background image

SICOM3004/SICOM3006 User’s Manual 201105

 

- 14 - 

the  delay  time  from  blocking  to  forwarding  in  the  port  in  order  to  resume  the  network 
communication ASAP. 

ACL

   

ACL  (Access  Control  List)  use  protocols  to  define  the  access  rules  by  the  source  or  target  MAC 
addresses.  It  can  limit  the  network  traffic,  enhance  network  performance  and  control  the 
communication flow. ACL is the basic security method to network access. 

Alarm

 

Output

 

This  function  is  significant  for  the  real  time  transmission  of  device  alarms.  Alarm  function 
includes  port  alarm  and  ring  alarm  which  can  be  enabled  by  management  software.  The  alarm 
information is displayed on the network management interface. 

SNMP

 

SNMP

Simple

 

Network

 

Management

 

Protocol

offers  a  frame  structure  for  low  level 

network management. SNMP protocol is used widely. Many kinds of networking devices, software 
and  system  adopt  it  because  it  is  easy  to  be  realized,  free,  and  can  be  used  to  control  various 
devices. 

RMON

   

RMON is a standard monitoring regulation, used to switch the network monitoring data between 
network monitors and console system. It offers more selections for network operators to choose 
the  suitable  console  and  network  monitor  for  special  requirements.  It  is  a  supplementation  to 
SNMP  function  and  is  especially  useful  for  monitoring  and  managing  LAN.  The  purpose  of 
developing  RMON  is  to  provide  statistic  result  of  information  flow  and  analyze  network 
parameters so as to work out a comprehensive network diagnoses, plan and regulation.   

By  RMON,  users  can  do  operation  among  SNMP  management  stations  and  monitoring  agents. 
Furthermore, it can offer a standard for a group of MIB to collect the network statistics which is 
not available via SNMP. RMON realizes early network diagnoses by using powerful Alarm Group, 
which  allows  to  set  thresholds  for  key  network  parameters  so  as  to  automatically  send  alarm 
signal to central management console. 

 

 

 

Содержание SICOM3004

Страница 1: ...SICOM3004 SICOM3006 User s Manual 201105 1 SICOM3004 SICOM3006 Industrial Ethernet Switch User s Manual KYLAND Technology Co Ltd...

Страница 2: ...reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Publisher KYLAND Technology CO LTD Address Chongxin Creative Build...

Страница 3: ...ng contents Chapter 1 Overview and system features of SICOM3004 SICOM3006 Chapter 2 Performance and service functions of SIOCM3004 SICOM3006 Chapter 3 Hardware structure of SICOM3004 SICOM3006 Chapter...

Страница 4: ...g cases please immediately cut off the power supply and contact our company 1 Water gets into the equipments 2 Equipment damage or shell breakage 3 Abnormal operation conditions of equipment or the de...

Страница 5: ...5 Warning pay special attention to the notes behind the mark improper operation will lead to serious damage of the switch or injury of the operating personnel Caution attention danger remind the opera...

Страница 6: ...ervice Functions 11 Chapter 3 Hardware Structure 15 3 1 System Structure 15 3 2 System Explanation 16 Chapter 4 Hardware Installation 21 4 1 Installation requirement 21 Chapter 5 Test Methods 23 5 1 S...

Страница 7: ...tional ports which support self healing ring network In fiber or copper optional ports of SICOM3004 SICOM3006 if customer chooses fiber ports they will be compulsory to 100M full duplex supporting DT...

Страница 8: ...f input power ripple is less than 50mv and starting current is more than 3A 1 3 Packing list and unpacking check 1 Packing list The packing list includes the following items SICOM3004 SICOM3006 indust...

Страница 9: ...ser s Manual 201105 9 is missing or damaged please contact us Warning For the built in precise parts of the equipment please handle with care and avoid strenuous vibration to avoid affecting the perfo...

Страница 10: ...ng speed 1488100pps Switching mode Store and Forward System switching bandwidth 5 6G Electromagnetic compatibility interference EN55022 Electromagnetic compatibility immunity EN50082 2 TP port paramet...

Страница 11: ...standard 10 100Base TX Ethernet ports Each port has self adaptive function capable of automatically configuring between 10Base T and 100Base TX between full duplex and half duplex mode supporting MDI...

Страница 12: ...and DSCP priority configurations When the terminal connected to SICOM3004 SICOM3006 doesn t support these three priorities and user wants to set different priorities to services in different ports QoS...

