Appendix A: Twisted-pair and Pin Distribution 

For  the  connection  of 10Base‐T/100Base‐TX,  the  twisted‐pair  must  have  two  pair  cable.  Each 
pair is distinguished with two different colors. For example, one strand is green, and the other is 
the alternate of green and white stripes. RJ‐45 connector should be equipped at both ends of the 
cable.     

                                                                                                                                                                               

             

 

 

Warning:   

Don’t insert a telephone plug into any RJ‐45 port. Only use twisted‐pair with RJ45 connectors at 
both ends conforming to FCC standard. 

                                                                 

                                                                                               

Fig.  A‐1  Shows  how  the  connector  of  RJ‐45  is  numbered  please  make  sure  that  the  inserting 
direction is correct. 

1

8

8

1

 

Figure A‐1 Connector of RJ‐45 

Pin

 

distribution

 

of

 

10Base

­

T/100Base

­

TX

 

Unshielded twisted‐ pair (UTP) or shielded twisted‐pair (STP) will be used for the connection of 
RJ‐45: for the connection of 10Mbps, category 3, 4 and 5 of 100 ohm will be used, and cat.5 of 
100 ohm will be used for 100Mbps. Additionally, do make sure that the connecting length of any 
twisted‐pair shall not exceed 100 meter. 

Port  of  RJ‐45  supports  automatic  MDI/MDI‐X  operation,  PC  or  server  may  be  connected  by 
straight‐through cable, or connect with other switch or hub. In straight‐through cable, pin 1, 2, 3 
and  6  at  one  end  of  the  cable  are  connected  to  pin  1,  2,  3  and  6  at  the  other  end  of  the 

Содержание SICOM3004

Страница 1: ...SICOM3004 SICOM3006 User s Manual 201105 1 SICOM3004 SICOM3006 Industrial Ethernet Switch User s Manual KYLAND Technology Co Ltd...

Страница 2: ...reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Publisher KYLAND Technology CO LTD Address Chongxin Creative Build...

Страница 3: ...ng contents Chapter 1 Overview and system features of SICOM3004 SICOM3006 Chapter 2 Performance and service functions of SIOCM3004 SICOM3006 Chapter 3 Hardware structure of SICOM3004 SICOM3006 Chapter...

Страница 4: ...g cases please immediately cut off the power supply and contact our company 1 Water gets into the equipments 2 Equipment damage or shell breakage 3 Abnormal operation conditions of equipment or the de...

Страница 5: ...5 Warning pay special attention to the notes behind the mark improper operation will lead to serious damage of the switch or injury of the operating personnel Caution attention danger remind the opera...

Страница 6: ...ervice Functions 11 Chapter 3 Hardware Structure 15 3 1 System Structure 15 3 2 System Explanation 16 Chapter 4 Hardware Installation 21 4 1 Installation requirement 21 Chapter 5 Test Methods 23 5 1 S...

Страница 7: ...tional ports which support self healing ring network In fiber or copper optional ports of SICOM3004 SICOM3006 if customer chooses fiber ports they will be compulsory to 100M full duplex supporting DT...

Страница 8: ...f input power ripple is less than 50mv and starting current is more than 3A 1 3 Packing list and unpacking check 1 Packing list The packing list includes the following items SICOM3004 SICOM3006 indust...

Страница 9: ...ser s Manual 201105 9 is missing or damaged please contact us Warning For the built in precise parts of the equipment please handle with care and avoid strenuous vibration to avoid affecting the perfo...

Страница 10: ...ng speed 1488100pps Switching mode Store and Forward System switching bandwidth 5 6G Electromagnetic compatibility interference EN55022 Electromagnetic compatibility immunity EN50082 2 TP port paramet...

Страница 11: ...standard 10 100Base TX Ethernet ports Each port has self adaptive function capable of automatically configuring between 10Base T and 100Base TX between full duplex and half duplex mode supporting MDI...

Страница 12: ...and DSCP priority configurations When the terminal connected to SICOM3004 SICOM3006 doesn t support these three priorities and user wants to set different priorities to services in different ports QoS...

Страница 13: ...dcast packets are transmitted in the network they will take up so much bandwidth that cause a network timeout It is called network storm SICOM3004 SICOM3006 support broadcast data packets multicast da...

