background image

 

K60x User Guide

 

 

14 

 

K60x User Guide 

 

 

 

Содержание K60x

Страница 1: ...K60x Wireless Communication System User Guide June 8 2021...

Страница 2: ...product which are not authorized by Kwikbit Inc could void your authority to operate this equipment THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITH...

Страница 3: ...x Unit Specifications 12 4 LED Indicator Codes 15 5 Installation 16 5 1 Prepare for Installation 17 5 2 Pre installation Setup and IP Configurations 18 5 3 Mounting and Connecting the K60x 24 6 Manage...

Страница 4: ...2 Factory Reset Instructions 39 9 Appendices 41 9 1 Acronyms 41 9 2 Terms 42 9 3 Regulatory Statements 43 9 3 1 FCC Radiation Exposure Statement 43 9 3 2 FCC Regulatory Statement 43 9 3 3 ISED Industr...

Страница 5: ...face CLI and Edge Controller are briefly described but detailed instruction is not provided It is assumed readers of this guide are familiar with Basic networking concepts Routing and switching in net...

Страница 6: ...K60x User Guide 6 K60x User Guide 1 2 Additional help Kwikbit is committed to providing our customers with high quality technical support Web support kwikbit com E mail support kwikbit com...

Страница 7: ...izontal 30 vertical help to ensure reliable connectivity and simplify installation of the units for non technical staff Generally a K60x network consists of the following components Hub s One or more...

Страница 8: ...rnet Switch IEEE 802 1d Each K60x cluster one hub with its group of up to eight remotes acts as a distributed switch with the Ethernet ports on the hub and linked remotes acting as switch ports The em...

Страница 9: ...distribution Network attributes Ethernet switch 802 1Q DSCP ToS 802 1p IPv4 v6 and 802 1ad QinQ tagging Network interfaces K60 Two GbE RJ 45 ports Port 1 with PoE in and Port 2 with up to 30W PoE outp...

Страница 10: ...Ethernet uplink and downlink combined throughput for a K60x link Throughput Performance for Cyclic Prefix of 1 8 MCS Index Modulation NCBPS Repetitions Code Rate Data Rate Mbit s 1 2 BPSK 1 2 1 2 310...

Страница 11: ...g The K60x has three RJ45 connector ports Port 1 is used for 2 5Gb Ethernet network connectivity and PoE power input 802 3at 802 3at or 802 3bt Port 2 is used for 2 5Gb Ethernet network connectivity a...

Страница 12: ...etworking specifications for the K60x Physical Characteristics General Single piece outdoor unit with integrated antenna Dimensions H x W x D 201 x 99 x 71 mm 7 9 x 3 9 x 2 8 inches Weight 992 g 2 lbs...

Страница 13: ...ons Operating temperature 30 C to 55 C Ingress Protection rating IP67 ESD IEC EN 61000 4 2 EMC IEC EN 61000 4 3 Radio Specifications Access technology Single carrier beamforming physical layer 802 11a...

Страница 14: ...K60x User Guide 14 K60x User Guide...

Страница 15: ...Operating normally as hub or root hub Flashing green Remote has no connection to a hub Example repeating Flashing green in groups of 1 5 Remote is connected to hub Number of flashes shows signal stre...

Страница 16: ...fic information Pre installation setup and IP configuration for systems not using Edge Controller o Setting device roles SSID and airlink passcode o Setting communication channel frequency for hubs o...

Страница 17: ...the site Record the IP and MAC address information found on the temporary peelable label on the K60x box The IP address will be used for direct configuration of the K60x Locate the permanent label on...

Страница 18: ...ditional settings and status information Typical settings for initial configuration of the K60x WebUI Tab Setting Comments Wireless Device Role Required SSID Required Airlink encryption passcode Requi...

Страница 19: ...one using one of the methods shown in the following graphic Tip Since the ports on the unit are weatherproof a standard RJ45 Ethernet plug will lock into place and be difficult to remove One option is...

Страница 20: ...rent from the example but will follow the pattern 169 254 See how to find the original IP address You may have to temporarily set your computer to obtain IP addresses automatically for direct access t...

Страница 21: ...ireless link with to up to eight remote devices Remote units form wireless links to only one hub at a time If a remote has more than one hub device within range the Preferred hub setting ensures that...