Страница 13: ...dcast packets are transmitted in the network they will take up so much bandwidth that cause a network timeout It is called network storm SICOM3004 SICOM3006 support broadcast data packets multicast da...

Страница 14: ...stem adopt it because it is easy to be realized free and can be used to control various devices RMON RMON is a standard monitoring regulation used to switch the network monitoring data between network...

Страница 15: ...e 3 1 System Structure The hardware structure of SICOM3004 is as Figure 3 1 Figure 3 1 Hardware Structure of SICOM3004 FE1 FE2 2 10 100Base TX ports FX3 FX4 FE3 FE4 2 100Base FX ports or 2 10 100Base...

Страница 16: ...des TTL interface level to motherboard by pins RS232 interface circuit is implemented on motherboard Alarm Output OEM board has ring network fault self inspection and alarm functions When network brea...

Страница 17: ...1 LINK LED PIN number 13 14 15 16 Signal definition Port 1 SPEED LED Port 2 LINK LED Port 2 SPEED LED Port 3 LINK LED PIN number 17 18 19 20 Signal definition Port 3 SPEED LED fiber port doesn t has...

Страница 18: ...finition RXD3 port 3 TXD4 port 4 TXD4 port 4 RXD4 port 4 PIN number 9 10 11 12 Signal definition RXD4 port 4 FX0_SD SD signal of fiber port 1 FX1_SD SD signal of fiber port 2 GND Note The pins which d...

Страница 19: ...vel if the ring is disconnected they output low level when the switch is set to be slave in the ring the pin 21 and pin 22 output high level J6 J7 pin diagram and pin explanation for SICOM3006 These t...

Страница 20: ...ront view SICOM3004 Socket for J5 2 16p 2 54mm spacing two row socket with the height of 12mm Socket for J6 2 6p 2 54mm spacing two row socket with the height of 12mm SICOM3006 Socket for J5 2 16p 2 5...

Страница 21: ...n 4 1 Installation requirement SICOM3004 product mechanical drawing for installation is as below top view Dimension is 80mm 80mm The square pin is pin 1 SICOM3006 product mechanical drawing for instal...

Страница 22: ...s board the pins showed in above drawings are welding points That means the welding points are on front and the pins are on the reverse side Meanwhile SICOM3004 SICOM3006 s electrical space is big en...

Страница 23: ...mmand to each other If both of them receive complete command without packet loss and the corresponding yellow light of the port keep on PC work on 100M or keep off PC work on 10M and the corresponding...

Страница 24: ...mputer 1 select the Operation item input cmd WIN2000 or command WIN98 95 and send ping 192 168 100 11 l 1000 t 1 means the number of bytes of sending packets t means keep sending the data Operate the...

Страница 25: ...with the recovery time of less than 50ms SICOM3006 provides 4 downlink redundant 100Base FX SM MM fiber ports or 4 10 100Based TX RJ45 ports which can form 100M redundant ring network with the recover...

Страница 26: ...s and 2 redundant 100Base FX single mode or multimode fiber ports SICOM3006 industrial Ethernet switch is an integrative structure with the fixed configuration of 2 10 100Base TX RJ45 ports the option...

Страница 27: ...ctor of RJ 45 is numbered please make sure that the inserting direction is correct 1 8 8 1 Figure A 1 Connector of RJ 45 Pin distribution of 10Base T 100Base TX Unshielded twisted pair UTP or shielded...

Страница 28: ...e TX Pin MDI X signal name MDI signal name 1 Receiving data RD Output data TD 2 Receiving data RD Output data TD 3 Output data TD Receiving data RD 6 Output data TD Receiving data RD 4 5 7 8 Unused Un...

Страница 29: ...le B 1 Table B 1 Cable type and specification Cable Type Max length Connector 10Base T Cat 3 4 and 5 100ohm UTP 100m RJ 45 100Base TX Cat 5 100ohm UTP 100m RJ 45 100Base FX 50 125 or 62 5 125 m core m...

Страница 30: ...expresses the signaling rate which is defined as the change times of the status for the electric or optical transmission medium within 1 second Bridge One of network equipments which run on the layer...

Страница 31: ...006 User s Manual 201105 31 MDI It is the Medium Dependent Interface in which one Ethernet port is taken as the receiving terminal to connect to the port of other equipment MDI X Medium Dependent Inte...