K60x User Guide
K60x User Guide
39
8
Troubleshooting
8.1
How to Find the Original IP Address of the Unit
When direct access to a unit is needed after a factory reset or for direct configuration of a
new unit, the IP address is required.
All units are shipped with an original IP address which follows the IPv4 pattern of
169.254.#.#, where the last two octets are randomized. The units have a temporary label
listing the unit
s’ IP and MAC address. Keep this information in your records.
If the IP address is unavailable, go to
for help obtaining the original IP
address, using the Serial Number on the unit’s perman
ent label.
8.2
Factory Reset Instructions
The easiest way to reset to factory defaults is using the
Restore Factory Defaults
button
of the WebUI or the equivalent CLI command.
If you cannot access the WebUI or CLI because of a lost password, incorrect VLAN
configuration or the IP address has been changed to an unknown value, you can use a
reset cable as shown in the instructions below. Instructions for making a reset cable follow
the reset instructions.
Note:
Factory reset returns the unit’s login to the default: “Kwikbit”. Factory reset also
returns the IP address of the unit back to the original IP address.
To reset the device to factory defaults:
1.
Disconnect power by removing the connector in Port 1.
2.
Insert the reset cable into Ethernet Port 2.
3.
Reconnect power to Port 1. During power-up, observe the LED.
4.
The red and green repeating sequence indicates the K60x is resetting:
repeating.
5.
After the repeating LED sequence completes, remove the reset cable.
6.
The device is now operating at factory default settings.
Содержание K60x
Страница 1: ...K60x Wireless Communication System User Guide June 8 2021...