Basic Configuration
23
100M&full duplex, 100M&half duplex, 1000M&full duplex, ot 1000M&half duplex.
1000M fiber ports can be set to auto-negotiation and 1000M&full duplex.
You are advised to enable auto-negotiation for each port to avoid the connection problems
caused by mismatched port configuration. If you want to force port speed/duplex mode,
please make sure the same speed/duplex mode configuration in the connected ports at both
ends.
Flow Control
Options: Off/On
Default: Off
Function: Enable/Disable flow control function on the designated port.
Description: Once the flow control function is enabled, the port will inform the sender to slow
the transmitting speed to avoid packet loss by algorithm or protocol when the port-received
flow is bigger than the size of port cache. If the devices work in different duplex modes
(half/full), their flow control is realized in different ways. If the devices work in full duplex
mode, the receiving end will send a special frame (Pause frame) to inform the sending end
to stop sending packets. When the sender receives the Pause frame, it will stop sending
packets for a period of "wait time" carried in the Pause frame and continue sending packets
once the "wait time" ends. If the devices work in half duplex mode, they support back
pressure flow control. The receiving end creates a conflict or a carrier signal. When the
sender detects the conflict or the carrier wave, it will take backoff to postpone the data
transmission.
RX
Options: Enable/Disable
Default: Enable
Function: Allow the port to receive data or not.
Description: Enable indicates the port can receive data; Disable indicates the port cannot
receive data.
TX
Содержание SICOM3024P
Страница 13: ...Product Introduction 6 management software and SNMP network monitoring...
Страница 25: ...Device Status 18 Figure 15 System Operating Information SICOM3024...
Страница 64: ...Advanced Configuration 57 Figure 60 Setting ACL Entry Parameters 2 Figure 61 Setting ACL Entry Parameters 3...
Страница 73: ...Advanced Configuration 66 Figure 67 Setting ACL Entry Parameters Group 2...
Страница 145: ...Advanced Configuration 138 Figure 137 Dynamic Unicast FDB Table...