- 17 -
•
Always use the fuel strainer.
•
Fill the fuel tank slightly less than the FULL tank.
6-4. Checking Fuel, Engine Oil and Water Leakage
Warning: Fire
•
Do not use this equipment when a leak is found. Repair the equipment before
use.
Be sure to check any leakage for fuel, oil and coolant/water at the hose
connections by opening side doors. Whenever checking any fuel leakage, turn the
fuel lever OPEN and be sure to close the fuel lever after checking.
6-5. Checking Battery
Caution: Injury to Eyes and Skin
•
Battery fluid contains diluted sulfuric acid. Avoid contact with eyes, skin or
clothing.
•
If the acid comes to contact, especially with eyes, flush with a lot of water, and
contact your physician immediately.
Caution: Explosion
•
Do not use the equipment or charge the battery, in the case the battery fluid level
is lower than the LOWER level.
•
Battery may emit some combustible gas, so keep it away from fire and sparks.
Caution: Explosion
•
Battery may emit some combustible gas, so keep it away from fire and sparks.
1) Check the fluid level. If the level is near or lower than LOWER level, add
distilled water until the fluid level reaches UPPER level.
2) Make sure that the battery cables are firmly secured to the posts. Tighten the
clamps if necessary.
<<<<
Note
>>>>
•
Check the hydrometer of the battery fluid. If it falls below 1.23, the battery requires
recharging. Please consult with our authorized distributor or our engineering
section.
TANK CAP
FUEL STRAINER
FUEL INLET