Advanced Configuration
79
Figure 78 Access Rights Configuration
Read-Only Community
Range: 3~16 characters
Default: public
Function: Configure the name of read-only community.
Description: The MIB information of the switch can be read only if the community name
carried by an SNMP packet is identical with that configured on the switch.
Read-Write Community
Range: 3~16 characters
Default: private
Function: Configure the name of read-write community.
Description: The MIB information of the switch can be read and written only if the community
name carried by an SNMP packet is identical with that configured on the switch.
Request Port
Range: 1~65535
Default: 161
Function: Configure the number of the port for receiving SNMP requests.
3. Set trap parameters, as shown in the following figure.