connected to the machine.
1. Enter 1 or 2 using the numeric keys to change the setting.
One-shot detection
Continuous detection
Display
1: ONE
2: CONT
Description
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the transmission intervals
Sets the minimum time required for connection to the line for the next transmission after the previous
transmission was completed. Change the setting if transmission problems occur during multi-transmission,
such as broadcasting and polling transmission, or reserved transmission.
1. Change the setting using the numeric keys.
10 s
30 s
70 s
120 s
Display
1: 10
2: 30
3: 70
4: 120
Description
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the loop current detection before dialing
Sets if the loop current detection is performed before dialing.
1. Enter 1 or 2 using the numeric keys to change the setting.
Performs loop current detection before dialing.
Does not perform loop current detection before dialing.
Display
1: ON
2: OFF
Description
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Setting the DIS signal to 4 bytes
Sets if bit 33 and later bits of the DIS/DTC signal are sent.
1. Enter 1 or 2 using the numeric keys to change the setting.
Bit 33 and later bits of the DIS/DTC signal are not sent.
Bit 33 and later bits of the DIS/DTC signal are sent.
Display
1: ON
2: OFF
Description
2. Press the start key. The value is set.
3. To return to the screen for selecting an item, press the stop/clear key.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No. is
displayed.