2PR
1-4-27
F040
Main PWB - Engine PWB communica-
tion error
Faulty connection
of the connector
between the main
PWB and engine
PWB.
Check the installation of the main PWB and
engine PWB and reinstall them if necessary
(See page 1-5-27 and 1-5-28).
Defective main
PWB.
Turn the power switch off/on to restart the
printer. If the error is not resolved, replace
main PWB (See page 1-5-27).
Defective engine
PWB.
Replace engine PWB (See page 1-5-28).
F050
Engine PWB ROM checksum error
Some error may
have occurred
when downloading
the firmware of the
engine PWB.
Download the firmware of the engine PWB
again using the memory card (See page 1-
6-2).
Defective engine
PWB.
Turn the power switch off/on to restart the
printer. If the error is not resolved, replace
engine PWB (See page 1-5-28).
F186
Main PWB video data control error
Defective main
PWB.
Turn the power switch off/on to restart the
printer. If the error is not resolved, replace
main PWB (See page 1-5-27).
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Содержание ECOSYS P7035cdn
Страница 1: ...SERVICE MANUAL Published in May 2014 842PR111 2PRSM061 Rev 1 ECOSYS P7035cdn...
Страница 4: ...This page is intentionally left blank...
Страница 10: ...This page is intentionally left blank...
Страница 14: ...2PR This page is intentionally left blank...
Страница 20: ...2PR 1 1 6 This page is intentionally left blank...
Страница 28: ...2PR 1 2 8 This page is intentionally left blank...
Страница 48: ...2PR 1 3 20 This page is intentionally left blank...
Страница 154: ...2PR 2 1 20 This page is intentionally left blank...
Страница 171: ...2PR 2 3 11 2 3 3 Paper exit PWB Figure 2 3 3 Paper exit PWB silk screen diagram PH1 YC4 YC3 YC2 YC6 YC5 YC7 YC8 YC1...
Страница 177: ......
Страница 178: ......