Страница 14: ...stem adopt it because it is easy to be realized free and can be used to control various devices RMON RMON is a standard monitoring regulation used to switch the network monitoring data between network...

Страница 15: ...e 3 1 System Structure The hardware structure of SICOM3004 is as Figure 3 1 Figure 3 1 Hardware Structure of SICOM3004 FE1 FE2 2 10 100Base TX ports FX3 FX4 FE3 FE4 2 100Base FX ports or 2 10 100Base...

Страница 16: ...des TTL interface level to motherboard by pins RS232 interface circuit is implemented on motherboard Alarm Output OEM board has ring network fault self inspection and alarm functions When network brea...

Страница 17: ...1 LINK LED PIN number 13 14 15 16 Signal definition Port 1 SPEED LED Port 2 LINK LED Port 2 SPEED LED Port 3 LINK LED PIN number 17 18 19 20 Signal definition Port 3 SPEED LED fiber port doesn t has...

Страница 18: ...finition RXD3 port 3 TXD4 port 4 TXD4 port 4 RXD4 port 4 PIN number 9 10 11 12 Signal definition RXD4 port 4 FX0_SD SD signal of fiber port 1 FX1_SD SD signal of fiber port 2 GND Note The pins which d...

Страница 19: ...vel if the ring is disconnected they output low level when the switch is set to be slave in the ring the pin 21 and pin 22 output high level J6 J7 pin diagram and pin explanation for SICOM3006 These t...

Страница 20: ...ront view SICOM3004 Socket for J5 2 16p 2 54mm spacing two row socket with the height of 12mm Socket for J6 2 6p 2 54mm spacing two row socket with the height of 12mm SICOM3006 Socket for J5 2 16p 2 5...

Страница 21: ...n 4 1 Installation requirement SICOM3004 product mechanical drawing for installation is as below top view Dimension is 80mm 80mm The square pin is pin 1 SICOM3006 product mechanical drawing for instal...

Страница 22: ...s board the pins showed in above drawings are welding points That means the welding points are on front and the pins are on the reverse side Meanwhile SICOM3004 SICOM3006 s electrical space is big en...

Страница 23: ...mmand to each other If both of them receive complete command without packet loss and the corresponding yellow light of the port keep on PC work on 100M or keep off PC work on 10M and the corresponding...

Страница 24: ...mputer 1 select the Operation item input cmd WIN2000 or command WIN98 95 and send ping 192 168 100 11 l 1000 t 1 means the number of bytes of sending packets t means keep sending the data Operate the...

Страница 25: ...with the recovery time of less than 50ms SICOM3006 provides 4 downlink redundant 100Base FX SM MM fiber ports or 4 10 100Based TX RJ45 ports which can form 100M redundant ring network with the recover...

Страница 26: ...s and 2 redundant 100Base FX single mode or multimode fiber ports SICOM3006 industrial Ethernet switch is an integrative structure with the fixed configuration of 2 10 100Base TX RJ45 ports the option...

Страница 27: ...ctor of RJ 45 is numbered please make sure that the inserting direction is correct 1 8 8 1 Figure A 1 Connector of RJ 45 Pin distribution of 10Base T 100Base TX Unshielded twisted pair UTP or shielded...

Страница 28: ...e TX Pin MDI X signal name MDI signal name 1 Receiving data RD Output data TD 2 Receiving data RD Output data TD 3 Output data TD Receiving data RD 6 Output data TD Receiving data RD 4 5 7 8 Unused Un...

Страница 29: ...le B 1 Table B 1 Cable type and specification Cable Type Max length Connector 10Base T Cat 3 4 and 5 100ohm UTP 100m RJ 45 100Base TX Cat 5 100ohm UTP 100m RJ 45 100Base FX 50 125 or 62 5 125 m core m...

Страница 30: ...expresses the signaling rate which is defined as the change times of the status for the electric or optical transmission medium within 1 second Bridge One of network equipments which run on the layer...

Страница 31: ...006 User s Manual 201105 31 MDI It is the Medium Dependent Interface in which one Ethernet port is taken as the receiving terminal to connect to the port of other equipment MDI X Medium Dependent Inte...

Отзывы: