6.
Replacement of commonly used accessories
6.5 Crawler belt replacement/severe wear or contamination
1.Lift the Kwun onto a flat surface, hold the center of the body, and leave the tracks in the air.
2. Unscrew the 9 bolts connecting the drive component wheel frame with Kwun-body.
3. Lift the wheel frame and take it out.
4. Remove the track and finish the track disassembly.
5. Replace crawler belt and start crawler belt installation.
6.
Pull one side of the track into the drive wheel gear ring, straighten it and put it into the other side, rotate slightly to install both sides.
7. Align the wheel frame with the Kwun-body bolt hole and tighten 9 bolts, and finish the installation.
6.6 Replacement /Damage of the central sucker
1.Prepare the M4 hex key, and erect the Kwun body.
2.Loosen the four bolts on the central suction cup and the four bolts on the pressure ring of the dust ring using an M4 hexagon
socket wrench.
3. Remove the dust jacket from the rotor of the rotary table.
4. Make use of the scalability of the new dust jacket to stretch the central through hole into the rotor and stator of the rotating table.
5. Put the pressure ring on the dust cover and press the dust cover on the body base and align with the screw hole.
6. Tighten the pressure ring on the dust cover and secure the dust cover to the base by inserting four bolts using an M4 hex key.
7. Connect the central sucker to the rotor hole of the rotary table, and tighten the four bolts using an M4 hex key.
* For more tutorials and videos on commonly used parts replacement methods, please visit the official website
6.7 Vacuum filter replacement / serious water accumulation or ash accumulation
1.After removing the battery, remove the vacuum filter from the vacuum filter holder.
2. Press the quick change pipe connector of the air inlet, and remove the air inlet pipe connected by the three-way
pagoda connector.
3. Press the quick change pipe connector of the air outlet and remove the air outlet pipe connected through the pagoda
connector.
4. Check the label of inlet and outlet of the shell of the new vacuum filter.
5. Press the outlet pipe directly connected to the pagoda connector into the outlet quick change pipe connector.
6. Press the air inlet pipe connected by the three-way pagoda connector into the quick change pipe connector of the air
inlet.
7. Clamp the vacuum filter into the vacuum filter holder.
30
Содержание Kwun Solarox B30M
Страница 33: ...8 Recommended Operating Conditions ROC 32 ...