SICOM3004/SICOM3006 User’s Manual 201105
- 23 -
Chapter 5: Test Methods
5.1
Self
inspection
When the equipment is powered on, all port indicators will blink one time, showing that ports are
working smoothly. The startup complete after 30 seconds and the RUN indicators will blink.
5.2
TP
Port
Test
As shown in Figure 5‐1, SICOM3004/SICOM3006 is powered on, then respectively connect two TP
ports in the switch to two test computers by straight‐through cables, and send the “ping”
command to each other. If both of them receive complete command without packet loss and the
corresponding yellow light of the port keep on (PC work on 100M) or keep off (PC work on 10M)
and the corresponding green light blink, they mean that these two TP ports are in good conditions.
Test other TP ports as the same way. The PING command example is as follows.
Figure 5‐1 TP port test
5.
3
Fiber
Port
Test
As shown in Figure 5‐2, firstly two units of SICOM3004/SICOM3006 are connected to a fiber chain
network. Then connect any RJ45 port in each switch with test computers by straight‐through
cables and send Ping command to each other. They can both get command without packet loss