2J5
1-4-5
6000
Broken fuser heater lamp M wire
The temperature does not reach 100
°
C/
212
°
F after the fuser heater lamp M has
been turned on continuously for 30 s.
The detected temperature of fuser ther-
mistor M/S does not rise 1
°
C/1.8
°
F after
fuser heater lamp has been turned on
continuously for 15 s.
However, the signal will not be detected
when the detected temperature of fuser
thermistor M is 200
°
C/392
°
F or more.
Poor contact in the
fuser thermistor M
connector termi-
nals.
Reinsert the connector (See page P.1-5-21).
Fuser thermistor M
installed incor-
rectly.
Check and reinstall if necessary (See page
P.1-5-21).
Thermal cutout
triggered.
Check for continuity. If none, replace the
thermal cutout (See page P.1-5-21).
Fuser heater lamp
installed incor-
rectly.
Check and reinstall if necessary (See page
P.1-5-17).
Broken fuser
heater lamp wire.
Check for continuity. If none, replace the
fuser heater lamp M (See page P.1-5-17).
6020
Abnormally high fuser thermistor S
temperature
The temperature of the fuser thermistor
S detects 250
°
C/482
°
F or more continu-
ously for 3 s.
Shorted fuser ther-
mistor S.
Measure the resistance. If it is 0
Ω
, replace
the fuser thermistor S (See page P.1-5-21).
Defective engine
PWB.
Replace the engine PWB (See page P.1-5-
23).
6030
Broken fuser thermistor S wire
The detected temperature of fuser ther-
mistor S is 50
°
C/122
°
F or more and
input from fuser thermistor S is 1 less
than 1 (A/D value) continuously for 1.8
second.
Except when the fuser heater is turned
off.
Poor contact in the
fuser thermistor S
connector termi-
nals.
Reinsert the connector (See page P.1-5-21).
Broken fuser ther-
mistor S wire.
Measure the resistance. If it is
∞ Ω
, replace
the fuser thermistor S (See page P.1-5-21).
Fuser thermistor S
installed incor-
rectly.
Check and reinstall if necessary (See page
P.1-5-21).
Thermal cutout
triggered.
Check for continuity. If none, replace the
thermal cutout (See page P.1-5-21).
Fuser heater lamp
installed incor-
rectly.
Check and reinstall if necessary (See page
P.1-5-17).
Broken fuser
heater lamp wire.
Check for continuity. If none, replace the
fuser heater lamp M (See page P.1-5-17).
6220
Abnormally high fuser thermistor M
temperature
The temperature of the fuser thermistor
M detects 255
°
C/482
°
F or more continu-
ously for 3 s.
Shorted fuser ther-
mistor M.
Measure the resistance. If it is 0
Ω
, replace
the fuser thermistor M (See page P.1-5-21).
Defective engine
PWB.
Replace the engine PWB (See page P.1-5-
23).
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Содержание Ecosys FS-6970DN
Страница 1: ...SERVICE MANUAL Published in March 2009 842J5110 2J5SM060 First Edition FS 6970DN...
Страница 3: ...Revision history Revision Date Replaced pages Remarks...
Страница 4: ...This page is intentionally left blank...
Страница 10: ...This page is intentionally left blank...
Страница 18: ...2J5 1 1 6 This page is intentionally left blank...
Страница 24: ...2J5 1 2 6 This page is intentionally left blank...
Страница 40: ...2J5 1 3 16 This page is intentionally left blank...
Страница 120: ...2J5 2 3 8 This page is intentionally left blank...
Страница 124: ...2J5 2 4 4 This page is intentionally left blank...
Страница 125: ......
Страница 126: ......