Страница 22: ...r Guide 4 On the Network tab change the IP assignment method as required by your organization s network policy Note When the IP address is changed be sure to record it for future access monitoring and...

Страница 23: ...al location where the device will be installed Description may include orientation function role or other information about the device Location and description information is useful when installing ma...

Страница 24: ...installation location for each K60x unit and whether it will be on a pole pipe or wall 2 For pipe or pole mounted units insert pipe clamps not supplied into the square holes in the back of the bracket...

Страница 25: ...ing the unit around the pole Adjust the downtilt angle of the unit using the slotted screw hole When aligned as desired tighten clamps and screws Tip When adjusting angles keep in mind that the antenn...

Страница 26: ...be purchased from store kwikbit com Repeat the process to connect cable to Port 2 as needed Use the Kwikbit supplied port caps to cover any unused ports 6 Optional install a ground wire if required U...

Страница 27: ...commands enabling the operator to manage maintain and troubleshoot the system via the command line Edge Controller optional Provides the same interactive display and settings as the WebUI for each uni...

Страница 28: ...ge with status information and settings on multiple tabs To directly access the K60x WebUI 1 Supply power to the K60x and connect it to your Internet enabled computer with a Cat5 or higher Ethernet ca...

Страница 29: ...in 3 Clicking any tab or the login button will prompt for a login The first time you log in use the default user name and password User Name kwikbit Password kwikbit Changing the password can be done...

Страница 30: ...followed by kwikbit followed by the unit s IPv4 IP address For example ssh kwikbit 169 254 2 225 Your unit s specific IP address will be different from this example but will follow the pattern 169 25...

Страница 31: ...able information commands Enter at the prompt To enter control mode to adjust settings Enter control at the prompt Then enter to list all control commands To end the CLI session Enter Exit on the comm...

Страница 32: ...ing a security certificate provided by Kwikbit Network planning installation and provisioning procedures are most efficiently performed using the Kwikbit Edge Controller In addition the Edge Controlle...

Страница 33: ...ame functions can be accessed through commands available using the CLI 7 1 Status Information The Status tab shows a summary of information about the unit its wireless and LAN connections and interfac...

Страница 34: ...equire a factory reset using a reset cable Upgrade Firmware updates the device firmware with the upgrade version you select Change Password Use this button to change the password according to your org...

Страница 35: ...ude Remote Hub Root hub and Remote seekroot Preferred Hub can be set for remote units to prevent them from connecting with any other hubs that may be in range However if the preferred hub becomes unav...

Страница 36: ...gned when a root hub is defined on the network Assigning a remote_seekroot role on a network without a root hub will cause the remote to periodically disconnect scan and reconnect causing an intermitt...

Страница 37: ...K60x User Guide K60x User Guide 37 7 4 LAN The LAN tab displays information about the current LAN connections to the unit...

Страница 38: ...User Guide 38 K60x User Guide 7 5 Network The Network tab offers settings for Network Interfaces VLAN configuration and Port Isolation as well as additional Layer 2 SNMP and Network Services Configura...

Страница 39: ...s button on the Admin tab of the WebUI or the equivalent CLI command If you cannot access the WebUI or CLI because of a lost password incorrect VLAN configuration or the IP address has been changed to...

Страница 40: ...e cable and separate the wires for pin 1 and 2 For straight through T568B pinout wiring this is the orange white and orange pair 3 Short out the pin 1 and pin 2 pair of wires by stripping the insulati...

Страница 41: ...trostatic Discharge FCC Federal Communications Commission Gbps Gigabits per second GHz Gigahertz IEEE Institute of Electrical and Electronics Engineers ISED Innovation Science and Economic Development...

Страница 42: ...to a hub In the tree topology a remote may be on a leaf in the tree or may be where the tree branches out a site with a remote and one or more hubs Remote seekroot A device role in the Kwikbit network...

Страница 43: ...s equipment complies with IC RSS 102 radiation exposure limits set forth for an uncontrolled environment A minimum of 30 centimeters of separation between the K60x and all persons shall be maintained...

Страница 44: ...ide tout brouillage radioe lectrique subi me me si le brouillage est susceptible d encompromettre le fonctionnement Cet appareil ne doit pas tre utilis bord d un avion sauf dans les conditions num r e...

Отзывы: